MAUDE MDR 2475715

MDR report key
2475715
Report number
1058196-2012-00104
Event key
0
Event type
3
Date of event
2012-02-02
Date received
2012-03-02
Adverse event
3
Product problem
3
Patients in event
0
Reporter occupation
0
Health professional
3
Initial report to FDA
3
Event location
0

Manufacturer Contact#

Contact
MRS. LINA ALZATE
Address
MIAMI LAKES FL 33014 US
Phone
786-786-7863
Report source
M
Manufacturer link flag
Y

Devices#

Seq, Brand, Generic table
SeqBrandGenericManufacturerProduct codeModelCatalogLotPMA510(k)ImplantEvaluatedAvailability
1NBCA LIQUID EMBOLIC KITCNV_NBCA (MFE)CORDIS NEUROVASCULAR, INC.KGGNA631XXXUNKR N

Patients#

Sequence, Received, Treatment table
SequenceReceivedTreatmentOutcome
12012-03-020

Event Narratives#

D

Patient 1

DURING A LITERATURE SEARCH, THE FOLLOWING ARTICLE WAS FOUND: JOURNAL OF NEUROINTERVENTIONAL SURGERY MARCH 2011 3 (1) (PP 21-24) "VASCULAR INFLAMMATION WITH EOSINOPHILS AFTER THE USE OF N-BUTYL CYANOACRYLATE LIQUID EMBOLIC SYSTEM," QUINN J.C., MITTAL N., BAISRE A., CHO E.S., SHARER L.R., CANDHI C., PRESTIGIACOMA C.J. THE ARTICLE REPORTED THREE CASES OF RESTRICTED EOSINOPHILIC VASCULITIS SECONDARY TO NBCA SENSITIZATION. THE CASES OF THREE PATIENTS ARE REPORTED WHO UNDERWENT ENDOVASCULAR EMBOLIZATION WITH N-BCA, FOLLOWED BY RESECTION IN TWO AND POST-EMBOLIZATION HEMORRHAGE WITH EMERGENT EVACUATION IN ONE, WITH HISTOLOGIC DEMONSTRATION OF AN EOSINOPHILIC VASCULITIS FOUND IN RESECTED AVM SPECIMENS. THIS IS PROBABLY THE FIRST REPORT OF THIS TISSUE REACTION, WHICH MAY HAVE THEORETICALLY SERIOUS CLINICAL IMPLICATIONS. CLINICAL PRESENTATION: IN THIS SERIES, THREE PATIENTS (2 WOMEN, 1 MAN) PRESENTED WITH INTRACRANIAL AVMS (SPETZLER-MARTIN I-III) WITH THE LESIONS LOCATED IN THE FRONTAL LOBE IN TWO OF THE PATIENTS AND IN THE PARIETAL LOBE IN ONE. ALL PATIENTS PRESENTED WITH HEADACHE, AND ONE ALSO HAD NEW-ONSET SEIZURES. INTERVENTION: ALL PATIENTS UNDERWENT EMBOLIZATION WITH N-BCA BEFORE A PLANNED, STAGED SURGICAL RESECTION OF THE EMBOLIZED AVMS.

N

Patient 1

ONE PATIENT HAD FOUR EMBOLIZATIONS OVER A 5-MONTH PERIOD, ONE HAD THREE EMBOLIZATIONS OVER 3 MONTHS COMPLICATED BY HEMORRHAGE AFTER EMBOLIZATION REQUIRING EMERGENT EVACUATION OF THE HEMATOMA, AND THE THIRD PATIENT HAD A SINGLE EMBOLIZATION. IN ALL THREE PATIENTS, SURGICAL AND AUTOPSY SPECIMENS SHOWED AN INFLAMMATORY RESPONSE WITHIN THE EMBOLIZED VASCULATURE WITH A PROMINENT EOSINOPHILIC INFILTRATE. CONCLUSION: THE EOSINOPHILIC VASCULITIS SEEN IN THE PATHOLOGY SPECIMENS MAY REPRESENT A PREVIOUSLY UNDOCUMENTED HYPERSENSITIVITY REACTION FOLLOWING EXPOSURE TO N-BCA, WITH THE POTENTIAL FOR ADVERSE SEQUELAE, INCLUDING INCREASED RISK OF HEMORRHAGE AS WAS SEEN IN ONE OF OUR PATIENTS. JOURNAL OF NEUROINTERVENTIONAL SURGERY MARCH 2011 3 (1) (PP 21-24) "VASCULAR INFLAMMATION WITH EOSINOPHILS AFTER THE USE OF N-BUTYL CYANOACRYLATE LIQUID EMBOLIC SYSTEM," QUINN J.C., MITTAL N., BAISRE A., CHO E.S., SHARER L.R., CANDHI C., PRESTIGIACOMA C.J. REPORTED THREE CASES OF RESTRICTED EOSINOPHILIC VASCULITIS SECONDARY TO NBCA SENSITIZATION. ONE OF THESE CASES WAS COMPLICATED BY HEMORRHAGE AFTER EMBOLIZATION. ALL THREE PATIENTS PRESENTED WITH HEADACHE. WITH FOLLOW-UP INVESTIGATION, IT WAS REPORTED BY THE CONTACT AUTHOR THAT THE BRAND USED WAS TRUFILL NBCA. CASE 3 REPORTED A WOMAN PRESENTING WITH NEW-ONSET HEADACHE AND VOMITING WAS DIAGNOSED WITH A 2.5CM LEFT PARIETAL AVM (SPETZLERE MARTIN I). THE PATIENT UNDERWENT A SINGLE STAGE TREATMENT WITH N-BCA AT 20% CONCENTRATION IN LIPIODOL TO OCCLUDE A SINGLE PEDICLE. FIVE DAYS LATER, THE PATIENT UNDERWENT A LEFT PARIETAL CRANIOTOMY WITH COMPLETE RESECTION OF THE AVM. THE REMAINDER OF THE HOSPITAL COURSE WAS UNEVENTFUL AND THE PATIENT WAS DISCHARGED WITH NO RESIDUAL NEUROLOGIC DEFICITS. MICROSCOPIC EXAMINATION OF THE SURGICAL SPECIMEN REVEALED A DENSE GRANULOCYTIC INFILTRATE IN BLOOD VESSEL WALLS WITH MANY SCATTERED EOSINOPHILS. BLOOD EXAMINATION DID NOT SHOW EVIDENCE OF PERIPHERAL EOSINOPHILIA OR SIGNS OF SYSTEMIC VASCULITIS. SOME 158 PATIENTS WITH VARYING GRADES OF AVMS WERE TREATED WITH N-BCA EMBOLIZATION, FOLLOWED BY OPEN RESECTION BETWEEN 2002 AND 2008. ALL SPECIMENS OBTAINED DURING RESECTION WERE SENT FOR PATHOLOGIC REVIEW. HISTOPATHOLOGIC EXAMINATION OF THE AVMS DEMONSTRATED THE HISTOPATHOLOGIC PROGRESSION AS HAS BEEN PREVIOUSLY DESCRIBED. UNIQUE TO THIS SERIES OF THREE PATIENTS AMONG THE 158 CASES REVIEWED WAS THE PRESENCE OF A PROMINENT EOSINOPHILIC INFILTRATE AFFECTING THE ENDOTHELIUM AND EXTENDING INTO THE MEDIA OF THE EMBOLIZED VESSELS, SUGGESTING A SEPARATE INFLAMMATORY/IMMUNOLOGICAL PROCESS IN ADDITION TO THE NATURAL PROGRESSION WHICH HAS BEEN PREVIOUSLY DESCRIBED. OTHER PORTIONS OF THE NON-EMBOLIZED AVM DID SHOW A SIMILAR EOSINOPHILIC INFILTRATE, ARGUING THAT THIS IS PROBABLY A NON-FOCAL REACTION. IN ALL CASES, THERE WAS NO EVIDENCE OF PERIPHERAL EOSINOPHILIA OR ANY CLINICAL SIGNS OF AN UNDERLYING SYSTEMIC CAUSE FOR A CNS RESTRICTED EOSINOPHILIC INFILTRATE, ALTHOUGH DEDICATED SEROLOGIC TESTING WAS NOT DONE IN THESE PATIENTS. THE PRESENCE OF EOSINOPHILS IN THE CHRONIC INFLAMMATORY MILIEU PROBABLY REPRESENTS A RESTRICTED EOSINOPHILIC VASCULITIS CAUSED BY HOST SENSITIZATION TO N-BCA EPITOPES. THE ARTICLE STATES THAT THE CLINICAL CONSEQUENCES OF THE REPORTED INFLAMMATORY/IMMUNOLOGICAL RESPONSE ARE DIFFICULT TO ASSESS IN THE SERIES FOR A NUMBER OF REASONS, INCLUDING THE PATIENT HAD BASELINE NEUROLOGICAL DEFICITS FROM THEIR PRIMARY VASCULAR MALFORMATIONS, THE EXPOSURE TIME TO NBCA WAS RELATIVELY SHORT, AND FOR TWO PATIENTS, ALL EMBOLIZED VASCULATURE WAS RESECTED DURING THE STATED SURGICAL PROCEDURE. IT FURTHER REPORTS THAT BECAUSE THIS REACTION WAS DESCRIBED IN PATIENTS IN WHOM A STAGED RESECTION WAS PLANNED, IT IS ENTIRELY POSSIBLE THAT THE CLINICAL SEQUEL OF N-BCA EXPOSURE DID NOT HAVE TIME TO MANIFEST ITSELF. IT IS REPORTED THAT THE IMPLICATIONS OF THESE FINDINGS MAY BE MORE RELEVANT IN CASES WHERE N-BCA EMBOLIZATION IS TO BE USED AS A MONOTHERAPY OR IN CASES WHERE NOT ALL THE EMBOLIC AGENT IS FULLY RESECTED. THE AUTHORS HYPOTHESIZE THAT THE THREE CASES OF RESTRICTED EOSINOPHILIC VASCULITIS ARE SECONDARY TO N-BCA SENSITIZATION AND THAT THEY BELIEVE THIS MAY REPRESENT A RARE BUT SIGNIFICANT REACTION IN SOME PATIENTS AND HAS THE POTENTIAL TO LEAD TO INCREASED RUPTURE RISK AND, POTENTIALLY, OTHER NEUROLOGICAL SEQUELAE. THE PRODUCT IS NOT AVAILABLE FOR EVALUATION AND TESTING. ADDITIONAL INFORMATION WILL BE SUBMITTED WITHIN 30 DAYS UPON RECEIPT. THIS IS ONE OF FOUR PRODUCTS REPORTED IN THE SAME JOURNAL ARTICLE/LITERATURE SEARCH. PLEASE REFERENCE MFR REPORTS # 1058196-2012-00101; # 1058196-2012-00102; # 1058196-2012-00103; AND # 1058196-2012-00104.

N

Patient 1

PLEASE NOTE THAT THE PRODUCT CATALOG NUMBER WAS CORRECTED. JOURNAL OF NEUROINTERVENTIONAL SURGERY MARCH 2011 3 (1) (PP 21-24) "VASCULAR INFLAMMATION WITH EOSINOPHILS AFTER THE USE OF N-BUTYL CYANOACRYLATE LIQUID EMBOLIC SYSTEM", QUINN J.C., MITTAL N., BAISRE A., CHO E.S., SHARER L.R., CANDHI C., PRESTIGIACOMA C.J. REPORTED THREE CASES OF RESTRICTED EOSINOPHILIC VASCULITIS SECONDARY TO NBCA SENSITIZATION. ONE OF THESE CASES WAS COMPLICATED BY HEMORRHAGE AFTER EMBOLIZATION. ALL THREE PATIENTS PRESENTED WITH HEADACHE. WITH FOLLOW-UP INVESTIGATION IT WAS REPORTED BY THE CONTACT AUTHOR THAT THE BRAND USED WAS TRUFILL NBCA. THIS WOMAN, (B)(6), PRESENTING WITH NEW-ONSET HEADACHE AND VOMITING WAS DIAGNOSED WITH A 2.5 CM LEFT PARIETAL AVM (SPETZLERE MARTIN I). THE PATIENT UNDERWENT A SINGLE STAGE TREATMENT WITH N-BCA AT 20% CONCENTRATION IN LIPIODOL TO OCCLUDE A SINGLE PEDICLE. (B)(6) DAYS LATER, THE PATIENT UNDERWENT A LEFT PARIETAL CRANIOTOMY WITH COMPLETE RESECTION OF THE AVM. THE REMAINDER OF THE HOSPITAL COURSE WAS UNEVENTFUL AND THE PATIENT WAS DISCHARGED WITH NO RESIDUAL NEUROLOGIC DEFICITS. MICROSCOPIC EXAMINATION OF THE SURGICAL SPECIMEN REVEALED A DENSE GRANULOCYTIC INFILTRATE IN BLOOD VESSEL WALLS WITH MANY SCATTERED EOSINOPHILS. BLOOD EXAMINATION DID NOT SHOW EVIDENCE OF PERIPHERAL EOSINOPHILIA OR SIGNS OF SYSTEMIC VASCULITIS. 158 PATIENTS WITH VARYING GRADES OF AVMS WERE TREATED WITH N-BCA EMBOLIZATION, FOLLOWED BY OPEN RESECTION BETWEEN 2002 AND 2008. ALL SPECIMENS OBTAINED DURING RESECTION WERE SENT FOR PATHOLOGIC REVIEW. HISTOPATHOLOGIC EXAMINATION OF THE AVMS DEMONSTRATED THE HISTOPATHOLOGIC PROGRESSION AS HAS BEEN PREVIOUSLY DESCRIBED. UNIQUE TO THIS SERIES OF THREE PATIENTS AMONG THE 158 CASES REVIEWED, WAS THE PRESENCE OF A PROMINENT EOSINOPHILIC INFILTRATE AFFECTING THE ENDOTHELIUM AND EXTENDING INTO THE MEDIA OF THE EMBOLIZED VESSELS, SUGGESTING A SEPARATE INFLAMMATORY/IMMUNOLOGICAL PROCESS IN ADDITION TO THE NATURAL PROGRESSION WHICH HAS BEEN PREVIOUSLY DESCRIBED. OTHER PORTIONS OF THE NON-EMBOLIZED AVM DID SHOW A SIMILAR EOSINOPHILIC INFILTRATE, ARGUING THAT THIS IS PROBABLY A NON-FOCAL REACTION. IN ALL CASES THERE WAS NO EVIDENCE OF PERIPHERAL EOSINOPHILIA OR ANY CLINICAL SIGNS OF AN UNDERLYING SYSTEMIC CAUSE FOR A CNS RESTRICTED EOSINOPHILIC INFILTRATE, ALTHOUGH DEDICATED SEROLOGIC TESTING WAS NOT DONE IN THESE PATIENTS. THE PRESENCE OF EOSINOPHILS IN THE CHRONIC INFLAMMATORY MILIEU PROBABLY REPRESENTS A RESTRICTED EOSINOPHILIC VASCULITIS CAUSED BY HOST SENSITIZATION TO N-BCA EPITOPES. THE ARTICLE STATES THAT THE CLINICAL CONSEQUENCES OF THE REPORTED INFLAMMATORY/IMMUNOLOGICAL RESPONSE ARE DIFFICULT TO ASSESS IN THE SERIES FOR A NUMBER OF REASONS, INCLUDING THE PATIENT HAD BASELINE NEUROLOGICAL DEFICITS FROM THEIR PRIMARY VASCULAR MALFORMATIONS, THE EXPOSURE TIME TO NBCA WAS RELATIVELY SHORT, AND FOR TWO PATIENTS, ALL EMBOLIZED VASCULATURE WAS RESECTED DURING THE STATED SURGICAL PROCEDURE. IT FURTHER REPORTS THAT BECAUSE THIS REACTION WAS DESCRIBED IN PATIENTS IN WHOM A STAGED RESECTION WAS PLANNED, IT IS ENTIRELY POSSIBLE THAT THE CLINICAL SEQUEL OF N-BCA EXPOSURE DID NOT HAVE TIME TO MANIFEST ITSELF. IT IS REPORTED THAT THE IMPLICATIONS OF THESE FINDINGS MAY BE MORE RELEVANT IN CASES WHERE N-BCA EMBOLIZATION IS TO BE USED AS A MONOTHERAPY OR IN CASES WHERE NOT ALL THE EMBOLIC AGENT IS FULLY RESECTED. THE AUTHORS HYPOTHESIZE THAT THE THREE CASES OF RESTRICTED EOSINOPHILIC VASCULITIS ARE SECONDARY TO N-BCA SENSITIZATION AND THAT THEY BELIEVE THIS MAY REPRESENT A RARE, BUT SIGNIFICANT REACTION IN SOME PATIENTS HAS THE POTENTIAL TO LEAD TO INCREASED RUPTURE RISK AND, POTENTIALLY, OTHER NEUROLOGICAL SEQUELAE. THE PRODUCT WAS NOT RETURNED FOR INSPECTION. THE LOT NUMBER OF THE TRUFILL NBCA USED IN THE PROCEDURE IS NOT KNOWN; THEREFORE A DEVICE HISTORY RECORD REVIEW CANNOT BE COMPLETED. THE AUTHORS REPORT THAT THE IMPLICATIONS OF THE FINDINGS OF EOSINOPHILIC VASCULITIS MAY BE MORE RELEVANT IN CASES WHERE N-BCA EMBOLIZATIONS IS TO BE USED AS A MONOTHERAPY OR IN CASES WHERE NOT ALL THE EMBOLIC AGENT IS FULLY RESECTED. THE INSTRUCTIONS FOR USE OUTLINES THAT TRUFILL NBCA LIQUID EMBOLIC SYSTEM IS INDICATED FOR THE EMBOLIZATION OF CEREBRAL AVMS WHEN PRESURGICAL DEVASCULARIZATION IS DESIRED. IT FURTHER WARNS THAT THE SAFETY AND EFFICACY OF THIS PRODUCT AS A LONG-TERM IMPLANT HAS NOT BEEN ESTABLISHED. IT IS CONTRAINDICATED FOR USE WITH PREVIOUS HISTORY OF REACTIONS TO COMPONENTS. THERE ARE NO INDICATIONS OF ANY DEVICE MANUFACTURING ISSUES RELATED TO THE EVENT. INFECTION/INFLAMMATION ARE OUTLINED IN THE INSTRUCTIONS FOR USE AS ADVERSE EVENTS THAT MAY BE ASSOCIATED WITH EMBOLIZATION PROCEDURES (INCLUDING THOSE OBSERVED DURING THE CLINICAL STUDY), AND MAY OCCUR AT ANY TIME DURING OR AFTER THE PROCEDURE. THEREFORE, NO CORRECTIVE ACTIONS WILL BE TAKEN AT THIS TIME.