{"adverse_reactions":["Adverse Reactions No adverse reactions were reported in clinical trials."],"carcinogenesis_and_mutagenesis_and_impairment_of_fertility":["Carcinogenesis, mutagenesis, impairment of fertility No studies have been conducted with 14 C-urea to evaluate its potential for carcinogenicity, impairment of fertility, or mutagenicity."],"clinical_pharmacology":["Clinical Pharmacology The urease enzyme is not present in mammalian cells, so the presence of urease in the stomach is evidence that bacteria are present. The presence of urease is not specific for H. pylori , but other bacteria are not usually found in the stomach. The principle of the breath test is shown in Figure 1. Figure 1: Principle of Breath Test To detect H. pylori , urea labeled with 14 C is swallowed by the patient. If gastric urease from H. pylori is present, urea is split to form CO 2 and NH 3 at the interface between the gastric epithelium and lumen and 14 CO 2 is absorbed into the blood and exhaled in the breath. Following ingestion of the capsule by a patient with H. pylori , 14 CO 2 excretion in the breath peaks between 10 and 15 minutes and declines thereafter with a biological half-life of about 15 minutes. 14 C-urea that is not hydrolyzed by H. pylori is excreted in the urine with a half-life of approximately 12 hours. About 10% of the 14 C remains in the body at 72 hours and is gradually excreted with a biological half-life of 40 days. Figure 1: Principle of Breath Test Clinical Studies Two studies were performed. In both studies, patients with gastrointestinal symptoms underwent the breath test and an endoscopy. During the endoscopy, biopsy samples were taken from the antral gastric mucosa for histological analysis (2 samples, Giemsa stain) and rapid urease test (1 sample, CLOtest ). Breath samples were mailed to the TRI-MED lab where they were read in a liquid scintillation counter. Results were reported as disintegrations per minute (DPM). Analysis for accuracy used the ten minute breath sample. A breath sample DPM <50 was defined as a negative result. DPM ≥ 200 was defined as a positive result. DPM in the range of 50–199 was classified as indeterminate. STUDY 1 Of 186 patients who had histopathology and CLOtest (80 men, 106 women), 53 were infected with H. pylori as determined by agreement between histology and CLOtest . The study results are summarized below: Table 1: Study #1 (n = 186, Indeterminate results included) Histology and CLOtest H. pylori Positive Negative Total Notes: PYtest at 10 min. was compared to the gold standard of biopsy results in which histology and CLOtest concurred. Patients who did not have both biopsy tests performed, or in whom the tests differed, were excluded from analysis. There was no statistical difference in test accuracy based on gender of patient. ppv = positive predictive value (true positive divided by total PYtest positive) npv = negative predictive value (true negative divided by total PYtest negative) PYtest Positive 51 8 59 ppv. 86% (DPM Indeterminate 1 8 9 10 min.) Negative 1 117 118 npv. 99% Total 53 133 186 sensitivity specificity 96% 88% STUDY 2 Breath tests were performed on 436 outpatients attending gastroenterology practices at sites in the United States. Seventy-six patients (40 men, 36 women) who had histology and CLOtest were evaluated. The results are summarized below: Table 2: Study #2 (n = 76, Indeterminate results included) Histology and CLOtest H. pylori Positive Negative Total Notes: PYtest at 10 min. was compared to the gold standard of biopsy results in which histology and CLOtest concurred. Patients who did not have both biopsy tests performed, or in whom the tests differed, were excluded from analysis. There was no statistical difference in test accuracy based on gender of patient. ppv = positive predictive value (true positive divided by total PYtest positive) npv = negative predictive value (true negative divided by total PYtest negative) PYtest Positive 22 0 22 ppv. 100% (DPM Indeterminate 4 2 6 10 min.) Negative 1 47 48 npv. 98% Total 27 49 76 sensitivity specificity 82% 96%"],"clinical_pharmacology_table":["<table width=\"80%\"><caption>Table 1: Study #1 (n = 186, Indeterminate results included)</caption><col width=\"15%\" align=\"left\" valign=\"top\"/><col width=\"15%\" align=\"left\" valign=\"top\"/><col width=\"15%\" align=\"center\" valign=\"top\"/><col width=\"15%\" align=\"center\" valign=\"top\"/><col width=\"15%\" align=\"center\" valign=\"top\"/><col width=\"15%\" align=\"center\" valign=\"top\"/><col width=\"10%\" align=\"left\" valign=\"top\"/><thead><tr><th colspan=\"7\" align=\"center\">Histology and CLOtest<footnoteRef IDREF=\"foot1\"/></th></tr><tr><th/><th><content styleCode=\"italics\">H. pylori</content></th><th>Positive</th><th>Negative</th><th>Total</th><th/><th/></tr></thead><tfoot><tr><td colspan=\"7\" align=\"left\"><content styleCode=\"bold\">Notes: </content><content styleCode=\"italics\">PYtest<footnoteRef IDREF=\"foot1\"/> at 10 min. was compared to the gold standard of biopsy results in which histology and CLOtest<footnoteRef IDREF=\"foot1\"/> concurred. Patients who did not have both biopsy tests performed, or in whom the tests differed, were excluded from analysis. There was no statistical difference in test accuracy based on gender of patient.</content></td></tr><tr><td colspan=\"7\" align=\"left\"><content styleCode=\"bold italics\">ppv = positive predictive value (true positive divided by total PYtest<footnoteRef IDREF=\"foot1\"/> positive)</content></td></tr><tr><td colspan=\"7\" align=\"left\" styleCode=\"Botrule\"><content styleCode=\"bold italics\">npv = negative predictive value (true negative divided by total PYtest<footnoteRef IDREF=\"foot1\"/> negative)</content></td></tr></tfoot><tbody><tr><td>PYtest<footnoteRef IDREF=\"foot1\"/></td><td>Positive</td><td styleCode=\"Toprule Lrule\">51</td><td styleCode=\"Toprule Lrule\">8</td><td styleCode=\"Toprule Lrule Rrule\">59</td><td>ppv.</td><td>86%</td></tr><tr><td>(DPM</td><td>Indeterminate</td><td styleCode=\"Toprule Lrule\">1</td><td styleCode=\"Toprule Lrule\">8</td><td styleCode=\"Toprule  Lrule Rrule\">9</td><td/><td/></tr><tr><td>10 min.)</td><td>Negative</td><td styleCode=\"Toprule Lrule\">1</td><td styleCode=\"Toprule Lrule\">117</td><td styleCode=\"Toprule Lrule Rrule\">118</td><td>npv.</td><td>99%</td></tr><tr><td>Total</td><td/><td styleCode=\"Toprule Lrule\">53</td><td styleCode=\"Toprule Lrule\">133</td><td styleCode=\"Toprule Lrule Rrule\">186</td><td/><td/></tr><tr><td/><td/><td styleCode=\"Toprule\">sensitivity</td><td styleCode=\"Toprule\">specificity</td><td styleCode=\"Toprule\"/><td/><td/></tr><tr styleCode=\"Botrule\"><td/><td/><td>96%</td><td>88%</td><td/><td/><td/></tr></tbody></table>","<table width=\"80%\"><caption>Table 2: Study #2 (n = 76, Indeterminate results included)</caption><col width=\"15%\" align=\"left\" valign=\"top\"/><col width=\"15%\" align=\"left\" valign=\"top\"/><col width=\"15%\" align=\"center\" valign=\"top\"/><col width=\"15%\" align=\"center\" valign=\"top\"/><col width=\"15%\" align=\"center\" valign=\"top\"/><col width=\"15%\" align=\"center\" valign=\"top\"/><col width=\"10%\" align=\"center\" valign=\"top\"/><thead><tr><th colspan=\"7\" align=\"center\">Histology and CLOtest<footnoteRef IDREF=\"foot1\"/></th></tr><tr><th/><th><content styleCode=\"italics\">H. pylori</content></th><th>Positive</th><th>Negative</th><th>Total</th><th/><th/></tr></thead><tfoot><tr><td colspan=\"7\" align=\"left\"><content styleCode=\"bold\">Notes: </content><content styleCode=\"italics\">PYtest at 10 min. was compared to the gold standard of biopsy results in which histology and CLOtest concurred. Patients who did not have both biopsy tests performed, or in whom the tests differed, were excluded from analysis. There was no statistical difference in test accuracy based on gender of patient.</content></td></tr><tr><td colspan=\"7\" align=\"left\"><content styleCode=\"bold italics\">ppv = positive predictive value (true positive divided by total PYtest<footnoteRef IDREF=\"foot1\"/> positive)</content></td></tr><tr><td colspan=\"7\" align=\"left\" styleCode=\"Botrule\"><content styleCode=\"bold italics\">npv = negative predictive value (true negative divided by total PYtest<footnoteRef IDREF=\"foot1\"/> negative)</content></td></tr></tfoot><tbody><tr><td>PYtest<footnoteRef IDREF=\"foot1\"/></td><td>Positive</td><td styleCode=\"Toprule Lrule\">22</td><td styleCode=\"Toprule Lrule\">0</td><td styleCode=\"Toprule Lrule Rrule\">22</td><td>ppv.</td><td>100%</td></tr><tr><td>(DPM</td><td>Indeterminate</td><td styleCode=\"Toprule Lrule\">4</td><td styleCode=\"Toprule Lrule\">2</td><td styleCode=\"Toprule  Lrule Rrule\">6</td><td/><td/></tr><tr><td>10 min.)</td><td>Negative</td><td styleCode=\"Toprule Lrule\">1</td><td styleCode=\"Toprule Lrule\">47</td><td styleCode=\"Toprule Lrule Rrule\">48</td><td>npv.</td><td>98%</td></tr><tr><td>Total</td><td/><td styleCode=\"Toprule Lrule\">27</td><td styleCode=\"Toprule Lrule\">49</td><td styleCode=\"Toprule Lrule Rrule\">76</td><td/><td/></tr><tr><td/><td/><td styleCode=\"Toprule\">sensitivity</td><td styleCode=\"Toprule\">specificity</td><td styleCode=\"Toprule\"/><td/><td/></tr><tr styleCode=\"Botrule\"><td/><td/><td>82%</td><td>96%</td><td/><td/><td/></tr></tbody></table>"],"clinical_studies":["Clinical Studies Two studies were performed. In both studies, patients with gastrointestinal symptoms underwent the breath test and an endoscopy. During the endoscopy, biopsy samples were taken from the antral gastric mucosa for histological analysis (2 samples, Giemsa stain) and rapid urease test (1 sample, CLOtest ). Breath samples were mailed to the TRI-MED lab where they were read in a liquid scintillation counter. Results were reported as disintegrations per minute (DPM). Analysis for accuracy used the ten minute breath sample. A breath sample DPM <50 was defined as a negative result. DPM ≥ 200 was defined as a positive result. DPM in the range of 50–199 was classified as indeterminate."],"contraindications":["Contraindications None"],"description":["Description PYtest Registered Trademark or Trademark of Kimberly-Clark Worldwide, Inc. ( 14 C-urea capsules) is intended for use in the detection of gastric urease as an aid in the diagnosis of Helicobacter pylori ( H. pylori ) infection in the human stomach. The test utilizes a liquid scintillation counter for the measurement of 14 CO 2 in breath samples. The capsules are to be used when analysis is planned at the site where the sample is taken. PYtest capsule is a gelatin capsule for oral administration containing 1 µCi of 14 C labeled urea. The urea is adsorbed on sugar spheres and colored yellow with fluorescein. Data on 14 C-urea Structural Formula ( 14 C-urea): NH 2 14 CONH 2 Radiation emission: beta-emission, 49 keV mean , 156 keV max , no other emissions External emission: No external radiation hazard. Low-energy beta emissions only. Maximum range of 0.3 mm in water. Radiological Half-life: 5730 years Maximum effective dose equivalent (EDE) : 0.3 mrem/µCi"],"dosage_and_administration":["Dosage and Administration Materials Needed but not Provided FOR ANALYSIS AT TEST SITE BREATH SAMPLE COLLECTED INTO BALLOON (RECOMMENDED METHOD; SEE FIGURE 2 ) Breath test report form Stopwatch/Timer capable of timing an interval up to 10 minutes Marking pen 1 – 20 ml scintillation vial Breath transfer pump Pipette (10 ml) for measuring fluids Collection fluid (2.5 ml/vial) Scintillation fluid (10 ml/vial) 1 – Mylar collection balloon 1 – Straw 2 – Needles 2 – 30 ml medicine cups Water (40 ml) Any gas pump that is airtight and has a flow rate between .5 and 1 liter per minute may be used. Figure 2: Other Components Figure 2: Other Components FOR ANALYSIS ON SITE BREATH SAMPLE COLLECTED INTO VIAL CAUTION: Kimberly-Clark does not endorse breath sample collection by this method because patients might come into direct contact with the hyamine. Breath test report form Stopwatch/Timer capable of timing an interval up to 10 minutes Safety trap (Figure 3) 1 – Straw 1 – 20 ml scintillation vial Marking pen Pipette (10 ml) for measuring fluids Collection fluid (2.5 ml/vial) Scintillation fluid (10 ml/vial) Figure 3: Typical Safety Trap Figure 3: Typical Safety Trap"],"dosage_forms_and_strengths":["Dosage One PYtest capsule."],"drug_interactions":["Drug Interactions Antibiotics, proton pump inhibitors, sucralfate, and bismuth preparations are known to suppress H. pylori. Ingestion of antibiotics or bismuth within 4 weeks and proton pump inhibitors or sucralfate within 2 weeks prior to performing the test may give false negative results."],"effective_time":"20240916","general_precautions":["General After the patient ingests the 14 C-urea capsule, the sample collected for test purposes is for in vitro diagnostic use only. A false positive test could occur in patients who have achlorhydria. Very rarely, a false positive test may occur due to urease associated with Helicobacters other than H. pylori (i.e. Helicobacter heilmanni ). Limitations of the Test The test has been evaluated in outpatients before elective endoscopy. Test results should be evaluated with clinical signs and patient history when diagnosing H. pylori infection. The performance characteristics of the test have not been established for monitoring the efficacy of antimicrobial therapies for the treatment of H. pylori infection. A negative result does not completely rule out the possibility of H. pylori infection. If clinical signs and patient history suggest H. pylori infection, repeat the PYtest or use an alternative diagnostic method. Radioactivity Persons concerned about very low doses of radioactivity may postpone the test or may decide to use an alternative means of diagnosis. The test produces radiation exposure equal to 24 hours of normal background. In animal experiments, such low doses of radiation do not carry measurable risk. Preclinical studies were not conducted on 14 C-urea. The estimated dose equivalent received from a single administration of PYtest (1 µCi 14 C) is about 0.3 mrem."],"how_supplied":["HOW SUPPLIED PYtest Capsules, clear gelatin capsules each containing 1 μCi of 14C-urea in unit dose packages of 1, 10 and 100. PYtest Kit ( 14 C-urea breath test) is also supplied as a kit containing a PYtest Capsule and breath collection equipment. The PYtest Capsule has a shelf life of two years. The expiration date is printed on the capsule label. PYtest Capsules and Kit should be stored at 15–30 °C (59–86 °F) in an area designated by each individual institution's regulations."],"id":"98311ae8-b8a0-4d38-897b-b74b91817cdb","indications_and_usage":["Indications and Usage PYtest ( 14 C-Urea breath test) is indicated for use in the detection of gastric urease as an aid in the diagnosis of H. pylori infection in the human stomach. The test utilizes a liquid scintillation counter for the measurement of 14 CO 2 in breath samples."],"information_for_patients":["Information for Patients It is necessary for the patient to fast for 6 hours before the test. The patient should also be off antibiotics and bismuth for 1 month, and proton pump inhibitors and sucralfate for 2 weeks prior to the test. Instruct the patient not to handle the capsule directly as this may interfere with the test result. The capsule should be swallowed intact. Do not chew the capsule."],"nursing_mothers":["Nursing Mothers It is not known whether this drug is excreted in human milk. Because many drugs are excreted in human milk, caution should be exercised when PYtest is administered to a nursing woman."],"openfda":{},"overdosage":["Overdosage Risk from radiation is negligible even with a 1000 capsule overdose (0.3 rem). If overdose occurs, the patient may drink one glass of water (150 ml) every hour to hasten excretion of the isotope. Maximum excretion of urea is achieved at a urine output of ≥ 2.0 ml/min."],"package_label_principal_display_panel":["PRINCIPAL DISPLAY PANEL - 10 Capsule Package Label AVANOS* PYtest* 14 C-UREA BREATH TEST CAPSULES FOR THE DETECTION OF HELICOBACTER PYLORI Contents – 10 PYtest* Capsules each containing 1 µCi 14 C-Urea For dosage information, please see package insert 14 C-Urea (5730 years1/2, 156 keV [max.] β-emission) NDC 42536-6044-2 For In Vitro Diagnostic Use Rx Only Store at 15°–30°C (59°–86°F) REF 60442 PRINCIPAL DISPLAY PANEL - 10 Capsule Package Label"],"pediatric_use":["Pediatric Use Clinical studies in children have not been conducted. However, PYtest is expected to work the same in children as in adults. While the dose (1 capsule) does not need to be adjusted, the child must be able to swallow the intact capsule and blow into a straw."],"precautions":["Precautions General After the patient ingests the 14 C-urea capsule, the sample collected for test purposes is for in vitro diagnostic use only. A false positive test could occur in patients who have achlorhydria. Very rarely, a false positive test may occur due to urease associated with Helicobacters other than H. pylori (i.e. Helicobacter heilmanni ). Limitations of the Test The test has been evaluated in outpatients before elective endoscopy. Test results should be evaluated with clinical signs and patient history when diagnosing H. pylori infection. The performance characteristics of the test have not been established for monitoring the efficacy of antimicrobial therapies for the treatment of H. pylori infection. A negative result does not completely rule out the possibility of H. pylori infection. If clinical signs and patient history suggest H. pylori infection, repeat the PYtest or use an alternative diagnostic method. Radioactivity Persons concerned about very low doses of radioactivity may postpone the test or may decide to use an alternative means of diagnosis. The test produces radiation exposure equal to 24 hours of normal background. In animal experiments, such low doses of radiation do not carry measurable risk. Preclinical studies were not conducted on 14 C-urea. The estimated dose equivalent received from a single administration of PYtest (1 µCi 14 C) is about 0.3 mrem. Information for Patients It is necessary for the patient to fast for 6 hours before the test. The patient should also be off antibiotics and bismuth for 1 month, and proton pump inhibitors and sucralfate for 2 weeks prior to the test. Instruct the patient not to handle the capsule directly as this may interfere with the test result. The capsule should be swallowed intact. Do not chew the capsule. Carcinogenesis, mutagenesis, impairment of fertility No studies have been conducted with 14 C-urea to evaluate its potential for carcinogenicity, impairment of fertility, or mutagenicity. Drug Interactions Antibiotics, proton pump inhibitors, sucralfate, and bismuth preparations are known to suppress H. pylori. Ingestion of antibiotics or bismuth within 4 weeks and proton pump inhibitors or sucralfate within 2 weeks prior to performing the test may give false negative results. Pregnancy Pregnancy category C Animal reproduction studies have not been conducted with PYtest ( 14 C-urea). It is also not known whether PYtest can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. PYtest should be given to a pregnant woman only if clearly needed. Nursing Mothers It is not known whether this drug is excreted in human milk. Because many drugs are excreted in human milk, caution should be exercised when PYtest is administered to a nursing woman. Pediatric Use Clinical studies in children have not been conducted. However, PYtest is expected to work the same in children as in adults. While the dose (1 capsule) does not need to be adjusted, the child must be able to swallow the intact capsule and blow into a straw."],"pregnancy":["Pregnancy Pregnancy category C Animal reproduction studies have not been conducted with PYtest ( 14 C-urea). It is also not known whether PYtest can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. PYtest should be given to a pregnant woman only if clearly needed."],"set_id":"13148b04-9295-41bb-bd8b-76dbd4ce7c00","spl_product_data_elements":["PYtest Urea, C-14 Urea C-14 Urea C-14 Light Lemon Yellow Oval"],"spl_unclassified_section":["Procedural Notes Inform the patient to fast for 6 hours prior to the test. The patient should be off antibiotics and bismuth for 1 month, and proton pump inhibitors and sucralfate for 2 weeks prior to the test. Have patient sitting at rest while doing the test. The capsule should not be handled directly as this may interfere with the test result. To avoid contamination by bacteria in the mouth, the capsule should be swallowed intact. Do not chew capsule. Step by Step Procedure for Balloon Breath Sample Collection by Balloon Before the test Label balloon and fill in breath test report form. Check that all materials are present. Minus 1 minute Open the package containing the 14 C-urea capsule and 1 minute tip the capsule into the empty 30 ml cup. Do not handle the capsule directly. Hand the cup to the patient. Fill the second cup with 20 ml lukewarm water. 0 minute Ask the patient to tip the capsule directly into his/her mouth, then swallow it with the 20 ml of lukewarm water. Start the stopwatch when the patient swallows the capsule. Discard waste (e.g., capsule packaging, used straws) according to your facility's regulations. 3 minutes Ask the patient to drink another 20 ml of lukewarm water (in case the capsule may have lodged in the esophagus and not yet reached the gastric mucosa). 10 minutes Push a drinking straw into the neck of the balloon. Ask the patient to hold his/her breath for 5–10 seconds, then blow up a balloon with a slow breath through the straw, filling the balloon completely. Tie the neck of the balloon into a tight knot. Check that the balloon label and the breath test report form are completed correctly. After sample collection See test analysis procedure. Breath Sample Collection by Vial CAUTION: Kimberly-Clark does not endorse the collection of breath samples by this method for patient safety reasons. Before the test Label vial and fill in breath test report form. Vial label should include the patient's name, date of sample collection and time sample is taken. Check that the vial contains 2.5 ml of collection fluid (1.5 ml methanol, 1.0 ml 1 molar hyamine, two drops thymolphthalein pH indicator). Check that all materials are present. Minus 2 minutes Attach a straw to the safety trap (Figure 3). Minus 1 minute Open the package containing the 14C-urea capsule and tip the capsule into the 30 ml cup. Do not handle the capsule directly. Hand the cup to the patient. Fill the second cup with 20 ml lukewarm water. 0 minute Ask the patient to tip the capsule directly into his/her mouth, then swallow it with the 20 ml of lukewarm water. Start the stopwatch when the patient swallows the capsule. Discard waste (e.g., capsule packaging, used straw) according to your facility's regulations. 3 minutes Ask the patient to drink another 20 ml of lukewarm water (in case the capsule may have lodged in the esophagus and not yet reached the gastric mucosa). 10 minutes Ask the patient to hold his/her breath for 5–10 seconds, then blow bubbles into the collection fluid via the safety trap. The patient should blow bubbles until the fluid turns clear. Put lid on vial. After sample collection See test analysis procedure. Test Analysis Procedure General Information The collection fluid contains hyamine, methanol and a pH indicator. Hyamine is a corrosive caustic alkali. If you are using the vial method and collecting breath directly into the collection fluid you must supervise the patient and ensure that a safety trap is used. The amount of hyamine (1 ml of 1/m) and methanol (2.5 ml) in one collection vial is not sufficient to cause serious poisoning. Local irritation to skin or mucous membranes is likely when the solution is blue. After collecting CO 2 the collection fluid turns clear. At this point it is less dangerous because the pH is near neutral. If the collection fluid splashes onto the skin or eyes, wash immediately with water. If the collection fluid is accidentally ingested, wash the mouth with water and have the patient drink 250 ml of water immediately. Consult your poison information center for further facts on hyamine. Scintillation fluid comes in many formulations. It is usually a mixture of toluene and various cyclic hydrocarbons. It is flammable. Biodegradable formulations do exist. Consult your supplier if you have questions. BALLOON READ ON-SITE: Add 2.5 ml collection fluid to each vial. Label the scintillation vial lid to match the label on the balloon. Attach a needle to the inlet and outlet tubes on the pump. Turn on pump. Allow to run for about 15 seconds. Put needle from the rigid outlet tube in a vial until it makes bubbles in the collection fluid. Pierce the label of a filled balloon with the other needle and hold it in a stable position. (Do not pierce the balloon anywhere else or it may tear. Do not squeeze the balloon.) After 2–3 minutes the collection fluid should turn colorless. After the collection fluid is colorless, remove the needles from the balloon and collection fluid and discard according to your facility protocol. Change needles between patients. Turn off pump after last patient sample is transferred. Double check that the label on the vial lid matches the label on the balloon. Add 10 ml scintillation fluid to each vial and mix fluid. Count the sample in liquid scintillation counter for 5 minutes or as directed by the liquid scintillation counter manufacturer. (Note that values of 50–300 DPM can occur immediately after the addition of the scintillation fluid due to chemiluminescence. Chemiluminescence decays rapidly over an hour or two and will reveal itself by falling counts. Read the sample repeatedly until values 10 minutes apart are similar. If DPM is still 50–300, you should allow the sample to settle for 12–24 hours before re-testing.) Include a standard and a blank control vial in each run. VIALS READ ON-SITE See steps 12–14 under \"Balloon read on-site.\"","Quality Control A minimum of 1 mmol of CO 2 is required to perform analysis of a breath sample. The amount of breath required to provide 1 mmol of CO 2 varies depending on the amount of CO 2 the patient is producing. Since a full balloon typically contains at least 1 mmol of CO 2 , the balloon should be completely filled.","Results Interpretation of results (10 minute sample) < 50 DPM Negative for H. pylori 50–199 DPM Indeterminate for H. pylori ≥ 200 DPM Positive for H. pylori The indeterminate result should be evaluated by repeating the PYtest or using an alternative diagnostic method. If repeat breath testing is undertaken, careful history to exclude confounding factors should be obtained. If confounding factors are identified, wait an appropriate time (refer to table 3 ) before repeating the PYtest . The cutoff point of 50 DPM was determined to be the mean +3SD of results obtained in patients who did not have H. pylori . DPM = Disintegrations per minute Table 3: Factors which might cause sub-optimal breath test results Factor Result Comment Recent antibiotic or bismuth (Pepto-Bismol, etc.) false neg. Relapse of partially treated Hp may take 1–4 weeks. Omeprazole (or other proton pump inhibitors) false neg. These agents suppress Hp in 40% of patients. Discontinuefor at least 2 weeks before performing the PYtest . Resective gastric surgery false neg. Isotope may empty rapidly from the stomach. Resective gastric surgery false pos. Patient may be achlorhydric and have bacterial overgrowth (non- Hp urease). Food in stomach (also bezoar, gastroparesis) unknown Isotope may not come into contact with gastric mucosa Patient may be achlorhydric and/or have bacterial overgrowth (non- Hp urease).","Expected Values As shown in Figure 4 approximately 30% of patients tested will be positive for H. pylori . Figure 4: Histogram showing DPM distribution for the PYtest . *Note: DPM groupings were calculated on a logarithmic scale. Empty DPM groupings were not included. Chart includes all patients from Studies 1 and 2. Frequency of DPM group includes samples with DPM < Group Name. DPM = Disintegrations per minute Gold Standard = Agreement between histology and CLOtest If the capsule is damaged or appears abnormal in any way, it may give inaccurate results. Figure 4: Histogram showing DPM distribution for the PYtest*.","Rx Only (USA) U.S. Patent Nos. 4,748,113; 4,830,010","Kimberly-Clark Distributed in the U.S. by Kimberly-Clark Global Sales, LLC, Roswell, GA 30076 USA In USA, please call 1-800-KCHELPS • www.kchealthcare.com Kimberly-Clark, Roswell, GA 30076 USA Kimberly-Clark N.V., Belgicastraat 13, 1930 Zaventem, Belgium Sponsored in Australia by Kimberly-Clark Australia Pty Limited; 52 Alfred Street Milsons Point, NSW 2061 • 1-800-101-021 ©2003 KCWW. All rights reserved. 14-63-133-0-00/70080916"],"spl_unclassified_section_table":["<table width=\"80%\"><caption>Breath Sample Collection by Balloon</caption><col width=\"20%\" align=\"left\" valign=\"top\"/><col width=\"80%\" align=\"left\" valign=\"top\"/><tbody><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">Before the test</td><td styleCode=\"Lrule Rrule\"><list listType=\"ordered\"><item>Label balloon and fill in breath test report form.</item><item>Check that all materials are present.</item></list></td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">Minus  1 minute</td><td styleCode=\"Lrule Rrule\"><list listType=\"ordered\"><item>Open the package containing the <sup>14</sup>C-urea capsule and 1 minute tip the capsule into the empty 30 ml cup. Do not handle the capsule directly.</item><item>Hand the cup to the patient.</item><item>Fill the second cup with 20 ml lukewarm water.</item></list></td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">0 minute</td><td styleCode=\"Lrule Rrule\"><list listType=\"ordered\"><item>Ask the patient to tip the capsule directly into his/her mouth, then swallow it with the 20 ml of lukewarm water.</item><item>Start the stopwatch when the patient swallows the capsule.</item><item>Discard waste (e.g., capsule packaging, used straws) according to your facility&apos;s regulations.</item></list></td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">3 minutes</td><td styleCode=\"Lrule Rrule\">Ask the patient to drink another 20 ml of lukewarm water (in case the capsule may have lodged in the esophagus and not yet reached the gastric mucosa).</td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">10 minutes</td><td styleCode=\"Lrule Rrule\"><list listType=\"ordered\"><item>Push a drinking straw into the neck of the balloon.</item><item>Ask the patient to hold his/her breath for 5&#x2013;10 seconds, then blow up a balloon with a slow breath through the straw, filling the balloon completely.</item><item>Tie the neck of the balloon into a tight knot.</item><item>Check that the balloon label and the breath test report form are completed correctly.</item></list></td></tr><tr><td styleCode=\"Lrule\">After  sample  collection</td><td styleCode=\"Lrule Rrule\">See test analysis procedure.</td></tr></tbody></table>","<table width=\"80%\"><caption>Breath Sample Collection by Vial</caption><col width=\"20%\" align=\"left\" valign=\"top\"/><col width=\"80%\" align=\"left\" valign=\"top\"/><tfoot><tr><td align=\"left\" colspan=\"2\"><content styleCode=\"italics\">CAUTION: Kimberly-Clark does not endorse the collection of breath samples by this method for patient safety reasons.</content></td></tr></tfoot><tbody><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">Before the  test</td><td styleCode=\"Lrule Rrule\"><list listType=\"ordered\"><item>Label vial and fill in breath test report form. Vial label should include the patient&apos;s name, date of sample collection and time sample is taken.</item><item>Check that the vial contains 2.5 ml of collection fluid (1.5 ml methanol, 1.0 ml 1 molar hyamine, two drops thymolphthalein pH indicator).</item><item>Check that all materials are present.</item></list></td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">Minus  2 minutes</td><td styleCode=\"Lrule Rrule\">Attach a straw to the safety trap (Figure 3).</td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">Minus  1 minute</td><td styleCode=\"Lrule Rrule\"><list listType=\"ordered\"><item>Open the package containing the 14C-urea capsule and tip the capsule into the 30 ml cup. Do not handle the capsule directly.</item><item>Hand the cup to the patient.</item><item>Fill the second cup with 20 ml lukewarm water.</item></list></td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">0 minute</td><td styleCode=\"Lrule Rrule\"><list listType=\"ordered\"><item>Ask the patient to tip the capsule directly into his/her mouth, then swallow it with the 20 ml of lukewarm water.</item><item>Start the stopwatch when the patient swallows the capsule.</item><item>Discard waste (e.g., capsule packaging, used straw) according to your facility&apos;s regulations.</item></list></td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">3 minutes</td><td styleCode=\"Lrule Rrule\">Ask the patient to drink another 20 ml of lukewarm water (in case the capsule may have lodged in the esophagus and not yet reached the gastric mucosa).</td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">10 minutes</td><td styleCode=\"Lrule Rrule\">Ask the patient to hold his/her breath for 5&#x2013;10 seconds, then blow bubbles into the collection fluid via the safety trap. The patient should blow bubbles until the fluid turns clear. Put lid on vial.</td></tr><tr><td styleCode=\"Lrule\">After  sample  collection</td><td styleCode=\"Lrule Rrule\">See test analysis procedure.</td></tr></tbody></table>","<table width=\"50%\"><col width=\"50%\" align=\"left\" valign=\"top\"/><col width=\"50%\" align=\"left\" valign=\"top\"/><tbody><tr styleCode=\"Toprule\"><td colspan=\"2\"><content styleCode=\"bold italics\">Interpretation of results (10 minute sample)</content></td></tr><tr><td> &lt; 50 DPM</td><td>Negative for <content styleCode=\"italics\">H. pylori</content></td></tr><tr><td> 50&#x2013;199 DPM</td><td>Indeterminate for <content styleCode=\"italics\">H. pylori</content></td></tr><tr styleCode=\"Botrule\"><td> &#x2265; 200 DPM</td><td>Positive for <content styleCode=\"italics\">H. pylori</content></td></tr></tbody></table>","<table width=\"80%\" ID=\"table3\"><caption>Table 3: Factors which might cause sub-optimal breath test results</caption><col width=\"40%\" align=\"left\" valign=\"top\"/><col width=\"20%\" align=\"left\" valign=\"top\"/><col width=\"40%\" align=\"left\" valign=\"top\"/><thead><tr><th styleCode=\"Lrule\">Factor</th><th styleCode=\"Lrule\">Result</th><th styleCode=\"Lrule Rrule\">Comment</th></tr></thead><tbody><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">Recent antibiotic or bismuth  (Pepto-Bismol, etc.)</td><td styleCode=\"Lrule\">false  neg.</td><td styleCode=\"Lrule Rrule\">Relapse of partially treated <content styleCode=\"italics\">Hp</content> may take 1&#x2013;4 weeks.</td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">Omeprazole (or other proton pump inhibitors)</td><td styleCode=\"Lrule\">false  neg.</td><td styleCode=\"Lrule Rrule\">These agents suppress <content styleCode=\"italics\">Hp</content> in 40% of patients. Discontinuefor at least 2 weeks before performing the PYtest<footnoteRef IDREF=\"foot1\"/>.</td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">Resective gastric surgery</td><td styleCode=\"Lrule\">false  neg.</td><td styleCode=\"Lrule Rrule\">Isotope may empty rapidly from the stomach.</td></tr><tr styleCode=\"Botrule\"><td styleCode=\"Lrule\">Resective gastric surgery</td><td styleCode=\"Lrule\">false  pos.</td><td styleCode=\"Lrule Rrule\">Patient may be achlorhydric and have bacterial overgrowth (non-<content styleCode=\"italics\">Hp</content> urease).</td></tr><tr><td styleCode=\"Lrule\">Food in stomach (also bezoar, gastroparesis)</td><td styleCode=\"Lrule\">unknown</td><td styleCode=\"Lrule Rrule\">Isotope may not come into contact with gastric mucosa Patient may be achlorhydric and/or have bacterial overgrowth (non-<content styleCode=\"italics\">Hp</content> urease).</td></tr></tbody></table>","<table width=\"90%\"><col width=\"20%\" align=\"left\" valign=\"top\"/><col width=\"80%\" align=\"left\" valign=\"top\"/><tbody><tr styleCode=\"Toprule\"><td><content styleCode=\"bold italics\">Kimberly-Clark</content></td><td>Distributed in the U.S. by Kimberly-Clark Global Sales, LLC, Roswell, GA 30076 USA  <content styleCode=\"bold\">In USA, please call 1-800-KCHELPS &#x2022; www.kchealthcare.com </content> Kimberly-Clark, Roswell, GA 30076 USA  Kimberly-Clark N.V., Belgicastraat 13, 1930 Zaventem, Belgium  Sponsored in Australia by Kimberly-Clark Australia Pty Limited; 52 Alfred Street  Milsons Point, NSW 2061 &#x2022; 1-800-101-021</td></tr><tr styleCode=\"Botrule\"><td colspan=\"2\">&#xA9;2003 KCWW. All rights reserved.  14-63-133-0-00/70080916</td></tr></tbody></table>"],"storage_and_handling":["The PYtest Capsule has a shelf life of two years. The expiration date is printed on the capsule label. PYtest Capsules and Kit should be stored at 15–30 °C (59–86 °F) in an area designated by each individual institution's regulations."],"teratogenic_effects":["Pregnancy category C Animal reproduction studies have not been conducted with PYtest ( 14 C-urea). It is also not known whether PYtest can cause fetal harm when administered to a pregnant woman or can affect reproduction capacity. PYtest should be given to a pregnant woman only if clearly needed."],"version":"8","warnings":["Warnings None"]}