NUCLEUS 24 AUDITORY BRAINSTEM IMPLANT SYSTEM ABI541

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative report with the FDA on 2015-09-10 for NUCLEUS 24 AUDITORY BRAINSTEM IMPLANT SYSTEM ABI541 manufactured by Cochlear Ltd..

Event Text Entries

[25498669] Implanted device remains.
Patient Sequence No: 1, Text Type: N, H10


[25498670] Per the clinic, the patient experienced intermittencies and subsequent loss of connection to the internal device, however, the issue could not be resolved. The implanted device remains. It is unknown if there are plans to explant the device and reimplant the patient with a new device as of the date of this report.
Patient Sequence No: 1, Text Type: D, B5


[42794514] Per the clinic, the device was explanted on (b)(6) 2016, and the patient was reimplanted with a new device on the contralateral side during the same surgery. Device not returned to manufacturer.
Patient Sequence No: 1, Text Type: N, H10


[47795192] Correction: the device was not explanted as previously reported. The device remains insitu. This report is filed june 21, 2016. Implanted device remains.
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number6000034-2015-01898
MDR Report Key5069689
Report SourceCOMPANY REPRESENTATIVE
Date Received2015-09-10
Date of Report2016-06-03
Date of Event2015-08-25
Date Mfgr Received2016-06-03
Date Added to Maude2015-09-10
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationAUDIOLOGIST
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. BIANCA HANLON
Manufacturer Street1 UNIVERSITY AVENUE
Manufacturer CityMACQUARIE UNIVERSITY, NSW 2109
Manufacturer CountryAS
Manufacturer Postal2109
Manufacturer Phone2 9428 655
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameNUCLEUS 24 AUDITORY BRAINSTEM IMPLANT SYSTEM
Generic NameMHE
Product CodeMHE
Date Received2015-09-10
Model NumberABI541
OperatorLAY USER/PATIENT
Device AvailabilityN
Device AgeDA
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerCOCHLEAR LTD.
Manufacturer Address1 UNIVERSITY AVENUE PO BOX 629 MACQAURIE UNIVERSITY, NSW 2109 AS 2109


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2015-09-10