Patient Sequence No: 1, Text Type: N, H10


[66059725] Transplant administration received an email from an organ procurement organization (opo) on. Preservation solution called static preservation solution -1 (sps-1), manufactured by organ recovery systems. The recall was due to a report by another opo regarding bacterial contamination. According to the report the solution samples obtained from several opened bags were positive for pantoea agglomerans and enterococcus casseliflavus. This microbial growth was reported for two lots of the preservation solution sps-1. Our recipient received a liver and kidney perfused in this solution (lot number pbr-0060-392). The operating room was notified and conducted two separate searches of their inventory, only one bag was found and was removed from the inventory. The pharmacy reported that staff checked the store rooms and did not find any preservation solutions in the two lots cited. The liver service infectious disease physician consulted on the patient and reported that the patient showed no signs or symptom of this infection, patient is stable, afebrile and is 72 days post-transplant currently being treated for a uti. The id consult also stated that the patient has received adequate antibiotic prophylaxis.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number6285496
MDR Report Key6285496
Date Received2017-01-30
Date of Report2017-01-27
Date of Event2016-10-08
Report Date2017-01-27
Date Reported to FDA2017-01-27
Date Reported to Mfgr2017-01-27
Date Added to Maude2017-01-30
Event Key0
Report Source CodeUser Facility report
Manufacturer LinkN
Number of Patients in Event0
Adverse Event Flag0
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameSPS-1
Generic NameORGAN PRESERVATION SOLUTION
Product CodeKDL
Date Received2017-01-30
Lot NumberPBR-0060-392
Device Expiration Date2018-06-01
OperatorPHYSICIAN
Device Availability*
Device Age1 DY
Device Eval'ed by Mfgr*
Device Sequence No1
Device Event Key0
ManufacturerORGAN RECOVERY SYSTEMS, INC.
Manufacturer AddressONE PIERCE PLACE SUITE 475W ITASCA IL 60143 US 60143


Patients

Patient NumberTreatmentOutcomeDate
10 2017-01-30