TEKTONE TC400, TC400P5

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 07 report with the FDA on 2014-11-21 for TEKTONE TC400, TC400P5 manufactured by Tektone Sound & Signal Manufacturing, Inc..

Event Text Entries

[5112003] On (b)(6) 2014, (b)(6) reported that the master stations of the nurse call system were annunciating calls from some stations, and this did not generate a 'fault' condition. An updated version of software was installed on the system (b)(6) 2014. To date the problem has not re-occurred.
Patient Sequence No: 1, Text Type: D, B5


[12677435] Root cause: we believe a counting semaphore in the tc400 code caused the central equipment to stop polling. We determined this from the data received from our diagnostics tools on-site. Corrective action: we determined through testing that the counting semaphore is no longer needed and removed it from the system firmware. Validation: because we've not been able to duplicate the problem in house, we placed the code on-site at (b)(6). To date the original problem has not re-occurred. Preventive action: we added 'polling fault' code to the os software. This will alert the user should the nurse call system again become unresponsive.
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number3001757821-2014-00002
MDR Report Key4369890
Report Source07
Date Received2014-11-21
Date of Report2014-09-17
Date of Event2014-09-11
Device Manufacturer Date2013-01-01
Date Added to Maude2015-01-12
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag0
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer Street277 INDUSTRIAL PARK RD.
Manufacturer CityFRANKLIN NC 28734
Manufacturer CountryUS
Manufacturer Postal28734
Manufacturer Phone8285244013
Single Use0
Remedial ActionOT
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameTEKTONE
Generic NameNURSE CALL SYSTEM
Product CodeIQA
Date Received2014-11-21
Model NumberTC400, TC400P5
OperatorHEALTH PROFESSIONAL
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerTEKTONE SOUND & SIGNAL MANUFACTURING, INC.
Manufacturer Address277 INDUSTRIAL PARK RD. FRANKLIN NC 28734 US 28734


Patients

Patient NumberTreatmentOutcomeDate
10 2014-11-21

© 2024 FDA.report