SAVARIA OMEGA

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a foreign report with the FDA on 2017-05-09 for SAVARIA OMEGA manufactured by Savaria Concord Lifts Inc.

Event Text Entries

[74740493] Total units effected in the united states = (b)(4). As of reporting april 1 2016 - (b)(4) units remain not corrected. The following dates are contacts with dealers by phone and/or email to enforce the requirement to correct the welded part. Initial parts order and shipment date: 02/18/2014. Follow up for work completion date: april 2014, july 2014 , december 2014, february 2015, april 2015 - dealers requesting new kits were sent: august 2015, december 2015, february 2016, march 2016.
Patient Sequence No: 1, Text Type: N, H10


[74740494] During normal operation, the lift while carrying a passenger and wheelchair in the down direction came unfastened from the upper lifting trolley and lifting cable. The carriage and platform now released from the cable system slid down the length of stairs being guided by the lower trolley that remained connected. The platform hit the bottom landing causing the rider to be thrown forward hitting their head against the wall. It was found that the 5 bolts that were holding the carriage to the upper trolley worked loose and eventually failed releasing the platform.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3005753836-2016-00003
MDR Report Key6554078
Report SourceFOREIGN
Date Received2017-05-09
Date of Report2016-04-04
Date of Event2014-02-07
Report Date2014-02-07
Date Reported to Mfgr2014-02-07
Device Manufacturer Date2013-01-15
Date Added to Maude2017-05-09
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Reporter OccupationMEDICAL EQUIPMENT COMPANY TECHNICIAN/REPRESENTATIVE
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMR. WILLIAM RICHARDSON
Manufacturer Street2 WALKER DRIVE
Manufacturer CityBRAMPTON, ONTARIO L6T5E1
Manufacturer CountryCA
Manufacturer PostalL6T5E1
Manufacturer Phone7995555
Manufacturer G1SAVARIA CONCORD LIFTS INC
Manufacturer Street2 WALKER DRIVE
Manufacturer CityBRAMPTON, ONTARIO L6T5E1
Manufacturer CountryCA
Manufacturer Postal CodeL6T5E1
Single Use3
Remedial ActionRP
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameSAVARIA
Generic NameINCLINE PLATFORM LIFT
Product CodePCE
Date Received2017-05-09
Model NumberOMEGA
OperatorLAY USER/PATIENT
Device AvailabilityY
Device Age1 YR
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerSAVARIA CONCORD LIFTS INC
Manufacturer Address2 WALKER DRIVE BRAMPTON, ONTARIO L6T5E1 CA L6T5E1


Patients

Patient NumberTreatmentOutcomeDate
101. Hospitalization 2017-05-09