RAPID MEDICAL INC.

Matched from indexed company URL: Rapid Medical Ltd.

FDA Registration(s)#

Registration, FEI, Name table
RegistrationFEINameStatusInitial importerExpiration yearAddress
30155317233015531723RAPID MEDICAL INC.1Y2026-01-01445 South Kimball Avenue Suite 140 Southlake TX US 76092

GUDID Contact Samples#

Sampled from matched GUDID device records for this company; this is not an exhaustive company contact directory.

Source GUDID, Product, Phone table
Source GUDIDProductPhoneEmail
07290015107266Tigertriever Revascularization Device - The Tigertriever device is a stentriever that is comprised of an adjustable nitinol braided mesh, stainless steel shaft, nitinol core wire and a handle. The shaft connects the mesh and the handle by the core wire that runs inside the shaft from the distal end of the mesh to the slider activation element in the handle. The mesh is expanded when the physician pulls the slider, since the wires of the mesh are completely radiopaque, the physician sees the mesh under fluoroscopy and controls it until it conforms to the vessel diameter. The design of the wire mesh is optimized to penetrate the clot and encapsulate it during retrieval. Two versions of the device are available. The standard version Tigertriever (TRPP7155) has a net length of 32mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.021 inches. The shorter version Tigertriever 17 (TRPP7166) has a net length of 23 mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.017 inches. The Tigertriever is provided with a 3.5 Fr peelable loading sheath.+972722503331orit@rapid-medical.com
07290015107273Tigertriever 17 Revascularization Device - The Tigertriever device is a stentriever that is comprised of an adjustable nitinol braided mesh, stainless steel shaft, nitinol core wire and a handle. The shaft connects the mesh and the handle by the core wire that runs inside the shaft from the distal end of the mesh to the slider activation element in the handle. The mesh is expanded when the physician pulls the slider, since the wires of the mesh are completely radiopaque, the physician sees the mesh under fluoroscopy and controls it until it conforms to the vessel diameter. The design of the wire mesh is optimized to penetrate the clot and encapsulate it during retrieval. Two versions of the device are available. The standard version Tigertriever (TRPP7155) has a net length of 32mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.021 inches. The shorter version Tigertriever 17 (TRPP7166) has a net length of 23 mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.017 inches. The Tigertriever is provided with a 3.5 Fr peelable loading sheath.+972722503331orit@rapid-medical.com

Registered Device Listings#

Registration key, Listing key, Premarket submission table
Registration keyListing keyPremarket submissionDeviceProduct codeDecision date
2310751052487798K253062Tigertriever 25 Revascularization DeviceNRY2026-03-12
2310751979512278K251603Tigertriever 17 Ultra Revascularization DeviceNRY2025-10-06
2310751731675735K233791Drivewire 24 GuidewireMOF2024-07-11
2310751835152560K230429Tigertriever 21 Revascularization Device, Tigertriever 17 Revascularization Device, Tigertriever 13 Revascularization DeviceNRY2023-04-17
2310751967777630K220808Tigertriever 13 Revascularization DeviceNRY2022-07-25
2310751296681072K203625Numen Coil Embolization System; NumenFR Detachment SystemHCG2021-09-01
2310751178430474K203592Tigertriever and Tigertriever 17 Revascularization DevceNRY2021-03-23
2310751939797002K200374Columbus GuidewireMOF2020-12-14
2310751582145977DEN230064BraidE Embolization Assist DeviceQZU2024-02-21
2310751897862302DEN170064Comaneci, Comaneci Petit, Comaneci 17PUU2019-04-24

Product Codes Associated With Registrations#

Product code, Registration listing records, Latest decision table
Product codeRegistration listing recordsLatest decision
NRY52026-03-12
MOF22024-07-11
QZU12024-02-21
HCG12021-09-01
PUU12019-04-24

PMN#

GUDID#

Tigertriever 13 Revascularization Device - The Tigertriever 13 device is a stentriever that is comprised of an adjustable nitinol braided mesh, stainless steel shaft, nitinol core wire and a handle. The shaft connects the mesh and the handle by the core wire that runs inside the shaft from the distal end of the mesh to the slider activation element in the handle. The mesh is expanded when the physician pulls the slider, since the wires of the mesh are completely radiopaque, the physician sees the mesh under fluoroscopy and controls it until it conforms to the vessel diameter. The design of the wire mesh is optimized to penetrate the clot and encapsulate it during retrieval. The Tigertriever 13 Revascularization Device is supplied sterile and is intended for single-use only by physicians trained in neuro-interventional catheterization and the treatment of ischemic stroke.

RAPID MEDICAL LTD

2022-07-28

Tigertriever Revascularization Device - The Tigertriever device is a stentriever that is comprised of an adjustable nitinol braided mesh, stainless steel shaft, nitinol core wire and a handle. The shaft connects the mesh and the handle by the core wire that runs inside the shaft from the distal end of the mesh to the slider activation element in the handle. The mesh is expanded when the physician pulls the slider, since the wires of the mesh are completely radiopaque, the physician sees the mesh under fluoroscopy and controls it until it conforms to the vessel diameter. The design of the wire mesh is optimized to penetrate the clot and encapsulate it during retrieval. Two versions of the device are available. The standard version Tigertriever (TRPP7155) has a net length of 32mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.021 inches. The shorter version Tigertriever 17 (TRPP7166) has a net length of 23 mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.017 inches. The Tigertriever is provided with a 3.5 Fr peelable loading sheath.

RAPID MEDICAL LTD

2021-04-05

Tigertriever 17 Revascularization Device - The Tigertriever device is a stentriever that is comprised of an adjustable nitinol braided mesh, stainless steel shaft, nitinol core wire and a handle. The shaft connects the mesh and the handle by the core wire that runs inside the shaft from the distal end of the mesh to the slider activation element in the handle. The mesh is expanded when the physician pulls the slider, since the wires of the mesh are completely radiopaque, the physician sees the mesh under fluoroscopy and controls it until it conforms to the vessel diameter. The design of the wire mesh is optimized to penetrate the clot and encapsulate it during retrieval. Two versions of the device are available. The standard version Tigertriever (TRPP7155) has a net length of 32mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.021 inches. The shorter version Tigertriever 17 (TRPP7166) has a net length of 23 mm (unexpanded form) and it is delivered through a microcatheter with an internal diameter of 0.017 inches. The Tigertriever is provided with a 3.5 Fr peelable loading sheath.

RAPID MEDICAL LTD

2021-04-05

Tigertriever 13 Revascularization Device - The Tigertriever 13 device is a stentriever that is comprised of an adjustable nitinol braided mesh, stainless steel shaft, nitinol core wire and a handle. The shaft connects the mesh and the handle by the core wire that runs inside the shaft from the distal end of the mesh to the slider activation element in the handle. The mesh is expanded when the physician pulls the slider, since the wires of the mesh are completely radiopaque, the physician sees the mesh under fluoroscopy and controls it until it conforms to the vessel diameter. The design of the wire mesh is optimized to penetrate the clot and encapsulate it during retrieval. The Tigertriever 13 Revascularization Device is supplied sterile and is intended for single-use only by physicians trained in neuro-interventional catheterization and the treatment of ischemic stroke.

RAPID MEDICAL LTD

2022-07-28