NA

Primary DI
04546540350855
Brand
NA
Company
Stryker Leibinger GmbH & Co. KG
Model
6001-088-427
Catalog number
6001-088-427
Device description
SUCTION TUBE, 2.7MM LH FRONTAL SINUS
Published
2016-08-24
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
HAWNeurological stereotaxic Instrument

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HAWNeurological Stereotaxic InstrumentNeurology2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04546540350855PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04546540350855045465403508554546540350855

GMDN Terms#

Term, Definition table
TermDefinition
Stereotactic surgery system probe, reusableA long, slender, rod-like device made of metal, used during image guided surgery (e.g., neurosurgical or orthopaedic surgery procedures) to accurately position implantable devices (e.g., shunts), or to correlate the position of its tip to that of a targeted tissue of interest within a patient so that this area of tissue is clearly pinpointed with respect to diagnostic images stored in the stereotactic surgery system. This is a reusable device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Device Size Text, specify0

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity25 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius30 Degrees Celsius
Special Storage Condition, Specify003 V
Storage Environment Atmospheric Pressure50 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius40 Degrees Celsius

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Regulatory Flags#

DUNS number
316153956
Device count
1
Lot or batch
true
Serial number
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
37613327122962NA29-9300329-930032018-04-13
04546540274250NA64-0013264-001322017-01-11
07613327122893NA29-9300129-930012017-12-01
07613327122909NA29-9200129-920012017-03-31
07613327122916NA29-9200329-920032017-03-31
07613327122930NA29-9200229-920022017-03-31
07613327122947NA29-9100229-910022017-03-31
07613327122978NA29-9300229-930022017-12-01
07613327123326NA29-9200429-920042017-03-31
37613154881872PINABALL6003-003-0906003-003-0902016-09-21
57613252088436TLS, Quintube663066302016-08-24
07613327465532NA92-0023292-002322019-05-03
07613327465549NA92-0023092-002302019-05-03
04546540134790NA01-0323001-032302017-01-11
04546540134974NA01-0401001-040102016-12-08
04546540134998NA01-0407001-040702016-12-08
04546540135018NA01-0410001-041002016-12-08
04546540138477NA01-0956101-095612016-12-08
04546540141514NA01-1531501-153152017-01-11
04546540143242NA01-1971501-197152016-12-08

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00650551006701PMT CORPORATION - STEREOTACTICPMT CORPORATIONHAW2026-06-09
00650551006718PMT CORPORATION - STEREOTACTICPMT CORPORATIONHAW2026-06-09
00650551006725PMT CORPORATION - STEREOTACTICPMT CORPORATIONHAW2026-06-09
00650551006732PMT CORPORATION - STEREOTACTICPMT CORPORATIONHAW2026-06-09
00763000811129MedtronicMEDTRONIC NAVIGATION, INC.HAW2026-06-07
00860012056828Zeta Navigation SystemZeta Surgical Inc.HAW2026-06-02
08720892330826Ball Joint Guide Array (BJGA)-Navigation SetBayer Medical Care B.V.HAW2026-04-24
08720892330833Ball Joint Guide Array (BJGA)-Guide SetBayer Medical Care B.V.HAW2026-04-24
07340201501887Leksell Vantage Stereotactic SystemElekta Solutions ABHAW2025-03-31
10381780542278CRW®INTEGRA LIFESCIENCES CORPORATIONHAW2024-06-28
10381780542285CRW®INTEGRA LIFESCIENCES CORPORATIONHAW2024-06-28
10381780542292Integra®INTEGRA LIFESCIENCES CORPORATIONHAW2024-06-03
G076A012354A1Localite TMS Navigator TSLOCALITE GmbHHAW2023-07-05
G076A012355A1Localite TMS Navigator TSLOCALITE GmbHHAW2023-07-05
07613327499711N/AStryker Leibinger GmbH & Co. KGHAW2023-03-23
07613327500516N/AStryker Leibinger GmbH & Co. KGHAW2022-07-22
07613327500561N/AStryker Leibinger GmbH & Co. KGHAW2022-07-22
07613327500578N/AStryker Leibinger GmbH & Co. KGHAW2022-07-22
07613327503265N/AStryker Leibinger GmbH & Co. KGHAW2022-07-22
10603295522850VELYSDEPUY (IRELAND)HAW2021-07-30
07613327413076n/aStryker Leibinger GmbH & Co. KGHAW2018-08-08
07613327413090n/aStryker Leibinger GmbH & Co. KGHAW2018-08-08
07613327413205n/aStryker Leibinger GmbH & Co. KGHAW2018-08-08
10603295493624SIGMADEPUY ORTHOPAEDICS, INC.HAW2018-04-19
10650551098277PMT CORPORATION - STEREOTACTICPMT CORPORATIONHAW2018-01-28
10381780167334CRW®INTEGRA LIFESCIENCES CORPORATIONHAW2017-04-14
10381780252252CRW®INTEGRA LIFESCIENCES CORPORATIONHAW2017-04-14
10381780252351Integra®INTEGRA LIFESCIENCES CORPORATIONHAW2017-04-14
10381780252368Integra®INTEGRA LIFESCIENCES CORPORATIONHAW2017-04-14
10381780252375CRW®INTEGRA LIFESCIENCES CORPORATIONHAW2017-04-14