VEINWAVE (DISTRIBUTED BY MEDICAL INNOVATIONS)

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2012-02-05 for VEINWAVE (DISTRIBUTED BY MEDICAL INNOVATIONS) manufactured by Fcare Systems Usa.

Event Text Entries

[21417887] Used veinwave device on nose and face. Pt presented back to office 3 days later with innumerable punctate red marks and lines in treated areas. Unable to get response from us distributor of possible cause and/or recommended therapy. After multiple threatening messages via phone and email, get a response from a company, fcare systems usa who claimed to be mfr of device. Expressed my concern about power output from device and possible disfiguration/scarring. Was told that if pt was only treated once, marks would likely resolve in approx 6 weeks but multiple treatments would result in permanent scarring. Also told that the control board for device could be bad and, therefore, they would need to evaluate device itself. Sent device to fcare who evaluated device and did find faulty control board resulting in maximum output to needle tip resulting in the clinical findings i described. Power control board upgraded from v5 to v6 (according to f/u correspondence from fcare). Expressed my concern about using device on another pt without some reassurance that system would not silently fail again (won't know until pt's returned disfigured). To that end, i asked for some sort of meter or test device to insure power output at needle tip was congruent with stated power on device. Was told that the equipment was too expensive to be used in that manner and therefore, was cost prohibitive. Asked if there was an alternative methodology. Was told to put needle on my own finger and activate. If the feeling was really painful, probably too much power at tip. To date, still can't get a hold of any representative from veincare to report issue or devise a reasonable solution. Have called all the numbers on the brochure, sent correspondence via email and web page contacts as well as registered letter asking for assistance (which was subsequently returned as "address unknown"). Have used this device for almost 7 months prior to this incident with excellent results. Unwilling to use it again, however, without some sort of reassurance from the company that this can't happen again (would rather device fail completely if control board goes bad then disfigure patients). Date of use: (b)(6) 2011. Reason for use: thread vein base of nose and cheeks.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report NumberMW5024172
MDR Report Key2446066
Date Received2012-02-05
Date of Report2012-02-05
Date of Event2011-12-09
Date Added to Maude2012-02-14
Event Key0
Report Source CodeVoluntary report
Manufacturer LinkN
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Single Use0
Previous Use Code0
Event Type3
Type of Report3

Device Details

Brand NameVEINWAVE (DISTRIBUTED BY MEDICAL INNOVATIONS)
Generic NameVEINWAVE
Product CodeONQ
Date Received2012-02-05
Returned To Mfg2011-12-16
Model NumberVEINWAVE
OperatorHEALTH PROFESSIONAL
Device AvailabilityR
Device Sequence No1
Device Event Key0
ManufacturerFCARE SYSTEMS USA
Manufacturer AddressMIAMI SHORES FL 33138 US 33138


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2012-02-05

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.