BENGAY MOIST HEAT THERAPY

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 04 report with the FDA on 2010-08-31 for BENGAY MOIST HEAT THERAPY manufactured by Johnson And Johnson Group Of Consumer Companies.

Event Text Entries

[1473718] This report contains both initial and additional info received on (b)(6) 2010 and (b)(6) 2010 respectively. This was a spontaneous report received from a (b)(6) female consumer reporting on herself. The consumer used two bengay moist heat therapy pads (no active ingredient) daily during the day time beginning on (b)(6) 2010 for pain and bengay pain relief and massage (menthol) nightly beginning on (b)(6) 2010 for pain. On (b)(6) 2010, her skin burnt to a few levels inside of the skin, she had water boils from her head to feet describes as chickenpox, she was unable to walk for a week, and she was in pain because her whole skin was burned. On an unk date, she went to the physician who prescribed an unspecified medication. On unk dates, she lost a week of work. On (b)(6) 2010, use of both products was discontinued. As of (b)(6) 2010, the outcome of the events was reported as not resolved.
Patient Sequence No: 1, Text Type: D, B5


[8702426] At this time, the device has not been returned for failure analysis / laboratory testing. Therefore, no causal association or conclusion can be determined.
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number2246407-2010-00003
MDR Report Key1837378
Report Source04
Date Received2010-08-31
Date of Report2010-08-23
Date of Event2010-07-22
Date Mfgr Received2010-08-23
Date Added to Maude2011-03-17
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag0
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer Street185 TABOR RD
Manufacturer CityMORRIS PLAINS NJ 07950
Manufacturer CountryUS
Manufacturer Postal07950
Manufacturer Phone2153257685
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameBENGAY MOIST HEAT THERAPY
Generic NamePACK, HOT OR COLD, DISPOSABLE
Product CodeOMW
Date Received2010-08-31
Device AvailabilityN
Device AgeDA
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerJOHNSON AND JOHNSON GROUP OF CONSUMER COMPANIES
Manufacturer AddressMORRIS PLAINS NJ 07950 US 07950


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2010-08-31

© 2026 FDA.report