Corcym Inc.

FDA Registration(s)#

Registration, FEI, Name table
RegistrationFEINameStatusInitial importerExpiration yearAddress
30198929833019892983Corcym Inc.1Y2026-01-019800 Mount Pyramid Court, Suite #400 Englewood CO US 80112

Registered Device Listings#

Registration key, Listing key, Premarket submission table
Registration keyListing keyPremarket submissionDeviceProduct codeDecision date
2951741744467071K171431HAART 200 Aortic Annuloplasty Device 19mm, HAART 200 Aortic Annuloplasty Device 21mm, HAART 200 Aortic Annuloplasty Device 23mm, HAART 200 Aortic Annuloplasty Device 25mmPST2017-08-10
2951742014115385K163608HAART 300 Aortic Annuloplasty Device 19mm, HAART 300 Aortic Annuloplasty Device 21mm, HAART 300 Aortic Annuloplasty Device 23mm, HAART 300 Aortic Annuloplasty Device 25mmPST2017-03-21

Product Codes Associated With Registrations#

Product code, Registration listing records, Latest decision table
Product codeRegistration listing recordsLatest decision
PST22017-08-10

PMA#

Perceval Sutureless Heart Valve

2022-11-21

CORCYM Canada Corp.5005 North Fraser Wayburnaby V5J 5 PMA NumberP150011 Supplement NumberS026 Date Received10/24/2022 Decision Date11/21/2022 Product Code LWR  Advisory Committee Cardiovascular Supplement Type30-day Notice Supplement Reason Process Change -...

Solo Smart Heart Valve

2022-07-28

CORCYM Canada Corp.5005 North Fraser Wayburnaby V5J 5 PMA NumberP130011 Supplement NumberS011 Date Received06/29/2022 Decision Date07/28/2022 Product Code LWR  Advisory Committee Cardiovascular Supplement Type30-day Notice Supplement Reason Process Change -...

Solo Smart Stentless Heart Valve

2022-03-07

CORCYM Canada Corp.5005 North Fraser Wayburnaby V5J 5 PMA NumberP130011 Supplement NumberS010 Date Received03/03/2022 Decision Date03/07/2022 Product Code LWR  Advisory Committee Cardiovascular Supplement Type30-day Notice Supplement Reason Process Change -...

PMN#

GUDID#

DeTACH Aortic Cross Clamp Delivery Device - The DeTACH Detachable Aortic Cross Clamp Head device is a detachable cross clamp head used for temporary or partial occlusion of blood vessels during cardiovascular procedures. The jaws of the device are covered with autraumatic flexible tissue-engagement pads. The upper jaw pivots independently in relation to the pivot jaw actuator arm and the lower/fixed jaw to allow for parralel closure at distances between 5mm and less. The clamp head also incorporates a cam style locking mechanism to lock the jaws in the closed position after dethachment from the delivery device. The DeTACH Detachable Aortic Cross Clamp Head device utilizes the DeTACH Delivery Device

CORCYM SRL

2026-02-03

DeTACH Aortic Cross Clamp Quick Release Device - The DeTACH Detachable Aortic Cross Clamp Head device is a detachable cross clamp head used for temporary or partial occlusion of blood vessels during cardiovascular procedures. The jaws of the device are covered with autraumatic flexible tissue-engagement pads. The upper jaw pivots independently in relation to the pivot jaw actuator arm and the lower/fixed jaw to allow for parralel closure at distances between 5mm and less. The clamp head also incorporates a cam style locking mechanism to lock the jaws in the closed position after dethachment from the delivery device. The DeTACH Detachable Aortic Cross Clamp Head device utilizes the DeTACH Quick Release.

CORCYM SRL

2026-02-03

DeTACH Aortic Cross Clamp Head-Small - The DeTACH Detachable Aortic Cross Clamp Head device is a detachable cross clamp head used for temporary or partial occlusion of blood vessels during cardiovascular procedures. The jaws of the device are covered with autraumatic flexible tissue-engagement pads. The upper jaw pivots independently in relation to the pivot jaw actuator arm and the lower/fixed jaw to allow for parralel closure at distances between 5mm and less. The clamp head also incorporates a cam style locking mechanism to lock the jaws in the closed position after dethachment from the delivery device. The DeTACH Detachable Aortic Cross Clamp Head device is available in small, medium and large sizes (55mm, 65mm and 85mm tissue engagement pads respectively) which are packaged and distributed separately. The DeTACH Detachable Aortic Cross Clamp Head device utilizes the DeTACH Delivery Device

CORCYM SRL

2026-02-03

DeTACH Aortic Cross Clamp Head- Medium - The DeTACH Detachable Aortic Cross Clamp Head device is a detachable cross clamp head used for temporary or partial occlusion of blood vessels during cardiovascular procedures. The jaws of the device are covered with autraumatic flexible tissue-engagement pads. The upper jaw pivots independently in relation to the pivot jaw actuator arm and the lower/fixed jaw to allow for parralel closure at distances between 5mm and less. The clamp head also incorporates a cam style locking mechanism to lock the jaws in the closed position after dethachment from the delivery device. The DeTACH Detachable Aortic Cross Clamp Head device is available in small, medium and large sizes (55mm, 65mm and 85mm tissue engagement pads respectively) which are packaged and distributed separately. The DeTACH Detachable Aortic Cross Clamp Head device utilizes the DeTACH Delivery Device

CORCYM SRL

2026-02-03

DeTACH Aortic Cross Clamp Head-Large - The DeTACH Detachable Aortic Cross Clamp Head device is a detachable cross clamp head used for temporary or partial occlusion of blood vessels during cardiovascular procedures. The jaws of the device are covered with autraumatic flexible tissue-engagement pads. The upper jaw pivots independently in relation to the pivot jaw actuator arm and the lower/fixed jaw to allow for parralel closure at distances between 5mm and less. The clamp head also incorporates a cam style locking mechanism to lock the jaws in the closed position after dethachment from the delivery device. The DeTACH Detachable Aortic Cross Clamp Head device is available in small, medium and large sizes (55mm, 65mm and 85mm tissue engagement pads respectively) which are packaged and distributed separately. The DeTACH Detachable Aortic Cross Clamp Head device utilizes the DeTACH Delivery Device

CORCYM SRL

2026-02-03

TIE Intracorporeal Knot Placement Assist and COLLAR Papillary Muscle Exposure - The TIE device is a tourniquet-style surgical instrument used to control the target location of knot seating during precise suture knot tying and delivery applications. The COLLAR device is a flexible surgical retractor designed to retract valve leaflet tissue when inserted within the valve annulus. The device consists of a main body component which extends laterally to become the retraction wings. The distal tips of the retraction wings are bifurcated for additional tissue traction. The posterior aspect of the device has a stiffening rib along the superior border and a stabilization flange along the inferior border. The COLLAR device is available in 2 sizes (small and large) which are packaged together in a disposable set with the TIE device.

CORCYM SRL

2026-02-03

SUTURE BELT Circumferential Suture Organizer - The Suture Belt device is a circumferential surgical suture organizer that mounts to a retractor rack prior to use. The device incorporates a rigid base frame with 24 flexible holding plug inserts that receive and retain suture pairs. Suture retention is achieved by pressing the suture strands into the compression slots found between the rigid base frame and flexible holding plug inserts. The rigid base frame consists of 2 hinged halves which allow for angle adjustment of the individual segments. The attachment arms allow the device to be mounted to the retractor arms. Two spacer components allow the attachment arm height to be adjusted. The device is secured into the desired orientation and segment angle positioning by tightening the immobilizing thumb screws.

CORCYM SRL

2026-02-03

CUFF Aortic Root Exposure Device - The CUFF device is a flexible surgical retractor designed for exposure and access purposes when inserted into the aortic root and used to retract aortic wall tissue. The device consists of a main body component with retraction wings which are two-tiered and extend laterally. The posterior aspect of the device has a stabilization flange along the inferior border. Two alignment suture eyelet holes can be found within the medial portion of the stabilization flange.

CORCYM SRL

2026-02-03

DeTACH Aortic Cross Clamp Head-Small - The DeTACH Detachable Aortic Cross Clamp Head device is a detachable cross clamp head used for temporary or partial occlusion of blood vessels during cardiovascular procedures. The jaws of the device are covered with autraumatic flexible tissue-engagement pads. The upper jaw pivots independently in relation to the pivot jaw actuator arm and the lower/fixed jaw to allow for parralel closure at distances between 5mm and less. The clamp head also incorporates a cam style locking mechanism to lock the jaws in the closed position after dethachment from the delivery device. The DeTACH Detachable Aortic Cross Clamp Head device is available in small, medium and large sizes (55mm, 65mm and 85mm tissue engagement pads respectively) which are packaged and distributed separately. The DeTACH Detachable Aortic Cross Clamp Head device utilizes the DeTACH Delivery Device

CORCYM SRL

2026-02-03

DeTACH Aortic Cross Clamp Head-Large - The DeTACH Detachable Aortic Cross Clamp Head device is a detachable cross clamp head used for temporary or partial occlusion of blood vessels during cardiovascular procedures. The jaws of the device are covered with autraumatic flexible tissue-engagement pads. The upper jaw pivots independently in relation to the pivot jaw actuator arm and the lower/fixed jaw to allow for parralel closure at distances between 5mm and less. The clamp head also incorporates a cam style locking mechanism to lock the jaws in the closed position after dethachment from the delivery device. The DeTACH Detachable Aortic Cross Clamp Head device is available in small, medium and large sizes (55mm, 65mm and 85mm tissue engagement pads respectively) which are packaged and distributed separately. The DeTACH Detachable Aortic Cross Clamp Head device utilizes the DeTACH Delivery Device

CORCYM SRL

2026-02-03

TIE Intracorporeal Knot Placement Assist and COLLAR Papillary Muscle Exposure - The TIE device is a tourniquet-style surgical instrument used to control the target location of knot seating during precise suture knot tying and delivery applications. The COLLAR device is a flexible surgical retractor designed to retract valve leaflet tissue when inserted within the valve annulus. The device consists of a main body component which extends laterally to become the retraction wings. The distal tips of the retraction wings are bifurcated for additional tissue traction. The posterior aspect of the device has a stiffening rib along the superior border and a stabilization flange along the inferior border. The COLLAR device is available in 2 sizes (small and large) which are packaged together in a disposable set with the TIE device.

CORCYM SRL

2026-02-03

SUTURE BELT Circumferential Suture Organizer - The Suture Belt device is a circumferential surgical suture organizer that mounts to a retractor rack prior to use. The device incorporates a rigid base frame with 24 flexible holding plug inserts that receive and retain suture pairs. Suture retention is achieved by pressing the suture strands into the compression slots found between the rigid base frame and flexible holding plug inserts. The rigid base frame consists of 2 hinged halves which allow for angle adjustment of the individual segments. The attachment arms allow the device to be mounted to the retractor arms. Two spacer components allow the attachment arm height to be adjusted. The device is secured into the desired orientation and segment angle positioning by tightening the immobilizing thumb screws.

CORCYM SRL

2026-02-03

CUFF Aortic Root Exposure Device - The CUFF device is a flexible surgical retractor designed for exposure and access purposes when inserted into the aortic root and used to retract aortic wall tissue. The device consists of a main body component with retraction wings which are two-tiered and extend laterally. The posterior aspect of the device has a stabilization flange along the inferior border. Two alignment suture eyelet holes can be found within the medial portion of the stabilization flange.

CORCYM SRL

2026-02-03

80 records. Showing 1-40. Next