DISPOSABLE POLYMER IRRIGATION AND SILICONE IRRIGATION AND ASPIRATION TIPS 8065751511

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2016-12-12 for DISPOSABLE POLYMER IRRIGATION AND SILICONE IRRIGATION AND ASPIRATION TIPS 8065751511 manufactured by Alcon Research, Ltd. - Alcon Precision Device.

Event Text Entries

[62391835] Investigation including root cause analysis is in progress. A supplemental mdr will be filed as necessary in accordance with 21 cfr 803. 56 when additional reportable information becomes available. (b)(4).
Patient Sequence No: 1, Text Type: N, H10


[62391836] A nurse reported that an irrigation / aspiration (i/a) cannula split into two parts during a surgery. The cannula was exchanged to complete the case. There was no patient harm.
Patient Sequence No: 1, Text Type: D, B5


[68135941] Additional information provided in model #/lot #, device available for evaluation? , and concomitant medical products. (b)(4).
Patient Sequence No: 1, Text Type: N, H10


[71380604] (b)(4).
Patient Sequence No: 1, Text Type: N, H10


[71380605] New information received from the customer stating the suspect product is not an irrigation / aspiration tip which was originally reported. It is a phacoemulsification tip.
Patient Sequence No: 1, Text Type: D, B5


[73013525] One balance phaco tip was returned for evaluation for the report of a split cannula into two parts. No lot number was identified with this complaint; therefore, a lot history review could not be conducted. A visual inspection of the phaco tip received was performed and deemed nonconforming. The tip is broken along the cannula. The break extends from the back of the cannula up to the bend region. The wall thickness at the break area is uneven, causing a thin wall. The complaint does confirm the phaco tip is broken. The reason for the breakage is due to a nonconforming thin wall present at the break area. This thin wall is a manufacturing issue created at the machining process for the phaco tip. (b)(4).
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number2523835-2016-00916
MDR Report Key6166456
Date Received2016-12-12
Date of Report2017-04-06
Date of Event2016-11-10
Date Mfgr Received2017-04-05
Date Added to Maude2016-12-12
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. RITA LOPEZ
Manufacturer Street6201 SOUTH FREEWAY MAIL STOP AB2-6
Manufacturer CityFORT WORTH TX 76134
Manufacturer CountryUS
Manufacturer Postal76134
Manufacturer Phone8175514846
Manufacturer G1ALCON RESEARCH, LTD. - HOUSTON
Manufacturer Street9965 BUFFALO SPEEDWAY
Manufacturer CityHOUSTON TX 77054
Manufacturer CountryUS
Manufacturer Postal Code77054
Single Use3
Previous Use Code3
Removal Correction NumberNA
Event Type3
Type of Report3

Device Details

Brand NameDISPOSABLE POLYMER IRRIGATION AND SILICONE IRRIGATION AND ASPIRATION TIPS
Generic NameDEVICE, IRRIGATION, OCULAR SURGERY
Product CodeKYG
Date Received2016-12-12
Returned To Mfg2016-12-22
Model NumberNA
Catalog Number8065751511
Lot NumberUNK
OperatorHEALTH PROFESSIONAL
Device AvailabilityR
Device AgeDA
Device Eval'ed by MfgrY
Device Sequence No1
Device Event Key0
ManufacturerALCON RESEARCH, LTD. - ALCON PRECISION DEVICE
Manufacturer Address714 COLUMBIA AVENUE SINKING SPRING PA 19608 US 19608


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2016-12-12