AU400 CLINICAL CHEMISTRY ANALYZER AU403-02E N1254400

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 06 report with the FDA on 2012-01-03 for AU400 CLINICAL CHEMISTRY ANALYZER AU403-02E N1254400 manufactured by Beckman Coulter Mishima K.k..

Event Text Entries

[17102888] The customer reported two erroneous high ethanol results generated on the au400 clinical chemistry analyzer. The results were reported out of the laboratory and questioned by the doctor. Patient treatment was not impacted by this event. Qc out high after event. Prior to the event, the instrument had a new sample probe, new lamp, wash pump replaced, and cuvettes cleaned. Post the event, the customer use a new lot of calibrator and fresh reagent, cleaned water tank, replaced "beaded" water tanks on water system, and cultured cleaned. On (b)(4) 2011, a field service engineer (fse) was unable to replicate as problem is intermittent. Verified all alignments, temperatures and wash usage. All consumables have been replaced. The customer is going to run all alcohols on the au640 in duplicate. On (b)(4) 2011, fse decontaminated the au400 and all qc were within specification. Will monitor. Root cause for the event appears to be the water system and contagion of the au400
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2050012-2012-00016
MDR Report Key2395954
Report Source06
Date Received2012-01-03
Date of Report2011-11-30
Date of Event2011-11-24
Date Mfgr Received2011-11-30
Device Manufacturer Date2002-11-01
Date Added to Maude2012-06-19
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional0
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer ContactMRS. DUNG NGUYEN
Manufacturer Street250 S. KRAEMER BLVD.
Manufacturer CityBREA CA 92821
Manufacturer CountryUS
Manufacturer Postal92821
Manufacturer Phone7149614941
Manufacturer G1BECKMAN COULTER MISHIMA K.K.
Manufacturer Street454-32 HIGASHINO, NAGAIZUMI-CH
Manufacturer CitySUNTO-GUN, SCHIZUOKA, JP-NOTA 411-0931
Manufacturer CountryJA
Manufacturer Postal Code411-0931
Single Use0
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameAU400 CLINICAL CHEMISTRY ANALYZER
Generic NameACID PHOSPHATASE, NAPHTHYL PHOSPHATE
Product CodeCKB
Date Received2012-01-03
Model NumberAU403-02E
Catalog NumberN1254400
Lot NumberN/A
ID NumberN/A
Device AvailabilityY
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerBECKMAN COULTER MISHIMA K.K.
Manufacturer Address454-32 HIGASHINO, NAGAIZUMI-CH SUNTO-GUN, SCHIZUOKA, JP-NOTA 411-0931 JA 411-0931


Patients

Patient NumberTreatmentOutcomeDate
10 2012-01-03

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.