STAT PROFILE CRITICAL CARE XPRESS 37413 37272

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 05 report with the FDA on 2011-03-04 for STAT PROFILE CRITICAL CARE XPRESS 37413 37272 manufactured by Nova Biomedical.

Event Text Entries

[1870934] Per the customer, a patient whole blood samples that were analyzed on a specific critical care xpress analyzer were recovering ionized calcium results that were clinically significantly lower than other critical care xpress analyzers within the same laboratory. Result comparison: affected analyzer: 0. 62; other analyzer in lab: 1. 22; affected analyzer: 0. 57; other analyzer in lab: 1. 24; affected analyzer: 0. 58, other analyzer in lab: 1. 18. Quality control results on applicable analyzers were in compliance. The patient's results were reported but no action was done for patient based on the results. A support call was performed on the affected analyzer which included replacement of the ionized calcium sensor. All comparisons were acceptable. The calcium sensor from the affected analyzer was returned to nova biomedical for investigation. The investigation did not confirm the complaint of low whole blood calcium results. As of (b)(4) 2011, there have been no further reports from the customer for low calcium results since the support call.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1219029-2011-00002
MDR Report Key2057139
Report Source05
Date Received2011-03-04
Date of Report2011-02-09
Date of Event2011-02-04
Date Mfgr Received2011-02-09
Device Manufacturer Date2010-09-01
Date Added to Maude2011-09-12
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer ContactPAUL MCDONALD, CHIEF Q OFFICER
Manufacturer Street200 PROSPECT ST.
Manufacturer CityWALTHAM MA 02454
Manufacturer CountryUS
Manufacturer Postal02454
Manufacturer Phone7816473700
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameSTAT PROFILE CRITICAL CARE XPRESS
Generic NameBLOOD GAS/ELECTROLYT/METABOLITE ANALYZER
Product CodeJFP
Date Received2011-03-04
Returned To Mfg2011-02-14
Model Number37413
Catalog Number37272
Lot NumberY03110160
Device Expiration Date2011-12-31
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device AgeDA
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerNOVA BIOMEDICAL
Manufacturer Address200 PROSPECT ST. WALTHAM MA 02454 US 02454


Patients

Patient NumberTreatmentOutcomeDate
10 2011-03-04

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.