NVISIONVLE MARKING PROBE 95301-M-20

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative report with the FDA on 2017-02-14 for NVISIONVLE MARKING PROBE 95301-M-20 manufactured by Ninepoint Medical, Inc..

Event Text Entries

[67374585] Device not returned to manufacturer.
Patient Sequence No: 1, Text Type: N, H10


[67374586] An nvisionvle marking probe (20mm) was placed through the endoscope into the stomach. During the procedure the balloon was not inflating as quickly as expected, therefore a decision was made to use a new marking probe. The procedure was aborted, and the remaining air was suctioned to deflate the balloon, however the physician prematurely pulled the marking probe back through the endoscope and the balloon detached from the marking probe and lodged in the endoscope channel. The physician decided to advance the scope into the stomach and push the balloon from the endoscope channel using biopsy forceps into the stomach. A snare was used to obtain the balloon from the stomach. The patient was un-harmed, and case completed using the new marking probe.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3008805841-2017-00001
MDR Report Key6329110
Report SourceCOMPANY REPRESENTATIVE
Date Received2017-02-14
Date of Report2017-02-14
Date of Event2017-01-17
Date Mfgr Received2017-01-17
Device Manufacturer Date2016-11-08
Date Added to Maude2017-02-14
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. HEATHER REED
Manufacturer Street12 OAK PARK DRIVE
Manufacturer CityBEDFORD MA 01730
Manufacturer CountryUS
Manufacturer Postal01730
Manufacturer Phone6172507141
Manufacturer G1NINEPOINT MEDICAL, INC.
Manufacturer Street12 OAK PARK DRIVE
Manufacturer CityBEDFORD MA 01730
Manufacturer CountryUS
Manufacturer Postal Code01730
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameNVISIONVLE MARKING PROBE
Generic NameNVISIONVLE MARKING PROBE
Product CodeNQQ
Date Received2017-02-14
Model Number95301-M-20
Catalog Number95301-M-20
Lot Number004904
Device Expiration Date2017-09-30
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerNINEPOINT MEDICAL, INC.
Manufacturer Address12 OAK PARK DRIVE BEDFORD MA 01730 US 01730


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2017-02-14

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.