POLIDENT DENTURE ADHESIVE CREAM

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2015-08-04 for POLIDENT DENTURE ADHESIVE CREAM manufactured by Glaxosmithkline Dungarvan Ltd..

Event Text Entries

[23393513] Fu made with the consumer on 15/jul/2015. He used to use the product once a day, but as the weather got warmer, he applied the product twice a day, squeezing small amount of the product. The consumer discontinued the product at the time of follow-up. He had never experienced renal disease before. He was hospitalized on (b)(6) 2015, and admitted for 17 days. At first, he experienced urination difficulty, and visited a hospital and got a blood test. Jaundice was concurrently developed. Liver enzyme level was normal, though. So thus he was hospitalized. First diagnosis result was acute renal failure due to drug intoxication. As the consumer told the doctor the truth that he was using polident denture adhesive cream and his dietary habits and etc, physician diagnosed that the symptom seemed to be related to polident denture adhesive cream. The symptoms were recovering.
Patient Sequence No: 1, Text Type: N, H10


[23393514] Acute renal failure. Difficulty in urination. Jaundice. Drug intoxication. Case description: this case was reported by a consumer via call center representative and described the occurrence of acute renal failure in a male patient who received double salt dental adhesive cream (polident denture adhesive cream) cream for denture wearer. Concurrent medical conditions included acute renal failure. On an unknown date, the patient started polident denture adhesive cream. On an unknown date, an unknown time after starting polident denture adhesive cream, the patient experienced acute renal failure (serious criteria hospitalization and gsk medically significant), urination difficulty, jaundice and drug intoxication. On an unknown date, the outcome of the acute renal failure, urination difficulty, jaundice and drug intoxication were recovering/resolving. The reporter considered the acute renal failure, urination difficulty, jaundice and drug intoxication to be probably related to polident denture adhesive cream. Additional details: concurrent drug: no. Concurrent disease: acute renal failure. Direct contact to hcp: disagree. A male consumer born in (b)(6) had used polident denture adhesive cream for adhesive denture since one year ago, and at the time of initial reporting, he did not discontinue the product. He applied the product twice a day on upper and lower dentures. The consumer said since one year ago, the product was melted and swallowed whenever he used polident denture adhesive cream. There had been no other adverse event while using the product. But on (b)(6) 2015, as he had difficulty in urination, he visited a hospital and was hospitalized for around 16 days. On (b)(6) 2015, via hospital, he heard the symptom was acute renal failure. He was taken a biopsy to figure out the cause of disease. Polident denture adhesive cream was one option of the causes during cause analysis. He visited the hospital at this initial reporting date, and according to the consumer, the physician said recovery speed of the disease was slow, and the reason of slow recovery was polident denture adhesive cream and the physician also regarded polident denture adhesive cream as the cause of disease.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3003721894-2015-00001
MDR Report Key4995093
Date Received2015-08-04
Date of Report2015-07-14
Date Mfgr Received2015-07-14
Date Added to Maude2015-08-12
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional0
Initial Report to FDA0
Report to FDA3
Event Location3
Manufacturer StreetPO BOX 13398
Manufacturer CityRESEARCH TRIANGLE PARK NC 27709
Manufacturer CountryUS
Manufacturer Postal27709
Manufacturer Phone8888255249
Manufacturer G1GSK
Single Use3
Previous Use Code3
Event Type3
Type of Report0

Device Details

Brand NamePOLIDENT DENTURE ADHESIVE CREAM
Generic NameDENTURE ADHESIVE
Product CodeKOL
Date Received2015-08-04
Device Availability*
Device AgeDA
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerGLAXOSMITHKLINE DUNGARVAN LTD.
Manufacturer AddressDUNGARVAN, WATERFORD EI


Patients

Patient NumberTreatmentOutcomeDate
101. Hospitalization; 2. Other 2015-08-04