FISHERBRAND? LATEX-FREE COHESIVE FLEXIBLE BANDAGES N/A 22363114

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2017-05-03 for FISHERBRAND? LATEX-FREE COHESIVE FLEXIBLE BANDAGES N/A 22363114 manufactured by Suzhou Medsport Products Co., Ltd.

Event Text Entries

[74357788] The customer reported a complaint pertaining to the fisher catalog number 22363114, fisherbrand? Latex-free cohesive flexible bandages. The customer reported that the product was wrapped around the patient's arm after the patient went for a lab draw. At some point after the bandage was wrapped around the patient's arm, the product rolled up and restricted blood flow to the patient's arm. It was communicated the potential exists that the bandage could not be directly seen because it was covered by the patient's gown. The patient developed hemorrhage and had the diagnosis of compartment syndrome in the right forearm intramuscular hematoma. The customer reported that the patient was taking a blood thinning medication, and the patient had to go to surgery for a fasciotomy, followed by another surgery for a secondary closure. The customer stated that the standard of care for patients on anticoagulant is to apply pressure and not to wrap a patient's arm with a bandage. In this case, the customer did not follow the established standard of care for this patient.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number2517925-2017-00001
MDR Report Key6541716
Date Received2017-05-03
Date of Report2017-05-03
Date Facility Aware2017-04-04
Report Date2017-05-03
Date Reported to FDA2017-05-03
Date Reported to Mfgr2017-05-03
Date Added to Maude2017-05-03
Event Key0
Report Source CodeDistributor report
Manufacturer LinkN
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameFISHERBRAND? LATEX-FREE COHESIVE FLEXIBLE BANDAGES
Generic NameELASTIC BANDAGE
Product CodeFQM
Date Received2017-05-03
Model NumberN/A
Catalog Number22363114
Lot NumberUNKNOWN
Device AvailabilityN
Device Eval'ed by Mfgr*
Device Sequence No1
Device Event Key0
ManufacturerSUZHOU MEDSPORT PRODUCTS CO., LTD
Manufacturer AddressNO. 128 FANGZHOU ROAD SUZHOU INDUSTRIAL PARK, SUZHOU, CHINA 215123 CH 215123


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2017-05-03