NA

Primary DI
04037691146089
Brand
NA
Company
Maquet Cardiopulmonary AG
Model
Ven.Cath.,reinf.,Pilot tip,90° bent
Catalog number
70100.4596
Device description
Venous Catheter, wire reinforced, Pilot tip, 90° bent
Published
2015-10-24
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DWFCATHETER, CANNULA AND TUBING, VASCULAR, CARDIOPULMONARY BYPASS

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DWFCatheter, Cannula And Tubing, Vascular, Cardiopulmonary BypassCardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K020784000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K020784000JOSTRA SINGLE STAGE VENOUS RETURN CATHETERSJostra AG2003-01-09DWF

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04037691146089PackageGS110Not in Commercial Distribution
04037691235066PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04037691146089040376911460894037691146089
04037691235066040376912350664037691235066

GMDN Terms#

Term, Definition table
TermDefinition
Cardiopulmonary bypass cannula, venousA sterile, semi-rigid or rigid tube intended to be used during open heart surgery where it is surgically inserted, typically into the right atrium and superior/inferior vena cava, to serve as a channel for the transport of blood to a cardiopulmonary bypass system (heart-lung machine) tubing circuit where the blood is pumped and oxygenated. It is typically a moulded plastic tube with stainless steel wire reinforcement, to prevent kinking/collapse, and having multiple perforations at the distal end and possibly a non-reinforced clamping site at the proximal end. It is typically inserted using a compatible trocar. This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Catheter Gauge20French
Device Size Text, specify0
Device Size Text, specify0
Length33Centimeter

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+49072229320info.cp@maquet.com

Regulatory Flags#

DUNS number
316153865
Device count
1
DM exempt
false
Premarket exempt
false
HCT/P
false
Kit
false
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
true
Expiration date on label
true
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
false
Sterilization required before use
false

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04037691650326ROTAFLOWCentrifugal Pump, SOFTLINE70104.75532015-10-30
04037691645148NACARDIOHELP Emergency Drive holder, Rail70104.93042016-02-29
04037691645155NACARDIOHELP Emergency Drive Holder, Mast70104.80062016-02-29
04037691720791NACARDIOHELP Holder for mast HKH 9102-M70104.95842016-02-29
04037691456584NAWall holder HKH 882070104.53662016-02-29
04037691717968NACardiohelp Mobile Holder HKH 886070105.08972016-02-29
04037691718330NAGas bottle holder f. helicopter HKH 888070105.09012016-02-29
04058863084336CardiohelpMobile Holder HKH 886070107.3079 2018-03-01
04037691075051VBT Venous Bubble TrapBEQ-VBT 160, BIOLINE, Sterile70103.08842017-03-13
04037691209722NAVBT Venous Bubble Trap70102.98052015-10-24
04037691349251BMU 40"BMU 40 Cell 1/2"""70104.08042016-01-18
04037691349268BMU 40"BMU 40 Cell 3/8"""70104.08442016-01-18
04037691349275BMU 40"BMU 40 Cell 1/4"""70104.08452016-01-18
04037691349282BMU 40"BMU 40 Sensor 3/8"""70104.08492016-01-18
04037691349299BMU 40"BMU 40 Sensor 1/4"""70104.08502016-01-18
04037691349305BMU 40"BMU 40 Sensor 3/16"""70104.08512016-01-18
04037691670164QUADROX-iPediatric, diffusion, BIOLINE70105.03302015-10-24
04037691770970QUADROX-iPediatric, filter70105.52152015-10-24
04058863017341QUADROX-iHMO 71000-USA #SQUADROX-i Adult + Coating, Filter70106.78232017-02-16
04058863017372QUADROX-iBEQ-HMO 71000-USA #SQUADROX-i Adult+BIOLINE +Filte70106.78292017-02-16

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
18051160302878Quantum SuperPAC Tubing Set - SP05E-BBSPECTRUM MEDICAL SRLDWF2026-05-27
08033178019620Aortic Root cannulaSORIN GROUP ITALIA SRLDWF2026-03-06
08033178019637Aortic Root cannulaSORIN GROUP ITALIA SRLDWF2026-03-06
08033178019644Vessel CannulaSORIN GROUP ITALIA SRLDWF2026-03-06
08033178019651Vessel CannulaSORIN GROUP ITALIA SRLDWF2026-03-06
08033178019668Vessel CannulaSORIN GROUP ITALIA SRLDWF2026-03-06
08033178019675Vessel CannulaSORIN GROUP ITALIA SRLDWF2026-03-06
08033178017190Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017206Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017213Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017220Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017237Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017244Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017251Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017268Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017275Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178017312Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178018074Coronary Sinus CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178018098Coronary Sinus CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178018104Coronary Sinus CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178019026Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178019033Cardioplegia CannulaSORIN GROUP ITALIA SRLDWF2026-02-11
08033178019040Ventricular Vent CatheterSORIN GROUP ITALIA SRLDWF2026-02-11
08033178019057Ventricular Vent CatheterSORIN GROUP ITALIA SRLDWF2026-02-11
08033178019064Ventricular Vent CatheterSORIN GROUP ITALIA SRLDWF2026-02-11
08033178019071Ventricular Vent CatheterSORIN GROUP ITALIA SRLDWF2026-02-11
08033178019088Ventricular Vent CatheterSORIN GROUP ITALIA SRLDWF2026-02-11
08033178019095Ventricular Vent CatheterSORIN GROUP ITALIA SRLDWF2026-02-11
08033178019101Ventricular Vent CatheterSORIN GROUP ITALIA SRLDWF2026-02-11
08033178019118Ventricular Vent CatheterSORIN GROUP ITALIA SRLDWF2026-02-11