HYGEIA FLANGE

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 00 report with the FDA on 2015-04-17 for HYGEIA FLANGE manufactured by Hygeia Ii Medical Group, Inc..

Event Text Entries

[18921201] The customer contacted our customer service representative on (b)(6) 2015 stating that the customer believes that the customers flanges were not the right side. The customer stated that the customers nipples have been started bleeding and not because of the nipples being chapped, but by the nipples getting cut by the flange. Inside the flange, there is a half moon shape that allows the milk to drain into the flange chamber and then into the collection container. The customer stated that the customer believes this is where the cuts were occurring. The first time it occurred was about 6 weeks prior to the customers (b)(6) 2015 phone call, and then again on (b)(6) 2015 when the customer contacted our customer service representative. The customer was using a medium size flange.
Patient Sequence No: 1, Text Type: D, B5


[19065167] Marketing material includes instructions on what size flange customers to use. There is a video that explains the flange size selection of hygeia's (b)(6) channel, as well as under the faq section of the hygeia website. Properly fitting flanges are important for both comfort and efficient breast pumping. While breast pumping, your nipple should move freely in and out of the flange tunnel, and there should be no rubbing or sticking on the sides or back of the flange. If a customer should feel any discomfort or pain while breast pumping, it is often a sign that you need a larger flange. Nipple blanching at the base of the nipple while breast pumping is another indicator that the flange may be too small. Flange sizes are not related to the customer's breast size, but rather the size of the customer's nipple. Investigation was found that the customer had ordered the incorrect size flange. Our customer service representative sent the customer size large flanges. Customer service followed-up with the customer, and by using size large flanges resolved the issue.
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number3006774448-2015-00001
MDR Report Key4713506
Report Source00
Date Received2015-04-17
Date of Report2015-04-17
Date of Event2015-03-18
Date Mfgr Received2015-03-18
Date Added to Maude2015-04-22
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer ContactJOHN GHERMAN
Manufacturer Street6005 HIDDEN VALLEY ROAD SUITE 230
Manufacturer CityCARLSBAD CA 92011
Manufacturer CountryUS
Manufacturer Postal92011
Manufacturer Phone7145157571
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameHYGEIA FLANGE
Generic NameFLANGE
Product CodeHGY
Date Received2015-04-17
Model NumberNA
Catalog NumberNA
Lot NumberNA
ID NumberNA
OperatorLAY USER/PATIENT
Device AvailabilityN
Device AgeNA
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerHYGEIA II MEDICAL GROUP, INC.
Manufacturer Address6005 HIDDEN VALLEY ROAD SUITE 230 CARLSBAD CA 92011 US 92011


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2015-04-17