VIDAS? B?R?A?H?M?S PCT (TM) 30450-01

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2015-10-21 for VIDAS? B?R?A?H?M?S PCT (TM) 30450-01 manufactured by Biomerieux Sa.

Event Text Entries

[29296719] Device not returned to manufacturer.
Patient Sequence No: 1, Text Type: N, H10


[29296720] On (b)(6), 2015 customer called to report an issue related to the negative range (false negative) when using product vidas b? R? A? H? M? S pct (tm) (pct), (b)(4), lot 1004045770. Upon retesting samples results were positive. Test results as follows: initial rfv = -2, result = <0. 05 : repeat rfv = 6, result = 0. 08. Second set of values : initial rfv = -2, result = <0. 05 : repeat rfv = 323, result = 3. 60. Customer reported no patient was harmed or treated incorrectly.
Patient Sequence No: 1, Text Type: D, B5


[30121764] Internal investigation was conducted. The analysis of the vidas? Pct batch 1004045770 indicates no anomalies associated with the number of negative samples tested by the qc laboratory. For the investigation , eleven (11) negative samples were tested using batch 1004045770. Three (3) negative samples were obtained (relative fluorescence values at -1) with no change in interpretation. These negative rfv values near 0 do not indicate a lack of sensitivity. The discrepant results obtained by the customer are not due to negative rfv values. The performance of the batch vidas? Pct 1004045770 is within specifications.
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number3002769706-2015-00124
MDR Report Key5163755
Date Received2015-10-21
Date of Report2015-10-02
Date Mfgr Received2015-10-02
Device Manufacturer Date2015-06-11
Date Added to Maude2015-10-21
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag0
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMR. RYAN LEMELLE
Manufacturer Street595 ANGLUM ROAD
Manufacturer CityHAZELWOOD MO 63042
Manufacturer CountryUS
Manufacturer Postal63042
Manufacturer Phone3147318582
Manufacturer G1BIOMERIEUX SA
Manufacturer StreetCHEMIN DE L ORME
Manufacturer CityMARCY L ETOILE, RHONE 69280
Manufacturer CountryFR
Manufacturer Postal Code69280
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameVIDAS? B?R?A?H?M?S PCT (TM)
Generic NameVIDAS? B?R?A?H?M?S PCT (TM)
Product CodeNTM
Date Received2015-10-21
Catalog Number30450-01
Lot Number1004045770
Device Expiration Date2016-05-17
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device AgeDA
Device Eval'ed by MfgrN
Device Sequence No1
Device Event Key0
ManufacturerBIOMERIEUX SA
Manufacturer AddressCHEMIN DE L ORME MARCY L ETOILE, RHONE 69280 FR 69280


Patients

Patient NumberTreatmentOutcomeDate
10 2015-10-21

© 2026 FDA.report
This site is not affiliated with or endorsed by the FDA.