PKG, MEDICAL POWER SUPPLY 0240031004

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2015-07-28 for PKG, MEDICAL POWER SUPPLY 0240031004 manufactured by Stryker Endoscopy-san Jose.

Event Text Entries

[23092806] Additional information will be provided once the investigation has been completed.
Patient Sequence No: 1, Text Type: N, H10


[23092807] It has been reported by the technical services that the product is not working. There was a delay of 30-60 minutes.
Patient Sequence No: 1, Text Type: D, B5


[32347831] The product was returned and the failure mode was confirmed. Visual inspection: no visual damage outside the pkg, medical power supply. Functional inspection : power supply not working was verified using a vision pro monitor. Probable root cause/s could be a bad power supply. The product was returned for investigation and the reported failure mode was confirmed. The failure mode will be monitored for future reoccurrence.
Patient Sequence No: 1, Text Type: N, H10


[32347832] It has been reported by the technical services that the product is not working. Additional information: there was a delay of 30-60 minutes.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number0002936485-2015-00683
MDR Report Key4947943
Date Received2015-07-28
Date of Report2015-07-03
Date of Event2015-06-30
Date Mfgr Received2015-07-03
Date Added to Maude2015-07-28
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMR. KIMBERLY LYNCH
Manufacturer Street5900 OPTICAL COURT
Manufacturer CitySAN JOSE CA 95138
Manufacturer CountryUS
Manufacturer Postal95138
Manufacturer Phone4087542000
Manufacturer G1STRYKER ENDOSCOPY-SAN JOSE
Manufacturer Street5900 OPTICAL COURT
Manufacturer CitySAN JOSE CA 95138
Manufacturer CountryUS
Manufacturer Postal Code95138
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NamePKG, MEDICAL POWER SUPPLY
Generic NameCAMERA, TELEVISION, SURGICAL, WITHOUT AUDIO
Product CodeFWB
Date Received2015-07-28
Returned To Mfg2015-07-30
Catalog Number0240031004
Device AvailabilityR
Device AgeDA
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerSTRYKER ENDOSCOPY-SAN JOSE
Manufacturer Address5900 OPTICAL COURT SAN JOSE CA 95138 US 95138


Patients

Patient NumberTreatmentOutcomeDate
10 2015-07-28

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.