ONE TRAY

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2017-05-25 for ONE TRAY manufactured by Innovative Sterilization Technologies Llc.

Event Text Entries

[75941270] This device is available for return. A follow up mdr will be submitted upon completion of the device investigation.
Patient Sequence No: 1, Text Type: N, H10


[75941271] We have recently obtained one tray to use in our immediate use steam sterilizer. This is used to get quicker access to instruments needed with the preface that this "one tray" would provide the rapid sterilization to terminally sterilize with in the regulatory guidelines in a pre-vacuum cycle in 4 minutes. This is completed by a filtered vent and the thermodynamic behavior of steam. These filters are labeled as hydrophobic- meaning water is to bead on them and not go through them. These filters are a one time use and are changed with each process. It was our experience that the filters had not been hydrophobic. There was apparent water at the bottom of the tray. Manufacturer response for sealed sterilization container, one tray (per site reporter): the representative came to the o. R. And watch a cycle run. Everything that staff did was appropriate and to the manufacturer's recommendations. They had suggested that this was possible due to our water quality. The same testing was completed with sterile water and it resulted in the same defect.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number6590316
MDR Report Key6590316
Date Received2017-05-25
Date of Report2017-05-08
Date of Event2017-04-26
Report Date2017-05-05
Date Reported to FDA2017-05-05
Date Reported to Mfgr2017-05-05
Date Added to Maude2017-05-25
Event Key0
Report Source CodeUser Facility report
Manufacturer LinkN
Number of Patients in Event0
Adverse Event Flag0
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameONE TRAY
Generic NameSTERILIZATION WRAP CONTAINERS, TRAYS, CASSETTES & OTHER ACCESSORIES
Product CodeKCT
Date Received2017-05-25
Lot Number85280, 84997, 85289, 85894
ID NumberKIT NUMBER: K02170429
Device AvailabilityN
Device Age14 DY
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerINNOVATIVE STERILIZATION TECHNOLOGIES LLC
Manufacturer Address7625 PARAGON RD. STE. A DAYTON OH 45459 US 45459