NGENUITY DIGITAL VISUALIZATION SYSTEM 8065830001

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a company representative,health report with the FDA on 2017-05-16 for NGENUITY DIGITAL VISUALIZATION SYSTEM 8065830001 manufactured by Alcon Research, Ltd. - Irvine Technology Center.

Event Text Entries

[75260157] Investigation including root cause analysis is in progress. A supplemental mdr will be filed as necessary in accordance with 21 cfr 803. 56 when additional reportable information becomes available. (b)(4).
Patient Sequence No: 1, Text Type: N, H10


[75260158] A surgeon reported that a patient complained of diminished vision after a membrane peel procedure. Additional information has been requested but none has been received. This is the second of two reports for this facility.
Patient Sequence No: 1, Text Type: D, B5


[78302297] The clinical analyst reviewed tis file and stated the following:? The customer reported? Diminished vision.? Additional information received from the surgeon indicated it was too early to tell if the event is actually a complication from surgery. No further information has been received. Indocyanine green (icg) selectively stains the internal limiting membrane (ilm) of the retina, and helps to visualize and remove the membrane from the retina. Toxicity and damage to the retina has been reported in studies following macular surgery. Toxic effects can occur to retinal glial cells, to the nerve fiber layer, to retinal ganglion cells, and to the optic nerve. In case of subretinal application, the retinal pigment epithelium can be affected. The mechanisms of toxicity are unclear. Whether the dye itself or some preparations only are causing harm to the retina is subject of an ongoing debate. Icg changes the light absorption properties of the ilm and enhances the stiffness of the membrane, probably by crosslinking of collagen fibers. This effect is responsible for the ease of membrane removal compared to unaided ilm peeling with better visualization. Whether a phototoxic effect plays a clinically significant role in macular surgery has neither been proven nor ruled out yet. Icg at concentrations higher than 1. 25% or application of the dye in air are very likely causing retinal damage. In addition, lower concentrations also carry the risk of iatrogenic damage, depending on the final concentration of potentially toxic substances at the vitreomacular interface and on other mechanisms. Modifications in technique have primarily focused on efforts to reduce the potential toxicity of icg. These modifications have included variations in the icg concentration, limiting the staining time, and reduction of light intensity and exposure time. Protecting the hole with a viscoelastic substance to keep the bare retinal pigment epithelium from being exposed to the icg solution also has been reported. The exact mechanism for the potential toxicity is not known. Possible mechanisms include a direct toxic effect of icg to the retinal pigment epithelium (rpe) cells and/or retina. In vitro studies have shown that exposure of icg to cultured human rpe cells results in dose and time dependent damage to cellular structure. Also, it has been shown that icg exposure results in alterations in cellular function in human rpe cell cultures. Another potential mechanism is enhanced phototoxicity. Although the use of icg improves visualization of the ilm and should reduce surgical time and time of light exposure, icg may reduce the "safe time" for light exposure, and therefore increase the potential for light toxicity. ? Product evaluation no further information was able to be obtained from this customer. With no additional, related information provided, the customers reported event was not able to be confirmed. The root cause cannot be determined conclusively. (b)(4).
Patient Sequence No: 1, Text Type: N, H10


MAUDE Entry Details

Report Number2028159-2017-02012
MDR Report Key6569268
Report SourceCOMPANY REPRESENTATIVE,HEALTH
Date Received2017-05-16
Date of Report2017-06-20
Date of Event2017-05-10
Date Mfgr Received2017-06-16
Date Added to Maude2017-05-16
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. NADIA BAILEY
Manufacturer Street6201 SOUTH FREEWAY MAIL STOP AB2-6
Manufacturer CityFORT WORTH TX 76134
Manufacturer CountryUS
Manufacturer Postal76134
Manufacturer Phone8176152230
Manufacturer G1ALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER
Manufacturer Street15800 ALTON PARKWAY
Manufacturer CityIRVINE CA 92618
Manufacturer CountryUS
Manufacturer Postal Code92618
Single Use3
Previous Use Code3
Removal Correction NumberNA
Event Type3
Type of Report3

Device Details

Brand NameNGENUITY DIGITAL VISUALIZATION SYSTEM
Generic NameMICROSCOPE, OPERATING & ACC., AC-POWERED, OPHTHALMIC
Product CodeEPT
Date Received2017-05-16
Model NumberNA
Catalog Number8065830001
Lot NumberASKU
ID NumberASKU
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device AgeDA
Device Eval'ed by Mfgr*
Device Sequence No1
Device Event Key0
ManufacturerALCON RESEARCH, LTD. - IRVINE TECHNOLOGY CENTER
Manufacturer Address15800 ALTON PARKWAY IRVINE CA 92618 US 92618


Patients

Patient NumberTreatmentOutcomeDate
101. Other 2017-05-16

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.