TRAILBLAZER TRANSPORT INCUBATOR TI 100 NA

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 1998-04-21 for TRAILBLAZER TRANSPORT INCUBATOR TI 100 NA manufactured by Hill-rom Air-shields.

Event Text Entries

[132791] Problem: fire hazard when operated from the vehicle 12v supply. Action: when connecting an external dc supply to the incubator ensure that: the positive and negative leads are clearly distinguishable, any mains cables connected to the incubator or equipment connected to it are removed, the negative lead connection is made first, and the negative lead connection is secure. When disconnecting the incubator from the external dc supply ensure that the positive connector is removed first. Ensure that these instructions are included in all local protocols for the transport of neonates and ensure that staff are aware that failure to follow this instruction could at worst result in fire and at least in serious injury from smoke inhalation. Consideration should be given to early replacements of these units. Background: when the incubator is used in an ambulance an electrical return path may be created between the incubator and the vehicle. Connection of the 12v supply terminal may result in a fire hazard. 1. The wiring in a trailblazer incubator melted and produced smoke when the positive terminal was connected to the ambulance supply. 2. The trailblazer incubator does not comply with iec 601-1 in that its external negative supply is connected to its chassis. 3. If the external positive supply is connected but the external negative supply has not been connected, current can flow through the anchor points of the incubator or any trailing mains leads earth pins to the ambulance chassis. Because this path is not intended to carry a high current damage to the negative wiring in the incubator may occur. 4. Connecting the negative supply first will ensure an adequate return path for the current. 5. In this instance the 12v leads were not clearly color coded in that the color flashes were easily obscured by the operator's hand. 6. Additionally, users should be aware that connecting the negative supply lead to the vehicle positive supply will result in high current flow and the probability of fire.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report NumberMW4002194
MDR Report Key163389
Date Received1998-04-21
Date of Report1998-03-01
Date Added to Maude1998-04-22
Event Key0
Report Source CodeVoluntary report
Manufacturer LinkN
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag0
Health Professional3
Initial Report to FDA0
Report to FDA0
Event Location3
Single Use0
Previous Use Code0
Event Type3
Type of Report3

Device Details

Brand NameTRAILBLAZER TRANSPORT INCUBATOR
Generic NameTRANSPORT INCUBATOR
Product CodeFPL
Date Received1998-04-21
Model NumberTI 100
Catalog NumberNA
Lot NumberNA
ID NumberNA
OperatorHEALTH PROFESSIONAL
Device Availability*
Implant FlagN
Date RemovedA
Device Sequence No1
Device Event Key159055
ManufacturerHILL-ROM AIR-SHIELDS
Manufacturer Address330 JACKSONVILLE RD HATBORO PA 19040 US


Patients

Patient NumberTreatmentOutcomeDate
10 1998-04-21

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.