CLINIMACS PLUS INSTRUMENT N/A 151-01

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,health report with the FDA on 2016-05-23 for CLINIMACS PLUS INSTRUMENT N/A 151-01 manufactured by Miltenyi Biotec Gmbh.

Event Text Entries

[45688897] Device not returned to the manufacturer.
Patient Sequence No: 1, Text Type: N, H10


[45688898] Approx. 20 min into the program, the instrument displayed an error. "pump error: pump door open" even though the operator did not adjust the clinimacs plus instrument, the pump door was close and tubing was threaded properly. The program gave the operator approx. 300 sec to response the issue. After 300 sec, the run was automatically aborted by the clinimacs plus instrument. An emergency elution was performed. The unprocessed product volume was transferred to the recovered elution and a second run was performed with a new kit. Therefore, the cellular material could be rescued and any risk for the patient could be ruled out.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3005290010-2016-00070
MDR Report Key5671282
Report SourceCOMPANY REPRESENTATIVE,HEALTH
Date Received2016-05-23
Date of Report2016-05-20
Date of Event2016-04-21
Date Mfgr Received2016-04-06
Device Manufacturer Date2015-12-21
Date Added to Maude2016-05-23
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationOTHER HEALTH CARE PROFESSIONAL
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS NANCY JOHANSEN
Manufacturer Street85 HAMILTON ST
Manufacturer CityCAMBRIDGE MA 02139
Manufacturer CountryUS
Manufacturer Postal02139
Manufacturer Phone6172180062
Manufacturer G1MILTENYI BIOTEC GMBH
Manufacturer StreetFRIEDRICH-EBERT-STRASSE 68
Manufacturer CityBERGISCH GLADBACH, 51429
Manufacturer CountryGM
Manufacturer Postal Code51429
Single Use3
Remedial ActionOT
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameCLINIMACS PLUS INSTRUMENT
Generic NameICLINIMACS PLUS INSTRUMENT
Product CodeOVG
Date Received2016-05-23
Model NumberN/A
Catalog Number151-01
Lot NumberNOT KNOWN
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerMILTENYI BIOTEC GMBH
Manufacturer AddressFRIEDRICH-EBERT-STRASSE 68 BERGISCH GLADBACH, 51429 GM 51429