PROGRAMMING SOFTWARE MODEL 250 NA

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2016-05-19 for PROGRAMMING SOFTWARE MODEL 250 NA manufactured by Cyberonics - Houston.

Event Text Entries

[46672345] (b)(4).
Patient Sequence No: 1, Text Type: N, H10


[46672346] A field representative reported that when attempting to interrogate two demo devices an error message was appearing on his tablet programmer. The programming wand battery status was checked and found to be adequate. The user later attempted a different programming wand with the same usb cable and was still unable to interrogate his demo generators. Upon using a replacement usb cable the tablet programming system functioned properly. The suspect usb cables was returned for product analysis. Analysis confirmed a disconnected wire on the usb serial cable printed circuit board (pcb). Once the wire was soldered onto the serial cable pcb no further anomalies were identified and the cable functioned normally.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1644487-2016-01069
MDR Report Key5667163
Date Received2016-05-19
Date of Report2016-05-04
Date of Event2016-05-04
Date Mfgr Received2016-05-04
Device Manufacturer Date2015-05-14
Date Added to Maude2016-05-19
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMRS. NJEMILE CRAWLEY
Manufacturer Street100 CYBERONICS BLVD SUITE 600
Manufacturer CityHOUSTON TX 77058
Manufacturer CountryUS
Manufacturer Postal77058
Manufacturer Phone2812287200
Manufacturer G1CYBERONICS - HOUSTON
Manufacturer Street100 CYBERONICS BLVD SUITE 600
Manufacturer CityHOUSTON TX 77058
Manufacturer CountryUS
Manufacturer Postal Code77058
Single Use3
Previous Use Code3
Removal Correction NumberNA
Event Type3
Type of Report0

Device Details

Brand NamePROGRAMMING SOFTWARE
Generic NamePROGRAMMING COMPUTER
Product CodeLJY
Date Received2016-05-19
Returned To Mfg2016-05-10
Model NumberMODEL 250
Catalog NumberNA
Lot NumberNA
ID NumberVERSION 11.0
Device AvailabilityR
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerCYBERONICS - HOUSTON
Manufacturer Address100 CYBERONICS BLVD NA HOUSTON TX 77058 US 77058


Patients

Patient NumberTreatmentOutcomeDate
10 2016-05-19