Intramedullary Reamer

Primary DI
00810094691486
Brand
Intramedullary Reamer
Company
TOTAL JOINT ORTHOPEDICS, INC.
Model
2014.11.000
Device description
Intramedullary Reamer, Size 11
Published
2023-05-24
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
HTOREAMER

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HTOReamerOrthopedic1

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00810094691486PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00810094691486008100946914868100946914860810094691486

GMDN Terms#

Term, Definition table
TermDefinition
Medullary canal orthopaedic reamer, rigidAn orthopaedic surgical instrument designed to open and enlarge the medullary canal (e.g., in the femur, tibia, ulnar) for the insertion of various devices during prosthesis implantation or fracture fixation procedures. It is typically designed as a long, cylindrical, rigid shaft with straight, spiralled, or contoured flutes that function as cutting surfaces; it may include a transverse milling (spotfacing) burr to level the end of the bone (e.g., post amputation). It is typically made of a high-grade stainless steel and is available in various sizes. It is intended for manual or powered rotation. This is a reusable device intended to be sterilized prior to use.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Device Size Text, specify0

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00The Klassic Knee System should be stored in a clean, dry location at room temperature
Special Storage Condition, Specify00The Klassic Knee System should be stored in a clean, dry location at room temperature

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(801)486-6070udi@tjoinc.com

Regulatory Flags#

DUNS number
078416717
Device count
1
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00810094692940AP Sizer with Short LegsSRI-100502026-05-15
00810094692728CR Femoral Trial, Grit BlastedSRI-10051.012026-02-05
00810094692735CR Femoral Trial, Grit BlastedSRI-10051.022026-02-05
00810094692742CR Femoral Trial, Grit BlastedSRI-10051.032026-02-05
00810094692759CR Femoral Trial, Grit BlastedSRI-10051.042026-02-05
00810094692766CR Femoral Trial, Grit BlastedSRI-10051.052026-02-05
00810094692773CR Femoral Trial, Grit BlastedSRI-10051.062026-02-05
00810094692780CR Femoral Trial, Grit BlastedSRI-10051.072026-02-05
00810094692506Tibial Broach Impactor, Revision2904.00.0002025-05-14
00810094692278Universal Cone Impactor Head2021.12.0122025-04-24
00810094692285Universal Cone Impactor Head2021.34.0182025-04-24
00810094692292Universal Cone Impactor Head2021.57.0242025-04-24
00810094691950Universal Cone Impactor Head, Size 1, 12°2021.01.0122024-09-06
00810094691967Universa Cone Impactor Head, Size 2, 12°2021.02.0122024-09-06
00810094691974Universal Cone Impactor Head, Size 3, 18°2021.03.0182024-09-06
00810094691981Universal Cone Impactor Head, Size 4, 18°2021.04.0182024-09-06
00810094691998Universal Cone Impactor Head, Size 5, 24°2021.05.0242024-09-06
00810094692001Universal Cone Impactor Head, Size 6, 24°2021.06.0242024-09-06
00810094692018Universal Cone Impactor Head, Size 7, 24°2021.07.0242024-09-06
00819251021197Femoral Stem Impactor with Anteversion 1307.00.0002023-12-11

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
08800017270265BENCOXCorentec Co., LtdHTO2026-04-02
08800017270272BENCOXCorentec Co., LtdHTO2026-04-02
08800017270289BENCOXCorentec Co., LtdHTO2026-04-02
08800017270296BENCOXCorentec Co., LtdHTO2026-04-02
08800017270302BENCOXCorentec Co., LtdHTO2026-04-02
08800017270319BENCOXCorentec Co., LtdHTO2026-04-02
08800017270326BENCOXCorentec Co., LtdHTO2026-04-02
08800017270333BENCOXCorentec Co., LtdHTO2026-04-02
08800017270340BENCOXCorentec Co., LtdHTO2026-04-02
08800017270364BENCOXCorentec Co., LtdHTO2026-04-02
08800017270388BENCOXCorentec Co., LtdHTO2026-04-02
08800017270401BENCOXCorentec Co., LtdHTO2026-04-02
08800017270425BENCOXCorentec Co., LtdHTO2026-04-02
08800017270449BENCOXCorentec Co., LtdHTO2026-04-02
08800017270463BENCOXCorentec Co., LtdHTO2026-04-02
08800017270470BENCOXCorentec Co., LtdHTO2026-04-02
08800017270487BENCOXCorentec Co., LtdHTO2026-04-02
08800017270500BENCOXCorentec Co., LtdHTO2026-04-02
08800017270524BENCOXCorentec Co., LtdHTO2026-04-02
08800017270548BENCOXCorentec Co., LtdHTO2026-04-02
08800017270562BENCOXCorentec Co., LtdHTO2026-04-02
08800017270579BENCOXCorentec Co., LtdHTO2026-04-02
08800017270586BENCOXCorentec Co., LtdHTO2026-04-02
08800017270593BENCOXCorentec Co., LtdHTO2026-04-02
08800017270609BENCOXCorentec Co., LtdHTO2026-04-02
08800017270616BENCOXCorentec Co., LtdHTO2026-04-02
08800017270623BENCOXCorentec Co., LtdHTO2026-04-02
07640187918410TRIGEN MAX ENTRY REAMER 12.5 MM, HALL-JACOBSMPS Micro Precision Systems AGHTO2026-02-24
G079C5090000070Golden Isles Pedicle Screw SystemIntelivation, LLCHTO2022-09-23
07640187910407LINK InstrumentWALDEMAR LINK GmbH & Co. KGHTO2019-08-05