VITROS 5,1 FS CHEMISTRY SYSTEM 6801375

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 05 report with the FDA on 2012-04-11 for VITROS 5,1 FS CHEMISTRY SYSTEM 6801375 manufactured by Ortho-clinical Diagnostics.

Event Text Entries

[21765008] A customer observed higher than expected and imprecise vitros phyt quality control results obtained from two different vitros performance verifier control fluids on a vitros 5,1 fs chemistry system. Tdm performance verifier lot d9984: 11. 53 ug/ml vs. The established customer mean of 9. 0. Tdm performance verifier lot f9986: 37. 98, >40. 0, >40. 0, >40. 0, and 37. 27 ug/ml vs. The established customer mean of 29. 09. Biased results of the magnitude and direction observed may lead to inappropriate physician action if patient samples were affected. Patient samples were not tested for vitros phyt while quality control results were outside of expected ranges. There was no report of patient harm as a result of this event. (b)(4).
Patient Sequence No: 1, Text Type: D, B5


[21925978] The investigation determined higher than expected and imprecise vitros phyt quality control results were obtained from two different vitros performance verifier control fluids on a vitros 5,1 fs chemistry system. The root cause of this event is analyzer related. Phyt performance tests were outside of ocd guidelines on two different phyt reagent lots. Ocd field service performed service actions to reflectometer and immuno-wash subsystems of the 5,1 fs analyzer. Acceptable vitros phyt performance was observed after service actions were completed. The investigation found no evidence the vitros phyt reagent malfunctioned.
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number1319681-2012-00065
MDR Report Key2528033
Report Source05
Date Received2012-04-11
Date of Report2012-04-11
Date of Event2012-02-17
Date Mfgr Received2012-03-14
Device Manufacturer Date2007-11-09
Date Added to Maude2012-04-12
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer ContactMR. JOSEPH FALVO
Manufacturer Street100 INDIGO CREEK DRIVE
Manufacturer CityROCHESTER NY 14626
Manufacturer CountryUS
Manufacturer Postal14626
Manufacturer Phone5854533000
Manufacturer G1ORTHO-CLINICAL DIAGNOSTICS
Manufacturer Street100 INDIGO CREEK DRIVE
Manufacturer CityROCHESTER NY 14626
Manufacturer CountryUS
Manufacturer Postal Code14626
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameVITROS 5,1 FS CHEMISTRY SYSTEM
Generic NameCHEMISTRY ANALYZER
Product CodeDKH
Date Received2012-04-11
Catalog Number6801375
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerORTHO-CLINICAL DIAGNOSTICS
Manufacturer Address100 INDIGO CREEK DRIVE ROCHESTER NY 14626 US 14626


Patients

Patient NumberTreatmentOutcomeDate
10 2012-04-11

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.