VERION DIGITAL MARKER M X-SPM 8065998243

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a foreign,health professional report with the FDA on 2016-03-31 for VERION DIGITAL MARKER M X-SPM 8065998243 manufactured by Wavelight Gmbh (agps).

Event Text Entries

[41522096] Sample was not returned. No information about the device or serial number was provided. No contact information provided; therefore, unable to obtain further follow up information. No technical root cause could be determined, based on the information provided. (b)(4).
Patient Sequence No: 1, Text Type: N, H10


[41522097] An ophthalmologist reported an intraocular lens (iol) axis was incorrectly aligned on an eye. Reporter indicated a secondary procedure was performed to relocate the iol to the correct axis. Additional information is unavailable.
Patient Sequence No: 1, Text Type: D, B5


[48107940] No information about the reported device was provided. No technical root cause could be determined, based on the information provided. Generally, an unstable overlay can be seen if illumination is too dark or microscope zoom level not appropriate during surgery. In such an event the surgeon would not be able to accurately see to align the lens. (b)(4).
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number3010300699-2016-00014
MDR Report Key5537484
Report SourceFOREIGN,HEALTH PROFESSIONAL
Date Received2016-03-31
Date of Report2016-06-23
Date Mfgr Received2016-05-30
Date Added to Maude2016-03-31
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMR. EDDIE DARTON, MD, JD
Manufacturer StreetAM WOLFSMANTEL 5
Manufacturer CityERLANGEN 91058
Manufacturer CountryGM
Manufacturer Postal91058
Manufacturer Phone8175686660
Manufacturer G1WAVELIGHT GMBH (AGPS)
Manufacturer StreetRHEINSTRASSE 8
Manufacturer CityTELOW BERLIN 14513
Manufacturer CountryGM
Manufacturer Postal Code14513
Single Use3
Remedial ActionOT
Previous Use Code3
Removal Correction NumberNA
Event Type3
Type of Report3

Device Details

Brand NameVERION DIGITAL MARKER M
Generic NameMARKER, OCULAR
Product CodeFTH
Date Received2016-03-31
Model NumberX-SPM
Catalog Number8065998243
Lot NumberASKU
ID NumberASKU
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device AgeDA
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerWAVELIGHT GMBH (AGPS)
Manufacturer AddressRHEINSTRASSE 8 TELTOW 14513 GM 14513


Patients

Patient NumberTreatmentOutcomeDate
101. Other; 2. Required No Informationntervention 2016-03-31