WATERPIK WATER FLOSSER WP-100PLT

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 04 report with the FDA on 2015-06-08 for WATERPIK WATER FLOSSER WP-100PLT manufactured by Water Pik, Inc..

Event Text Entries

[5841730] Per the customer.... "used the wp-100plt friday (b)(6) 2015 in the front near the bridge on top of the mouth. The hose split during use, scared her. Took the tip out of mouth and part of bridge or crown came out. Must have happened when the hose broke and maybe banged it into her tooth and broke the bridge or crown. "
Patient Sequence No: 1, Text Type: D, B5


[13346904] Unit in question has not yet been returned for testing and evaluation. Device in question has not been received.
Patient Sequence No: 1, Text Type: N, H10


[24663883] Inspection of returned unit showed that the irrigator hose was broken below the handle. The hose material was brittle and could easily be broken in the area below the handle and involving the first coil of the hose. The remainder of the hose coils were flexible and normal. It appears that the hose material was attached and degraded by a chemical. This may have been a medicament that ran down the handle/hose during use or it may have been due to over spray from a material such as hair spray.
Patient Sequence No: 1, Text Type: N, H10


[24663884] Per the customer.... "used the wp-100plt friday (b)(6) 2015 in the front near the bridge on top of the mouth. The hose split during use, scared her. Took the tip out of mouth and part of bridge or crown came out. Must have happened when the hose broke and maybe banged it into her tooth and broke the bridge or crown. "
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number0001712259-2015-00003
MDR Report Key4825156
Report Source04
Date Received2015-06-08
Date of Report2015-06-30
Date of Event2015-05-18
Date Mfgr Received2015-05-18
Device Manufacturer Date2014-07-17
Date Added to Maude2015-06-08
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA0
Event Location0
Manufacturer ContactMR. ROBERT VANDER VLIET
Manufacturer Street1730 EAST PROSPECT ROAD
Manufacturer CityFORT COLLINS CO 805530001
Manufacturer CountryUS
Manufacturer Postal805530001
Manufacturer G1WATER PIK, INC.
Manufacturer Street1730 EAST PROSPECT ROAD
Manufacturer CityFORT COLLINS CO 80553000
Manufacturer CountryUS
Manufacturer Postal Code80553 0001
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameWATERPIK WATER FLOSSER
Generic NameORAL IRRIGATOR
Product CodeEFS
Date Received2015-06-08
Returned To Mfg2015-06-25
Model NumberWP-100PLT
Lot NumberJX111229A
OperatorLAY USER/PATIENT
Device AvailabilityR
Device AgeDA
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerWATER PIK, INC.
Manufacturer Address1730 EAST PROSPECT ROAD FORT COLLINS CO 80553000 US 80553 0001


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2015-06-08

© 2026 FDA.report