BIOSHIELD IRRIGATOR 00711133

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2016-02-19 for BIOSHIELD IRRIGATOR 00711133 manufactured by United States Endoscopy Group, Inc..

Event Text Entries

[39205497] The bioshield biopsy valve is used to cover the opening to the biopsy/suction channel inlet of a gastrointestinal endoscope. The bioshield biopsy valve provides access for endoscopic device passage and exchange, helps maintain insufflation and minimizes leakage of biomaterial from the biopsy port throughout the gastrointestinal endoscopic procedure. The bioshield irrigator will also allow for remote irrigation via an attached irrigation line. Us endoscopy received a report from a (b)(4), that a bioshield leaked a lot of water. The leaking occurred during insufflation with an irrigation pump. The staff was wearing appropriate personal protective equipment (ppe). There was no reported harm to the patient or user. The device was not returned to for analysis. Review of the device history record (dhr) found no manufacturing or quality problems and all inspections were completed with acceptable results documented. The instructions for use (ifu) provides the following regarding leaks: irrigating through the bioshield biopsy valve's irrigation line with a device in the biopsy channel requires sufficient space between the diameter of the device and the diameter of the endoscope's channel. Adequate space is required to allow fluid to pass freely at a moderate pressure so that the valve connections do not leak. Example: 2. 3mm device in a 2. 8mm channel (space. 5mm) = inadequate space to allow for moderate pressure delivery of fluids; leakage may occur. Example: 2. 3mm device in a 3. 2mm channel (space. 9mm) = space is increased, keeping pressure in the moderate range, thus limiting the potential for valve connection leakage. For part #00711133 and #00711137: leakage through non-sheathed spring-coiled devices such as biopsy forceps will occur if irrigation is performed while the non-sheathed device remains in the biopsy channel. Do not leave a device hanging from the valve. Doing so can cause the creation of a larger valve slit/hole that may cause leakage. If the lid of the valve is opened while attached to the endoscope during a procedure, scope suction will be compromised and leakage may occur. If leakage occurs, a sterile gauze should be used to cover the valve. Device not returned.
Patient Sequence No: 1, Text Type: N, H10


[39205498] The bioshield biopsy valve is used to cover the opening to the biopsy/suction channel inlet of a gastrointestinal endoscope. The bioshield biopsy valve provides access for endoscopic device passage and exchange, helps maintain insufflation and minimizes leakage of biomaterial from the biopsy port throughout the gastrointestinal endoscopic procedure. The bioshield irrigator will also allow for remote irrigation via an attached irrigation line. Us endoscopy received a report from a distributor in (b)(4), that a bioshield leaked a lot of water. The leaking occurred during insufflation with an irrigation pump. The staff was wearing appropriate personal protective equipment (ppe). There was no reported harm to the patient or user.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1528319-2016-00005
MDR Report Key5448361
Date Received2016-02-19
Date of Report2016-02-19
Date of Event2016-01-21
Date Mfgr Received2016-01-22
Device Manufacturer Date2015-11-08
Date Added to Maude2016-02-19
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMRS COLETTA COHARA
Manufacturer Street5976 HEISLEY ROAD
Manufacturer CityMENTOR OH 44060
Manufacturer CountryUS
Manufacturer Postal44060
Manufacturer Phone4403586251
Manufacturer G1UNITED STATES ENDOSCOPY GROUP, INC.
Manufacturer Street5976 HEISLEY RD
Manufacturer CityMENTOR OH 44060
Manufacturer CountryUS
Manufacturer Postal Code44060
Single Use3
Previous Use Code3
Event Type3
Type of Report0

Device Details

Brand NameBIOSHIELD IRRIGATOR
Generic NameBIOPSY VALVE
Product CodeODD
Date Received2016-02-19
Model Number00711133
Catalog Number00711133
Lot Number1518154
Device Expiration Date2018-11-30
OperatorPHYSICIAN
Device AvailabilityN
Device Eval'ed by MfgrN
Device Sequence No1
Device Event Key0
ManufacturerUNITED STATES ENDOSCOPY GROUP, INC.
Manufacturer Address5976 HEISLEY RD MENTOR OH 44060 US 44060


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2016-02-19