MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 00,01,05 report with the FDA on 2012-01-03 for CELSIOR (ORGAN PRESERVATION SOLUTION) SOLUTION FOR ORGAN PRESERVATION UNK manufactured by Genzyme Polyclonals S.a.s..
[16924797]
After de-clamping, heart did not restart spontaneously [complications of transplanted heart]. Case description: spontaneous report received from a surgeon on (b)(6) 2011 regarding 4 unspecified heart transplant pts, initials not provided. Celsior administration info was not provided. Pt history was not reported. The surgeon reported that in 5 pts the transplanted heart did not restart spontaneously after de-clamping. In 2 of the pts the heart restarted after drug administration. One restarted after extracorporeal membrane oxygenation (ecmo), one pt died, and the last pt was on ecmo at the time of this report. Concomitant medications were not reported. Intensity was not provided. Causal relationship to thymoglobulin was considered possibly related. This is 1 of 5 reports of heart graft dysfunction from this surgeon. The complete list of cases created from this report include (b)(4). Mfr's comment: no further details were received. Further info has been requested.
Patient Sequence No: 1, Text Type: D, B5
Report Number | 2950168-2012-00002 |
MDR Report Key | 2404323 |
Report Source | 00,01,05 |
Date Received | 2012-01-03 |
Date of Report | 2011-12-21 |
Date Mfgr Received | 2011-12-21 |
Date Added to Maude | 2012-01-11 |
Event Key | 0 |
Report Source Code | Manufacturer report |
Manufacturer Link | Y |
Number of Patients in Event | 0 |
Adverse Event Flag | 3 |
Product Problem Flag | 3 |
Reprocessed and Reused Flag | 0 |
Health Professional | 3 |
Initial Report to FDA | 3 |
Report to FDA | 3 |
Event Location | 0 |
Manufacturer Contact | JILL ROBINSON, R, PH, MBA |
Manufacturer Street | 675 WEST KENDALL ST |
Manufacturer City | CAMBRIDGE MA 02142 |
Manufacturer Country | US |
Manufacturer Postal | 02142 |
Manufacturer Phone | 6177689000 |
Manufacturer G1 | GENZYME POLYCLONALS, S.A.S. |
Manufacturer Street | 58 AVE DEBOURG |
Manufacturer City | LYON |
Manufacturer Country | FR |
Single Use | 3 |
Previous Use Code | 3 |
Event Type | 3 |
Type of Report | 3 |
Brand Name | CELSIOR (ORGAN PRESERVATION SOLUTION) SOLUTION FOR ORGAN PRESERVATION |
Generic Name | NONE |
Product Code | MSB |
Date Received | 2012-01-03 |
Model Number | UNK |
Catalog Number | UNK |
Lot Number | UNK |
ID Number | UNK |
Device Age | DA |
Device Eval'ed by Mfgr | * |
Device Sequence No | 1 |
Device Event Key | 0 |
Manufacturer | GENZYME POLYCLONALS S.A.S. |
Manufacturer Address | LYON FR |
Patient Number | Treatment | Outcome | Date |
---|---|---|---|
1 | 0 | 1. Other | 2012-01-03 |