INDICLOR- indium chloride in-111 solution
Medi-Physics Inc.
----------
High Purity Indium Chloride In-111 Sterile Solution
Diagnostic—For use in Radiolabeling
ProstaScint and Zevalin
For single dose, single use only
INDICLOR Indium In-111 Chloride is a diagnostic radiopharmaceutical intended for radiolabeling ProstaScint (capromab pendetide) used for in vivo diagnostic imaging procedures and for radiolabeling Zevalin (ibritumomab tiuxetan) in preparations used for radioimmunotherapy procedures. It is supplied as a sterile, pyrogen-free solution of Indium (111In) Chloride in 0.04M HCl. Each milliliter is supplied at a radioactive concentration of 370 MBq, 10 mCi of Indium In-111 Chloride at time of calibration (no carrier added, with specific activity of > 1.85 GBq/µg Indium, > 50 mCi/µg Indium at time of calibration). The pH of the solution is about 1.4.
A Cadmium Cd-112 enriched target is bombarded in a cyclotron to produce Indium In-111 by the (p,2n) reaction. The bombardment conditions, the energy of the proton beam and the length of the bombardment are chosen to ensure an Indium In-111 yield of high radionuclidic purity. Radionuclidic purity is checked at release particularly for the presence of Indium In-114. The relative proportion of this impurity increases, after release of the batch, as a result of its longer half-life. Because of its beta-emitting component and its potentially high organ dose contribution, Indium In-114m is particularly important if present above carefully controlled levels.
Release specifications:
Indium In-111 decays by electron capture with a physical half-life of 67.2 hours (2.8 days). The energies of the photons that are useful for detection and imaging studies are listed in Table 1.
Radiation | Mean%/Disintegration | Mean Energy (keV) |
---|---|---|
|
||
Gamma 2 | 90.2 | 171.3 |
Gamma 3 | 94 | 245.4 |
The exposure rate constant for 37 MBq, 1 mCi Indium In-111 is 8.3 × 10-4 C/kg/hr, 3.21 R/hr at 1 cm. The first half value thickness of lead (Pb) for Indium In-111 is 0.023 cm. A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from the interposition of various thicknesses of Pb is shown in Table 2. For example, the use of 0.834 cm of lead will decrease the external radiation exposure by a factor of about 1,000.
Shield Thickness (Pb) cm | Coefficient of Attenuation |
---|---|
|
|
0.023 | 0.5 |
0.203 | 10-1 |
0.513 | 10-2 |
0.834 | 10-3 |
1.12 | 10-4 |
These estimates of attenuation do not take into consideration the presence of longer-lived contaminants with higher energy photons, namely Indium In-114m/114.
To allow correction for physical decay of Indium In-111, the fractions that remain at selected intervals before and after the time of calibration are shown in Table 3.
Hours | Fraction Remaining | Hours | Fraction Remaining |
---|---|---|---|
|
|||
-48 | 1.64 | 18 | 0.83 |
-42 | 1.54 | 24 | 0.78 |
-36 | 1.44 | 30 | 0.74 |
-30 | 1.36 | 36 | 0.69 |
-24 | 1.28 | 42 | 0.65 |
-18 | 1.20 | 48 | 0.61 |
-12 | 1.13 | 54 | 0.58 |
-6 | 1.06 | 60 | 0.54 |
0* | 1.00 | 66 | 0.51 |
6 | 0.94 | 72 | 0.48 |
12 | 0.88 |
Please refer to the package insert for ProstaScint or Zevalin for this information on the final drug product.
INDICLOR Indium In-111 Chloride is indicated for radiolabeling of ProstaScint (capromab pendetide) in preparations used for in vivo diagnostic imaging procedures. Indiclor is also indicated for radiolabeling Zevalin (ibritumomab tiuxetan) in preparations used for radioimmunotherapy procedures. Please refer to the package insert for ProstaScint or Zevalin for information regarding the radiolabeled product.
Please refer to the package insert for ProstaScint or Zevalin for this information on the final drug product.
The contents of the vial of INDICLOR Indium In-111 Chloride solution are intended only to be used as an ingredient for radiolabeling ProstaScint used for in vivo diagnostic imaging procedures and for radiolabeling Zevalin in preparations used for radioimmunotherapy procedures.
Indiclor is not to be administered directly to humans.
Strict aseptic techniques should be used to maintain sterility throughout the procedures for using this product.
Do not use after the expiration time and date stated on the label.
The contents of the vial are radioactive. Adequate shielding must be maintained at all times.
Please refer to the package insert for ProstaScint or Zevalin for this information on the final drug product.
Please refer to the package insert for ProstaScint or Zevalin for this information on the final drug product.
Please refer to the package insert for ProstaScint or Zevalin for this information on the final drug product.
Please refer to the package insert for ProstaScint or Zevalin for this information on the final drug product.
Please refer to the package insert for ProstaScint or Zevalin for this information on the final drug product.
Please refer to the package insert for ProstaScint or Zevalin for this information on the final drug product.
This product is terminally sterilized by autoclave. Apyrogenicity is confirmed before release by a Limulus test.
INDICLOR Indium-111 Chloride is supplied in a 2 mL vial containing 0.5 milliliters, 185 MBq, 5.0 mCi of Indium In-111 at calibration time. This packaging design has been carefully selected to minimize leaching of cationic and anionic impurities into the product during transport and storage.
NDC: 17156-523-01
Store at room temperature 15°-25°C (59°-77°F).
This preparation is approved for use by persons licensed by the Illinois Emergency Management Agency pursuant to 32 IL. Adm. Code Section 330.260(a) and 335.4010 or equivalent licenses of the Nuclear Regulatory Commission or an Agreement State.
It is recommended that the vial be kept inside its transportation shield whenever possible and that it be handled with forceps when doses are being removed.
INS.1PA — Wednesday Calibration
INS.1PAF — Saturday Calibration
ProstaScint® is a registered trademark of EUSA Pharma (USA), Inc.
Zevalin® is a registered trademark of Spectrum Pharmaceuticals, Inc.
Manufactured by:
GE Healthcare
Medi-Physics, Inc.
Arlington Heights, IL 60004 U.S.A.
Customer Service: 1-800-292-8514
Professional Services: 1-800-654-0118
INDICLOR is a trademark of GE Healthcare.
GE and the GE Monogram are trademarks of General Electric Company.
© 2013 General Electric Company - All rights reserved.
43-0523
Revised April 2013
Product Codes: INS. 1PA/INS. 1PAF
GE Healthcare
INDICLOR™ Indium (111 In) Chloride
GE
1NS1PA
Rx ONLY. Sterile, Non-pyrogenic Solution in 0.04M HCl
NOT FOR DIRECT ADMINISTRATION.
Do not use after 3 days from Reference date. No carrier added.
Storage: Ambient Temperature 15°-25°C (59°-77°F).
For use when radiolabeling Monoclonal Antibodies. Refer to package insert.
185 MBq, 5 mCi, 370 MBq/mL 10 mCi/mL at 0600hrs CST on reference
0.5mL Single Dose vial <0.2 µg ln/mL
Mfd by: GE Healthcare, Medi-Physics, Inc., Arlington Heights, IL 60004 U.S.A.
41-0523
INDICLOR
indium chloride in-111 solution |
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
||||||||||||||||||||
|
Labeler - Medi-Physics Inc. (095263729) |