BOSTON SCIENTIFIC / TARGET THERAPEUTICS GDC 18-SOFT 351615-4

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2002-04-18 for BOSTON SCIENTIFIC / TARGET THERAPEUTICS GDC 18-SOFT 351615-4 manufactured by Target Therapeutics/boston Scientific.

Event Text Entries

[19152414] Premature detachment of boston scientific/target therapeutics gdc embolization coil. The pt had an occlusive dissection of the internal carotid artery with an associated pseudoaneurysm. A cordis prowler 14 microcatheter was placed inside the pseudoaneurysm prior to deployment of two cordis precise stents to reopen the lumen of the carotid artery. A target therapeutics gdc 18-soft 6 x 15 mm coil, lot #4457610, ref #351615-1 was then prepped and placed into the microcatheter for embolization of the pseudoaneurysm. Midway through the microcatheter on the initial placement attempt the coil became very difficult to push. On withdrawal of the pusher wire it was apparent that the coil had detached prematurely from the pusher wire. The microcatheter was withdrawn with the coil still lodged inside. A second catheter was placed in the pseudoaneurysm which was subsequently coiled with good result. There was no clinical complications associated with this event. The catheter and coil have been sent to target therapeutics for evaluation.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report NumberMW1024813
MDR Report Key390244
Date Received2002-04-18
Date of Report2002-04-18
Date of Event2002-03-26
Date Added to Maude2002-04-29
Event Key0
Report Source CodeVoluntary report
Manufacturer LinkN
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag0
Health Professional3
Initial Report to FDA0
Report to FDA0
Event Location3
Single Use0
Previous Use Code0
Event Type3
Type of Report3

Device Details

Brand NameBOSTON SCIENTIFIC / TARGET THERAPEUTICS
Generic NameGDC 18-SOFT PLATINUM EMBOLIZATION COIL
Product CodeHDC
Date Received2002-04-18
Returned To Mfg2002-04-18
Model NumberGDC 18-SOFT
Catalog Number351615-4
Lot Number4457610
ID Number*
Device Expiration Date2004-11-30
OperatorHEALTH PROFESSIONAL
Device AvailabilityR
Implant FlagN
Date Removed*
Device Sequence No1
Device Event Key379291
ManufacturerTARGET THERAPEUTICS/BOSTON SCIENTIFIC
Manufacturer Address47900 BAYSIDE PKWY FREMONT CA 945386515 US


Patients

Patient NumberTreatmentOutcomeDate
10 2002-04-18

© 2026 FDA.report