MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 01,05,06 report with the FDA on 2015-04-27 for FREE PSA 03289788190 manufactured by Roche Diagnostics.

Event Text Entries

[5706226] The customer received questionable free psa and total psa total (free + complexed) psa - prostate-specific antigen (total psa) results for one patient sample from cobas e601 analyzer serial number (b)(4). The specific date of testing was not provided. Refer to the medwatch with patient identifier (b)(6) for the total psa assay. The initial results were free psa 8. 72 ng/ml and total psa 0. 82 ng/ml. The repeat results were free psa 8. 72 ng/ml and total psa 0. 815 ng/ml. On 04/15/2015, the service personnel ran the sample a third time and the results were free psa 9. 31 ng/ml and total psa 0. 80 ng/ml. As the customer had another similar case, the customer sent the sample to be tested on an abbott and siemens centaur analyzer. Both of the results were a total psa greater than the free psa result. No specific data was provided. The laboratory's results and the results from the centaur were reported to their customer. Information concerning if the patient was adversely affected was requested, but was not provided. No action was taken based on the customer's results. As the sample could not be provided for further investigation, a specific root cause could not be determined. As the results for both assays were reproducible, interference in the sample was possible. Based on the provided calibration and qc data, a general reagent or system issue was not indicated.
Patient Sequence No: 1, Text Type: D, B5


[13154475] This event occurred in (b)(6). (b)(4).
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number1823260-2015-03308
MDR Report Key4731513
Report Source01,05,06
Date Received2015-04-27
Date of Report2015-04-27
Date of Event2015-04-15
Date Mfgr Received2015-04-16
Date Added to Maude2015-04-27
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location3
Manufacturer ContactNA MICHAEL LESLIE
Manufacturer Street9115 HAGUE ROAD NA
Manufacturer CityINDIANAPOLIS IN 46250
Manufacturer CountryUS
Manufacturer Postal46250
Manufacturer Phone3175214343
Manufacturer G1ROCHE DIAGNOSTICS GMBH
Manufacturer StreetSANDHOFERSTRASSE 116 NA
Manufacturer CityMANNHEIM (BADEN-WURTTEMBERG) 68305
Manufacturer CountryGM
Manufacturer Postal Code68305
Single Use3
Previous Use Code3
Removal Correction NumberNA
Event Type3
Type of Report3

Device Details

Brand NameFREE PSA
Generic NameTEST,PROSTATE SPECIFIC ANTIGEN,FREE,(NONCOMPLEXED) TO DISTINGUISH PROSTATE CA
Product CodeMTG
Date Received2015-04-27
Model NumberNA
Catalog Number03289788190
Lot Number178872
ID NumberNA
Device Expiration Date2015-10-30
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerROCHE DIAGNOSTICS
Manufacturer Address9115 HAGUE ROAD NA INDIANAPOLIS IN 46250 US 46250