IMMAGE? 800 IMMUNOCHEMISTRY SYSTEM A15445

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 01,06 report with the FDA on 2011-07-24 for IMMAGE? 800 IMMUNOCHEMISTRY SYSTEM A15445 manufactured by Beckman Coulter, Inc..

Event Text Entries

[2045748] The customer contacted beckman coulter, inc. (bci) to report discrepant patient sample results and a shift in quality control results for rheumatoid factor (rf) assayed on an immage 800 immunochemistry system. The patient results were reported out of the laboratory. It is unknown if there was an impact to patient treatment due to the discrepant rf results. The customer reported discrepant rf patient results for one sample when switching from rf reagent lot # m101863 to rf reagent lot # m007630. The customer reported that quality control results shifted low and were outside of the laboratory's established range when switching to rf reagent lot # m007630. A definitive root cause has not yet been determined for this event.
Patient Sequence No: 1, Text Type: D, B5


[9247922] Reagent lot changed. Discrepant patient results and a shift of quality control results were obtained. A definitive root cause for the event has not yet been determined. The customer initially contacted bci on (b)(6) 2011 to report the shift in quality control results for rf. The customer followed up with a subsequent communication on (b)(6) 2011 to report the discrepant patient results for rf.
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number2050012-2011-03399
MDR Report Key2174175
Report Source01,06
Date Received2011-07-24
Date of Report2011-06-09
Date of Event2011-06-08
Date Mfgr Received2011-06-09
Date Added to Maude2012-04-11
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional0
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer ContactMS. NORA ZEROUNIAN
Manufacturer Street250 S. KRAEMER BLVD.
Manufacturer CityBREA CA 92821
Manufacturer CountryUS
Manufacturer Postal92821
Manufacturer Phone7149613634
Manufacturer G1BECKMAN COULTER, INC.
Manufacturer Street250 S. KRAEMER BLVD.
Manufacturer CityBREA CA 92821
Manufacturer CountryUS
Manufacturer Postal Code92821
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameIMMAGE? 800 IMMUNOCHEMISTRY SYSTEM
Generic NameNEPHELOMETER FOR CLINICAL USE
Product CodeJQX
Date Received2011-07-24
Catalog NumberA15445
Device AvailabilityY
Device Eval'ed by Mfgr*
Device Sequence No1
Device Event Key0
ManufacturerBECKMAN COULTER, INC.
Manufacturer Address250 S. KRAEMER BLVD. BREA CA 92821 US 92821


Patients

Patient NumberTreatmentOutcomeDate
10 2011-07-24

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.