MAUDE MDR 2826349

MDR report key
2826349
Report number
1119779-2012-00017
Event key
0
Event type
3
Date of event
2012-10-01
Date received
2012-10-31
Adverse event
3
Product problem
3
Patients in event
0
Reporter occupation
100
Health professional
3
Initial report to FDA
3
Event location
0

Manufacturer Contact#

Contact
GAIL CLAIBORNE
Address
7 LOVETON CIR. SPARKS MD 21152 US
Phone
410-410-4103
Report source
M
Manufacturer link flag
Y

Devices#

Seq, Brand, Generic table
SeqBrandGenericManufacturerProduct codeModelCatalogLotPMA510(k)ImplantEvaluatedAvailability
1BBL BHI BROTH WITH FILDES ENRICHMENTBD MICROBIOLOGY SSYTEMSJSG2977821165351R N

Patients#

Sequence, Received, Treatment table
SequenceReceivedTreatmentOutcome
12012-10-3101. O

Event Narratives#

D

Patient 1

CUSTOMER CALLED TO REPORT THAT THEY HAVE BEEN HAVING AN ONGOING CONTAMINATION EVENT WITH TWO LIQUID PRODUCTS FROM BD. THE CUSTOMER IS SEEING CONTAMINATION WITH CANDIDA PARAPSILOSIS. THEY HAVE BEEN HAVING THIS ISSUE FOR SEVERAL MONTHS WITHOUT BEING ABLE TO TRACK THE SOURCE BUT DID NOT PROVIDE SPECIFIC DATING. THE COMMON ELEMENT IS THE USE OF BD THIOGLYCOLLATE BROTH AND BRAIN HEART INFUSION BROTH. NO CONTAMINATION WAS SEEN ON THE GRAM STAIN OR ON THE ORIGINAL MEDIA PLATES. THE CONTAMINATION WAS SEEN AFTER THE INOCULATION OF THE TUBES. CUSTOMER'S PROCESS IS TO INOCULATE THE BHI, THEN INOCULATE THE BHI SUSPENSION INTO THE THIOGLYCOLLATE. THE CUSTOMER DOES NOT KNOW THE NUMBER OF PATIENTS THAT WERE AFFECTED OR SPECIFIC LOT NUMBERS OF PRODUCT, BUT STATES THAT (B)(4) PATIENTS IN TOTAL WERE AFFECTED THROUGHOUT ALL OF THE LOTS. THE AFFECTED SPECIMENS WERE PRIMARILY FROM STERILE SITES BUT THE CUSTOMER COULD NOT PROVIDE FURTHER DETAILS. THE SPECIMENS WERE COLLECTED AT THE SAME FACILITY IN THE OPERATING ROOM OR ER. THE AFFECTED PATIENTS WERE INITIALLY TREATED WITH ANTIFUNGAL MEDICATION. NO FURTHER INFORMATION IS AVAILABLE. THESE ISSUES WILL BE DOCUMENTED ON MDRS 1119779-2012-00013 TO 1119779-2012-00019.

N

Patient 1

THE CUSTOMER HAS EVALUATED THE STAFF'S SPECIMEN PROCESSING PROCEDURE AND SWABBED VARIOUS AREAS OF THE LAB, STAFF AND OPERATING ROOM. HE STATES THAT THE STAFF'S PROCESSING WAS WITHIN PROTOCOL AND THE CONTAMINATE DID NOT GROW FROM THE ENVIRONMENTAL SAMPLES THAT HE TOOK. THE CUSTOMER ALSO STATED THAT THEY ARE REAUTOCLAVING THE MEDIA AND HAVE NOT SEEN FURTHER CONTAMINATION. CUSTOMER WAS MADE AWARE AT THIS TIME THAT THE MEDIA IS NOT VALIDATED FOR ADDITIONAL AUTOCLAVE CYCLES AND MAY FAIL TO FUNCTION AS INTENDED. CUSTOMER ALSO RULED OUT THEIR STERILE PIPETTES AND SWABS AS POSSIBLE SOURCES. THE BATCH HISTORY RECORD WAS REVIEWED AND NO ANOMALIES WERE NOTED. ALL RESULTS WERE SATISFACTORY. NO RETURNS WERE RECEIVED. RETENTION SAMPLES WERE EXAMINED FOR DEFECTS, SPECIFICALLY FOR CONTAMINATION. ALL TUBES APPEAR SATISFACTORILY UPON VISUAL INSPECTION. TWO TUBES WERE ALSO FILTERED BY MEMBRANE FILTRATION AND INCUBATED. MEDIA WAS INCUBATED AT 20-25CC AND 30-25CC WITH NO CONTAMINATION/GROWTH NOTED. NO TRENDS HAVE BEEN NOTED TO DATE IN THE LOTS REPORTED BY THE CUSTOMER. MDRS WERE GENERATED ON EACH LOT OF MEDIA REPORTED BY THIS SINGLE CUSTOMER AS THE CUSTOMER WAS UNABLE TO DISTINGUISH WHICH LOT WAS USED WHEN A POTENTIAL FALSE RESULT WAS REPORTED.