SUNDASH RADIUS SR -48 *

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2015-04-24 for SUNDASH RADIUS SR -48 * manufactured by *.

Event Text Entries

[5709188] I am a fire investigator. I recently responded to a fire involving a sundash radius st-48. The fire was contained to the electrical cord that connects the main unit to the door. This appears to be a design flaw. The bundle of electrical wires contained in the protective sleeve hid arching wire from immediate observation and detection. This arch heated and eventually flamed up while in use by a customer. The fire was extinguished with a dry chemical extinguisher. The design flaw is the hinge has a sharp bend in the electrical bundle. The more the door is opened and closed the more the potential for the wiring insulation to break down. (b)(6) is the place of business. Place of recreation or sports - (b)(6). Investigators: (b)(6) fire incident # (b)(6). Document number: (b)(4). Report number: (b)(4).
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report NumberMW5042288
MDR Report Key4730457
Date Received2015-04-24
Date of Event2015-03-23
Date Added to Maude2015-04-27
Event Key0
Report Source CodeVoluntary report
Manufacturer LinkN
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag0
Health Professional0
Initial Report to FDA3
Report to FDA3
Event Location0
Single Use0
Previous Use Code0
Event Type3
Type of Report3

Device Details

Brand NameSUNDASH RADIUS SR -48
Generic NameSTAND UP SUN TAN BOOTH
Product CodeLEJ
Date Received2015-04-24
Model Number*
Catalog Number*
Lot Number*
ID Number*
OperatorOTHER
Device Sequence No1
Device Event Key0
Manufacturer*
Manufacturer Address* * *


Patients

Patient NumberTreatmentOutcomeDate
10 2015-04-24

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.