IMMAGE? 800 IMMUNOCHEMISTRY SYSTEM IMMAGE 800 A15445

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 01,05,06 report with the FDA on 2012-08-01 for IMMAGE? 800 IMMUNOCHEMISTRY SYSTEM IMMAGE 800 A15445 manufactured by Beckman Coulter, Inc..

Event Text Entries

[2735124] A customer reported to beckman coulter, inc. (bec) that the cuvettes on immage 800 immunochemistry system were overflowing during the cuvette wash operation. The customer stated that patient results have been reported out, but did not provide any details. The customer indicated the samples were run on another immage system and the results were different. It is unknown if there were any changes to patient treatment attributed or connected to this event. The operator was wearing gloves and lab coat. The operator did not seek medical attention, and no injury was reported. A field service engineer (fse) visited the site on (b)(4) 2012. The fse checked wash head, wash line filter, and vacuum pump. The fse replaced wash line filter, waste canister filter, and all cuvettes. The fse aligned wash head and cranes. The fse ran calibration and controls. The issue was resolved.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2050012-2012-01631
MDR Report Key2678467
Report Source01,05,06
Date Received2012-08-01
Date of Report2012-07-11
Date of Event2012-07-11
Date Mfgr Received2012-07-11
Device Manufacturer Date2008-03-18
Date Added to Maude2012-11-23
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer ContactMS. DUNG NGUYEN
Manufacturer Street250 S. KRAEMER BLVD
Manufacturer CityBREA CA 92821
Manufacturer CountryUS
Manufacturer Postal92821
Manufacturer Phone7149614941
Manufacturer G1BECKMAN COULTER, INC
Manufacturer Street250 S KRAEMER BLVD
Manufacturer CityBREA CA 92821
Manufacturer CountryUS
Manufacturer Postal Code92821
Single Use3
Previous Use Code3
Removal Correction NumberNA
Event Type3
Type of Report3

Device Details

Brand NameIMMAGE? 800 IMMUNOCHEMISTRY SYSTEM
Generic NameNEPHELOMETER, FOR CLINICAL USE
Product CodeJQX
Date Received2012-08-01
Model NumberIMMAGE 800
Catalog NumberA15445
Lot NumberNA
ID NumberSOFTWARE V. 2.0
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerBECKMAN COULTER, INC.
Manufacturer Address250 S KRAEMER BLVD BREA CA 92821 US 92821


Patients

Patient NumberTreatmentOutcomeDate
10 2012-08-01