HITACHI

Primary DI
04562122955850
Brand
HITACHI
Company
HITACHI, LTD.
Model
UST-995-7.5
Device description
Probe
Published
2016-09-13
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
ITXTransducer, Ultrasonic, Diagnostic
IYNSystem, Imaging, Pulsed Doppler, Ultrasonic
IYOSystem, Imaging, Pulsed Echo, Ultrasonic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
ITXTransducer, Ultrasonic, DiagnosticRadiology2
IYNSystem, Imaging, Pulsed Doppler, UltrasonicRadiology2
IYOSystem, Imaging, Pulsed Echo, UltrasonicRadiology2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04562122955850PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04562122955850045621229558504562122955850

GMDN Terms#

Term, Definition table
TermDefinition
Surgical ultrasound imaging transducerA hand-held ultrasound imaging transducer assembly designed to be positioned within a surgical site for localized intraoperative imaging applications. It is sometimes referred to as a surgical probe or fingertip probe. It steers, focuses, and detects the ultrasound beam and resulting echoes either mechanically or electronically. This group of devices includes ultrasound imaging transducer assemblies used with A-mode, B-mode, M-mode, Doppler, colour Doppler (CD), and duplex (combination imaging, Doppler and/or colour flow) scanning capabilities. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-10 Degrees Celsius50 Degrees Celsius

Sterilization Methods#

Method table
Method
"[""Liquid Chemical"", ""Peracetic Acid"", ""Hydrogen Peroxide"", ""Ethylene Oxide""]"
Liquid Chemical;Peracetic Acid;Hydrogen Peroxide;Ethylene Oxide

Regulatory Flags#

DUNS number
693002605
Device count
1
Serial number
true
Manufacturing date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04560333350280PROBEATSmall Field Applicator for PROBEAT-V2026-01-20
04560333350204PROBEATPROBEAT-FR2024-01-19
04560333350211PROBEATMini Ridge Filter and auxiliary functions for PROB2023-12-20
04560333350228PROBEATReal Time Image Gating System for Proton Beam Ther2023-12-20
04562122958639HITACHIDAS-RS12019-07-01
04560333350198PROBEATSmall Field Applicator for PROBEAT-V2023-10-02
04560333350006PROBEATPROBEAT-CR2019-09-24
04562122951555HITACHIMP-2445-SET2018-09-24
04562122951562HITACHIMP-24502018-09-23
04562122951616HITACHIMP-2748-SET2018-09-24
04562122951630HITACHIMP-2445-G142018-09-24
04562122951647HITACHIMP-2445-G162018-09-24
04562122951654HITACHIMP-2445-G172018-09-24
04562122951661HITACHIMP-2445-G182018-09-24
04562122951678HITACHIMP-2445-G222018-09-24
04562122951685HITACHIMP-2452-G162018-09-24
04562122951692HITACHIMP-2452-G182018-09-24
04562122951708HITACHIMP-2748-G162018-09-24
04562122951715HITACHIMP-2748-G172018-09-24
04562122951722HITACHIMP-2748-G182018-09-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
08033737713037THD Procto Software SystemTHD SPAITX2021-07-19
08052461860046Echolight S.p.a.ECHOLIGHT SPAIYO2021-03-05
08056304454263MyLabSigma eliteESAOTE SPAIYO2020-10-23
08056304453891E 3-12ESAOTE SPAITX2019-12-20
08056304454096C 2-9ESAOTE SPAITX2019-12-20
08056304453419MyLabX8ESAOTE SPAIYN2019-12-20
08056304453419MyLabX8ESAOTE SPAIYO2019-12-20
08056304454126MyLabX8 eXPESAOTE SPAIYO2019-12-20
08056304454126MyLabX8 eXPESAOTE SPAIYN2019-12-20
08056304453518MyLabX6ESAOTE SPAIYN2019-06-13
08056304453518MyLabX6ESAOTE SPAITX2019-06-13
08056304453525MyLabX7ESAOTE SPAITX2019-06-13
08056304453525MyLabX7ESAOTE SPAIYO2019-06-13
08056304453563MyLabX5ESAOTE SPAITX2019-06-13
08056304453563MyLabX5ESAOTE SPAIYO2019-06-13
08056304453617MyLabOmegaESAOTE SPAIYO2019-06-13
08056304453617MyLabOmegaESAOTE SPAIYN2019-06-13
08056304453679MyLabSigmaESAOTE SPAIYN2019-06-13
08056304453679MyLabSigmaESAOTE SPAIYO2019-06-13
08056304453921MyLab 9ESAOTE SPAITX2019-06-13
08056304453921MyLab 9ESAOTE SPAIYN2019-06-13
08056304452658MyLab 9 eXPESAOTE SPAITX2018-02-19
08056304452658MyLab 9 eXPESAOTE SPAIYN2018-02-19
08056304452603MyLabEight eXPESAOTE SPAIYO2017-04-03
08056304452603MyLabEight eXPESAOTE SPAIYN2017-04-03
08056304452610MyLabEightESAOTE SPAITX2017-04-03
08056304452610MyLabEightESAOTE SPAIYO2017-04-03
08056304452597MyLabSeven ESAOTE SPAITX2017-02-24
08056304452597MyLabSeven ESAOTE SPAIYO2017-02-24
08056304453013MyLabOneEsaote Europe B.V.IYO2017-02-24