MERGE EYE STATION MERGE EYE STATION V11.1

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2016-02-25 for MERGE EYE STATION MERGE EYE STATION V11.1 manufactured by Merge Healthcare.

Event Text Entries

[39468337] Merge healthcare manufactures merge eye station software to be used on workstations manufactured by (b)(4). Merge has notified (b)(4) of the issue caused by their field technician. Investigation into the details of patient data loss per (b)(4): customer allegation: 2 drive raid - cannot boot. Returned product evaluation: both drives were inaccessible- even the original "good" one. Could not recover any data. Resolution: replaced both drives and reloaded win 7 and eyestation 11. 1 sw. -returned to customer.
Patient Sequence No: 1, Text Type: N, H10


[39468338] Merge eye station is a comprehensive software platform for the import, integration and review of patient data and clinical information in an eye care environment. Merge eye station allows for the capture, collection, management, enhancement and review of the patient demographics, image data, diagnostic data and clinical reports from a variety of medical devices through either a direct connection with the instruments or through computerized networks. Customer reported a drive failure on a two disk mirrored raid, also known as a raid 1, on a windows 7 workstation installed with merge eye station. A raid 1 consists of an exact copy, or mirror, of a set of data on two or more disks. Typically a raid 1 mirrored pair contains two disks. When the primary drive failed, the workstation continued functioning with the backup, mirrored drive as expected. Merge support worked with the hardware manufacturer of the pc, (b)(4), to have a technician from (b)(4) go onsite to replace the failed drive. It was expected of (b)(4) to insert a blank drive into the workstation so the mirror would rebuild and the workstation would function as it did prior to the primary hard drive failure. On (b)(6) 2016, the (b)(4) technician arrived onsite and inserted a windows 7 hard drive into the workstation, however, the drive should not have had an operating system installed on it as the workstation was configured with a mirrored raid. Once the new primary hard drive was installed with the windows 7 operating system, the raid was rebuilt and the primary disk overrode what was on the mirrored hard drive, erasing the merge eye station application, including patient data and images. This loss of patient data has a potential to cause a delay in diagnosis or treatment. (b)(4).
Patient Sequence No: 1, Text Type: D, B5


[43623116] Merge healthcare manufactures merge eye station software to be used on workstations manufactured by (b)(4). Merge has notified (b)(4) of the issue caused by their field technician. Investigation into the details of patient data loss per (b)(4): customer allegation: 2 drive raid - cannot boot. Returned product evaluation: both drives were inaccessible- even the original "good" one. Could not recover any data. Resolution: replaced both drives and reloaded (b)(4) and eyestation (b)(4). -returned to customer. Further investigation was performed and it was found that the images for one patient was lost and that exam contained 36 images. There were no patients/exams that needed to be rescheduled because of this event.
Patient Sequence No: 1, Text Type: N, H10


[43623117] Merge eye station is a comprehensive software platform for the import, integration and review of patient data and clinical information in an eye care environment. Merge eye station allows for the capture, collection, management, enhancement and review of the patient demographics, image data, diagnostic data and clinical reports from a variety of medical devices through either a direct connection with the instruments or through computerized networks. Customer reported a drive failure on a two disk mirrored raid, also known as a raid 1, on a windows 7 workstation installed with merge eye station. A raid 1 consists of an exact copy, or mirror, of a set of data on two or more disks. Typically a raid 1 mirrored pair contains two disks. When the primary drive failed, the workstation continued functioning with the backup, mirrored drive as expected. Merge support worked with the hardware manufacturer of the pc, (b)(4), to have a technician from (b)(4) go onsite to replace the failed drive. It was expected of (b)(4) to insert a blank drive into the workstation so the mirror would rebuild and the workstation would function as it did prior to the primary hard drive failure. On 1/29/2016, the (b)(4) technician arrived onsite and inserted a (b)(4) hard drive into the workstation, however, the drive should not have had an operating system installed on it as the workstation was configured with a mirrored raid. Once the new primary hard drive was installed with the (b)(4) operating system, the raid was rebuilt and the primary disk overrode what was on the mirrored hard drive, erasing the merge eye station application, including patient data and images. This loss of patient data has a potential to cause a delay in diagnosis or treatment. (b)(4).
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2183926-2016-00450
MDR Report Key5461835
Date Received2016-02-25
Date of Report2016-03-14
Date of Event2016-01-26
Date Mfgr Received2016-01-26
Device Manufacturer Date2012-12-04
Date Added to Maude2016-02-25
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. MEG MUCHA
Manufacturer Street900 WALNUT RIDGE DR
Manufacturer CityHARTLAND WI 53029
Manufacturer CountryUS
Manufacturer Postal53029
Manufacturer Phone2629123514
Manufacturer G1MERGE HEALTHCARE
Manufacturer Street900 WALNUT RIDGE DRIVE
Manufacturer CityHARTLAND WI 53029
Manufacturer CountryUS
Manufacturer Postal Code53029
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameMERGE EYE STATION
Generic NamePICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
Product CodeNFJ
Date Received2016-02-25
Model NumberMERGE EYE STATION V11.1
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device Age3 YR
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerMERGE HEALTHCARE
Manufacturer Address900 WALNUT RIDGE DRIVE HARTLAND WI 53029 US 53029