Edge

Primary DI
10884524002194
Brand
Edge
Company
Covidien LP
Model
E2250HNSB
Device description
Pencil,Blade Electrode, Holster
Published
2016-09-24
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10884524002194PrimaryGS10
20884524002191Unit of UseGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
1088452400219410884524002194
2088452400219120884524002191

GMDN Terms#

Term, Definition table
TermDefinition
Open-surgery electrosurgical handpiece/electrode, monopolar, single-useA rigid device consisting of combined electrosurgical handpiece and monopolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation during an open surgical procedure. It is available in a variety of forms (e.g., pen, pistol-shaped forceps, pincer-shaped forceps, scissors) and may also include irrigation, aspiration, lavage and/or surgical plume (smoke) evacuation features to support its primary electrosurgical function. This is a single-use device intended to be used in a sterile condition.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length10Feet

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity0 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature-29 Degrees Fahrenheit149 Degrees Fahrenheit

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(508)261-8000covidien.udi@covidien.com

Regulatory Flags#

DUNS number
058614483
Device count
50
Lot or batch
true
Manufacturing date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10884521072602V-LocVLOCN204L2015-09-02
20884521126852Sofsilk1700022016-09-24
10884521091986NellcorSC-A-I2026-05-25
10884521758803Vascufil8886470311V-22020-07-19
10884521816312McGRATH MAC350-005-0002021-10-21
10884521816329McGRATH MAC350-013-0002021-08-30
10884521816336McGRATH MAC350-017-0002021-10-18
10884521816343McGRATH MAC350-072-0002022-06-13
10884521824317McGRATH MAC350-005-0002022-09-25
10884521824324McGRATH MAC350-013-0002021-10-30
10884521824331McGRATH MAC350-017-0002021-08-26
10884521824348McGRATH MAC350-072-0002023-06-19
10884521850118McGRATH MAC350-005-0002025-04-27
10884521850125McGRATH MAC350-013-0002025-04-27
10884521850132McGRATH MAC350-017-0002025-04-27
10884521850149McGRATH MAC350-072-0002025-04-27
15060272980310McGRATH MAC350-005-0002021-08-02
15060272980327McGRATH MAC350-013-0002022-01-17
15060272980334McGRATH MAC350-072-0002021-04-18
15060272980341McGRATH MAC350-017-0002021-03-27

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
07613327693287MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693294MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693362MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693379MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693386MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693393MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693409MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693416MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693423MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693430MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693447MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693454MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693461MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693478MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693485MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693492MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693508MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693515MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693522MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693539MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693546MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693553MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693560MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693577MalisSTRYKER CORPORATIONGEI2026-02-25
08886479300306RhinAer+ StylusAerin Medical Inc.GEI2025-09-19
07613327556469NeptuneSTRYKER CORPORATIONGEI2025-01-30
07613327548204Neptune SafeAirSTRYKER CORPORATIONGEI2025-01-06
07613327556650NeptuneSTRYKER CORPORATIONGEI2024-12-13
07613327548129NeptuneSTRYKER CORPORATIONGEI2024-12-10
07613327548143NeptuneSTRYKER CORPORATIONGEI2024-12-10