COBAS 6000 CORE 05036453001

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 05,06 report with the FDA on 2011-04-13 for COBAS 6000 CORE 05036453001 manufactured by Roche Diagnostics.

Event Text Entries

[1877571] The customer received intermittent questionable results for multiple assays for approximately one week. The assays involved were alanine aminotransferase, aspartate aminotransferase, bicarbonate and calcium. The issue involved an unknown number of patients and occurred when the reagent packs were low (less than 30 tests). The customer provided results for eight patient samples. The alanine aminotransferase without pyridoxal phosphate activation (alt) results for one sample were discrepant. The initial alt result was 1 u/l and was reported outside the laboratory. The sample was repeated on an integra 400 and recovered 79 u/l. This result was sent outside the laboratory in a corrected report. The patient was not adversely affected by the event. The alt reagent lot number was 63220401. The field service representative determined a reagent sampling issue was the cause. He cleaned and lubricated the x drive assembly for the r2 probe. He reinstalled the r2 syringe barrel and performed all probe alignments. All diagnostics and customer's controls were acceptable.
Patient Sequence No: 1, Text Type: D, B5


[9172365] .
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number1823260-2011-02038
MDR Report Key2054189
Report Source05,06
Date Received2011-04-13
Date of Report2011-04-13
Date of Event2011-03-29
Date Mfgr Received2011-03-29
Date Added to Maude2011-04-13
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location3
Manufacturer ContactNA RICHEAL CLINE
Manufacturer Street9115 HAGUE ROAD NA
Manufacturer CityINDIANAPOLIS IN 46250
Manufacturer CountryUS
Manufacturer Postal46250
Manufacturer Phone3175213833
Manufacturer G1HITACHI HIGH TECH CORP.
Manufacturer Street882 ICHIGE HITACHINAKA NA
Manufacturer CityIBARAKI 312-8504
Manufacturer Postal Code312-8504
Single Use3
Previous Use Code3
Removal Correction NumberNA
Event Type3
Type of Report3

Device Details

Brand NameCOBAS 6000 CORE
Generic NameCLINICAL CHEMISTRY ANALYZER
Product CodeCKA
Date Received2011-04-13
Model NumberNA
Catalog Number05036453001
Lot NumberNA
ID NumberNA
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerROCHE DIAGNOSTICS
Manufacturer Address9115 HAGUE ROAD NA INDIANAPOLIS IN 46250 US 46250


Patients

Patient NumberTreatmentOutcomeDate
10 2011-04-13

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.