JACKSON BIOPSY FORCEPS

Primary DI
00192896049574
Brand
JACKSON BIOPSY FORCEPS
Company
SONTEC INSTRUMENTS, INC.
Model
1100-718C
Catalog number
1100-718C
Device description
JACKSON BIOPSY FORCEPS STRAIGHT ROUND CUP
Published
2018-09-11
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
false
Single use
false

Related Records

Contact Domains

Product Codes

CodeName
FCLFORCEPS, BIOPSY, NON-ELECTRIC

Product Code Classifications

CodeDeviceSpecialtyClass
FCLForceps, Biopsy, Non-ElectricGastroenterology, Urology1

Identifiers And Packaging

IdentifierTypeAgencyPackage quantityStatus
00192896049574PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifierGTIN-14 normalizedUPC-AEAN-13
00192896049574001928960495741928960495740192896049574

GMDN Terms

TermDefinition
Rigid endoscopic biopsy forceps, reusableA rigid, manual, non-electrosurgical instrument intended to obtain tissue specimens during endoscopic procedures (e.g., laparoscopy, thoracoscopy, spinoscopy, arthroscopy). It is typically constructed as a long instrument with one sliding and one stationary rod whose distal ends are equipped with scissors-like cups with cutting edge rims, which are operated by a control handle at the proximal end of the instrument. It is introduced into the body through an artificial orifice of the body or the working channel of the endoscope. This is a reusable device.

Device Sizes

TypeValueUnit
Device Size Text, specify0
Length11.75Inch

Sterilization Methods

Method
Moist Heat or Steam Sterilization;Dry Heat Sterilization

Contacts

PhoneEmail
+1(800) 821-7496info@sontecinstruments.com
+1(800)821-7496info@sontecinstruments.com

Regulatory Flags

DUNS number
040729840
Device count
1
DM exempt
false
Premarket exempt
true
HCT/P
false
Kit
false
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
false
Expiration date on label
false
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
false
Sterilization required before use
true

Other Devices From This Company

Primary DIBrandModelCatalogPublished
00192896105171Small Plates355-236A355-236A2020-10-05
00192896122833Intraocular Set1100-034-SET1100-034-SET2026-03-19
00192896122840Alyea-Babcock Vasectomy Clamp516-695516-6952026-03-19
00192896122857Diamond Head Grasping Forceps1273-1251273-1252026-03-19
00192896122864Velociraptor Junior Rongeur1273-171F1273-171F2026-03-19
00192896122871Spoon Curette2900-2222900-2222026-03-19
00192896122888Dissector2900-2332900-2332026-03-19
00192896122895Ball Dissector2900-2352900-2352026-03-19
00192896122901Hook Dissector2900-2372900-2372026-03-19
00192896122918Hook Dissector2900-2382900-2382026-03-19
00192896122925Spatula Dissector2900-2422900-2422026-03-19
00192896122932Spatula Dissector2900-2442900-2442026-03-19
00192896122949Deluxe Alligator Grasping Forceps1100-333D1100-333D2026-03-19
00192896122680Schroeder Vulsellum Bone Clamp1103-0641103-0642026-03-10
00192896122697Cooley Vascular Clamp2100-527C2100-527C2026-03-10
00192896122703Ochsner Dissector2700-155T2700-155T2026-03-10
00192896122710Debakey Coarctation Clamp2100-6312100-6312026-03-10
00192896122727Debakey Coarctation Clamp2100-6352100-6352026-03-10
00192896122734Metzenbaum Scissors1200-5211200-5212026-03-10
00192896122741Micro Alligator Forceps469-017469-0172026-03-10

Other Devices Sharing Product Codes

Primary DIBrandCompanyProduct codePublished
00190776418021MillenniumAvalign Technologies, Inc.FCL2026-03-23
06970671381569AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2026-03-23
G3731433010Zinnanti SurgicalZinnanti Surgical Design Group IncFCL2026-03-04
00190776415617MillenniumAvalign Technologies, Inc.FCL2026-01-28
18051887049841THD BIOPSYTHD SPAFCL2026-01-07
18051887049865THD BIOPSYTHD SPAFCL2026-01-07
18051887049889THD BIOPSYTHD SPAFCL2026-01-07
06970671381026AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970671381040AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970671381187AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970671381200AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970671381248AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970671381323AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970671381347AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970671381477AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970671381491AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970671381545AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970800684059AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-12-29
06970671381361AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-08-08
06970671381385AltonAlton (Shanghai) Medical Instruments Co., Ltd.FCL2025-08-08
00194613029449MSI Precision Specialty InstrumentsMed Saver, Inc.FCL2025-08-01
00194613029456MSI Precision Specialty InstrumentsMed Saver, Inc.FCL2025-08-01
00194613029463MSI Precision Specialty InstrumentsMed Saver, Inc.FCL2025-08-01
00194613029470MSI Precision Specialty InstrumentsMed Saver, Inc.FCL2025-08-01
00194613034511MSI Precision Specialty InstrumentsMed Saver, Inc.FCL2025-08-01
00194613074371MSI Precision Specialty InstrumentsMed Saver, Inc.FCL2025-08-01
00194613077471MSI Precision Specialty InstrumentsMed Saver, Inc.FCL2025-08-01
00194613077938MSI Precision Specialty InstrumentsMed Saver, Inc.FCL2025-08-01
00194613082642MSI Precision Specialty InstrumentsMed Saver, Inc.FCL2025-08-01
00194613082796MSI Precision Specialty InstrumentsMed Saver, Inc.FCL2025-08-01