WATERS QUATTRO MICRO VB-QMICRO

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 05 report with the FDA on 2010-05-14 for WATERS QUATTRO MICRO VB-QMICRO manufactured by Waters Corp.

Event Text Entries

[17894501] The customer reported a vacuum roughing pump "caught on fire (wasn't total fire but a lot of smoke). " the pump was unplugged. No injuries were reported.
Patient Sequence No: 1, Text Type: D, B5


[17979294] The vacuum roughing pump is an external component to the mass spectrometer (ms) instrument. The pump is connected to the ms instrument via tubing. A preliminary visual inspection of the pump revealed that the damage was limited to the components inside the pump's electronics box. Additionally, black residue was found on the outside of the pump. Photographs were taken. The pump was removed from the customer's site and a new pump was installed. The pump has been returned to the vendor in the (b)(4) for evaluation. Waters is awaiting the results of the vendor's investigation. A supplemental report will be provided upon completion of the evaluation. "initial use of device" was checked. The ms instrument is capital equipment and was new when installed at the customer site.
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number9616673-2010-00002
MDR Report Key1701186
Report Source05
Date Received2010-05-14
Date of Report2010-05-13
Date of Event2010-04-26
Date Mfgr Received2010-04-26
Date Added to Maude2011-03-30
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer ContactKATHLEEN MORAHAN
Manufacturer Street34 MAPLE ST
Manufacturer CityMILFORD MA 01757
Manufacturer CountryUS
Manufacturer Postal01757
Manufacturer Phone5084823574
Single Use3
Remedial ActionRL
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameWATERS QUATTRO MICRO
Generic NameDOP, MASS SPECTROMETER, CLINICAL USE
Product CodeDOP
Date Received2010-05-14
Returned To Mfg2010-04-30
Model NumberQUATTRO MICRO
Catalog NumberVB-QMICRO
Lot NumberNA
ID NumberNA
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device AgeDA
Device Eval'ed by MfgrN
Device Sequence No1
Device Event Key0
ManufacturerWATERS CORP
Manufacturer Address34 MAPLE ST MILFORD MA 01757 US 01757


Patients

Patient NumberTreatmentOutcomeDate
10 2010-05-14

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.