ARTISTE MV SYSTEM 08139789 NA

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 01,05,07 report with the FDA on 2012-12-11 for ARTISTE MV SYSTEM 08139789 NA manufactured by Siemens Medical Solutions Usa, Inc., Radiation Oncology.

Event Text Entries

[3304497] Siemens was notified on (b)(6) 2012 that the 333 was the position information on the table interface when the table was in the physical 0 degree position. The position readout changed when doing isocentric rotation. It behaved exactly like someone had rotated the table to 333 degrees and done a calibration saying this is zero. Reportedly the therapist had transferred patient data from (b)(4) to rt therapist and downloaded the first field to the accelerator. The requested isocentric rotation for the treatment field was zero. When the therapists were in the treatment room and pushed the button for auto-setup, the table moved isocentric even though the table was physically correct at zero (0) degrees. Then it was noticed that the readout display showed 333 when the physical position was at zero (0) degrees. There was no error message. The table had to be re-calibrated to bet the correct readout. There is no report of injury to the patient. This reported issue occurred in (b)(6).
Patient Sequence No: 1, Text Type: D, B5


[10349970] Siemen? S investigation into the reported incident is on-going. A supplemental report will be sent to the fda upon completion of the investigation. (b)(6).
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number2910081-2012-10524
MDR Report Key2917640
Report Source01,05,07
Date Received2012-12-11
Date of Report2012-11-12
Date of Event2012-10-23
Date Mfgr Received2012-11-12
Date Added to Maude2013-03-15
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer ContactMARLYNNE GALLOWAY
Manufacturer Street51 VALLEY STREAM PKWY. MS D02
Manufacturer CityMALVERN PA 19355
Manufacturer CountryUS
Manufacturer Postal19355
Manufacturer Phone6102195361
Manufacturer G1SIEMENS MEDICAL SOLUTIONS USA, INC.
Manufacturer Street4040 NELSON AVE.
Manufacturer CityCONCORD CA 94520
Manufacturer CountryUS
Manufacturer Postal Code94520
Single Use0
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameARTISTE MV SYSTEM
Generic NameACCELERATOR, LINEAR, MEDICAL
Product CodeJAI
Date Received2012-12-11
Model Number08139789
Catalog NumberNA
Lot NumberNA
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device AgeDA
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerSIEMENS MEDICAL SOLUTIONS USA, INC., RADIATION ONCOLOGY
Manufacturer Address4040 NELSON AVE. CONCORD CA 94520 US 94520


Patients

Patient NumberTreatmentOutcomeDate
10 2012-12-11

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.