POWERORDERS - NOT A MEDICAL DEVICE 2012.01 - 2015.01 N/A

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative report with the FDA on 2016-12-12 for POWERORDERS - NOT A MEDICAL DEVICE 2012.01 - 2015.01 N/A manufactured by Cerner Corporation.

Event Text Entries

[62386231] Cerner distributed a priority review flash notification (flash16-0659-0) on december 5, 2016 to all potentially impacted client sites. The software notification includes a description of the issue, an alternative workflow and notification that a software modification is being developed to address the issue for all sites that could be potentially impacted. Cerner corporation will provide a follow-up report when the software modification is available.
Patient Sequence No: 1, Text Type: N, H10


[62386232] This report documents information related to an issue identified with functionality included in cerner's millennium powerorders. The issue occurs in powerorders when the user adds and signs more than one electronic prescription orderable item and one of the orderable items contains an invalid character outside of the ascii 32-126 characters in the special instructions. This will result in those special instructions to be applied to all orderable items.? This issue could result in a patient taking prescribed medications in a manner other than what the prescriber intended and could lead to negative patient reactions. Cerner has not received communication on any adverse patient events as a result of this issue.
Patient Sequence No: 1, Text Type: D, B5


[74617919] Cerner distributed a priority review flash notification (flash16-0659-0) on december 6, 2016 to all potentially impacted client sites. The software notification included a description of the issue, an alternative workflow and notification that a software modification was developed to address the issue for all sites that could be potentially impacted. Cerner distributed an updated priority review flash notification (flash16-0659-0) on april 19, 2017 to all potentially impacted client sites. The software notification includes a description of the issue, an alternative to prevent the issue from occurring, and notification that a software modification has been developed and is available to address the issue for all sites that could be potentially impacted. Cerner corporation considers the issue resolved and no further narrative is required for follow-up.
Patient Sequence No: 1, Text Type: N, H10


[74617920] The software product mentioned in this medwatch report may not be, by definition, a medical device; however, cerner has chosen to file this medwatch report in order to voluntarily notify the fda of a malfunction associated with this software product. This report documents information related to an issue identified with functionality included in cerner's millennium powerorders. The issue occurs in powerorders when the user adds and signs more than one electronic prescription orderable item and one of the orderable items contains an invalid character outside of the ascii 32-126 characters in the special instructions. This will result in those special instructions to be applied to all orderable items. This issue could result in a patient taking prescribed medications in a manner other than what the prescriber intended and could lead to negative patient reactions. Cerner has not received communication on any adverse patient events as a result of this issue.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1931259-2016-00013
MDR Report Key6165849
Report SourceCOMPANY REPRESENTATIVE
Date Received2016-12-12
Date of Report2017-04-20
Date of Event2016-07-28
Date Mfgr Received2016-07-28
Device Manufacturer Date2015-04-01
Date Added to Maude2016-12-12
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. SHELLEY LOOBY
Manufacturer Street2800 ROCKCREEK PARKWAY
Manufacturer CityKANSAS CITY MO 64117
Manufacturer CountryUS
Manufacturer Postal64117
Manufacturer Phone8162011386
Manufacturer G1CERNER CORPORATION
Manufacturer Street2800 ROCKCREEK PARKWAY
Manufacturer CityKANSAS CITY MO 64117
Manufacturer CountryUS
Manufacturer Postal Code64117
Single Use3
Remedial ActionNO
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NamePOWERORDERS - NOT A MEDICAL DEVICE
Generic NameSOFTWARE
Product CodeLNX
Date Received2016-12-12
Model Number2012.01 - 2015.01
Catalog NumberN/A
Lot NumberN/A
OperatorHEALTH PROFESSIONAL
Device AvailabilityY
Device AgeDA
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerCERNER CORPORATION
Manufacturer Address2800 ROCKCREEK PARKWAY KANSAS CITY MO 64117 US 64117


Patients

Patient NumberTreatmentOutcomeDate
10 2016-12-12

© 2024 FDA.report