UNKNOWN

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed with the FDA on 2017-06-02 for UNKNOWN manufactured by Cook Endoscopy.

Event Text Entries

[76725419] Investigation evaluation: a product evaluation was not performed in response to this report because the product said to be involved was not provided to cook for evaluation. The report could not be confirmed. A review of the device history record could not be conducted because the lot number was not provided. Investigation conclusion: we could not conduct a complete investigation because the product said to be involved was not returned for evaluation. A definitive cause for the reported observation could not be determined. The size of tissue sample or biopsy to be excised can be controlled by how the user handles the forceps. If excessive pressure was applied during advancement into the tissue or during handle manipulation, this could have contributed to the reported observation. The instructions for use direct the user to advance the forceps into the tissue at the desired biopsy site. Then the user is instructed to close the forceps around the tissue while using slight pressure on the handle. The user is instructed to maintain gentle handle pressure to keep the cups closed and gently withdraw the forceps from the site. The instructions for use under the warnings section states: "these single-use forceps should only be used to biopsy tissue where possible bleeding or hemorrhage will not present a danger for patients. Adequate plans for management of potential bleeding or hemorrhage and appropriate airway management should be in place. " the instructions for use lists potential complications as: "those associated with gastrointestinal endoscopy include but are not limited to: perforation, bleeding or hemorrhage, aspiration, fever, infection, allergic reaction to medication, hypotension, respiratory depression or arrest, cardiac arrhythmia or arrest. " prior to distribution, all captura disposable biopsy forceps are subjected to a visual inspection to ensure device integrity. Corrective action: a review of the complaint history was conducted. The likelihood of occurrence is considered rare. Corrective action is not warranted at this time based on the quality engineering risk assessment. Quality assurance will continue to monitor for complaint trends and reassess the risk assessment results as post market feedback continues to become available.
Patient Sequence No: 1, Text Type: N, H10


[76725420] During multiple biopsy procedures, the physician used a cook biopsy forcep (unknown model). The user claims that "every once in a while, there is bleeding post biopsy".
Patient Sequence No: 1, Text Type: D, B5


[81176209] Investigation evaluation: a product evaluation was not performed in response to this report because the product said to be involved was not provided to cook for evaluation. The report could not be confirmed. A review of the device history record could not be conducted because the lot number was not provided. Investigation conclusion: we could not conduct a complete investigation because the product said to be involved was not returned for evaluation. A definitive cause for the reported observation could not be determined. The size of tissue sample or biopsy to be excised can be controlled by how the user handles the forceps. If excessive pressure was applied during advancement into the tissue or during handle manipulation, this could have contributed to the reported observation. The instructions for use direct the user to advance the forceps into the tissue at the desired biopsy site. Then the user is instructed to close the forceps around the tissue while using slight pressure on the handle. The user is instructed to maintain gentle handle pressure to keep the cups closed and gently withdraw the forceps from the site. The instructions for use under the warnings section states: "these single-use forceps should only be used to biopsy tissue where possible bleeding or hemorrhage will not present a danger for patients. Adequate plans for management of potential bleeding or hemorrhage and appropriate airway management should be in place. " the instructions for use lists potential complications as: "those associated with gastrointestinal endoscopy include but are not limited to: perforation, bleeding or hemorrhage, aspiration, fever, infection, allergic reaction to medication, hypotension, respiratory depression or arrest, cardiac arrhythmia or arrest. " prior to distribution, all captura disposable biopsy forceps are subjected to a visual inspection to ensure device integrity. Corrective action: a review of the complaint history was conducted. The likelihood of occurrence is considered rare. Corrective action is not warranted at this time based on the quality engineering risk assessment. Quality assurance will continue to monitor for complaint trends and reassess the risk assessment results as post market feedback continues to become available.
Patient Sequence No: 1, Text Type: N, H10


[81176210] During multiple biopsy procedures, the physician used a cook biopsy forcep (unknown model). The user claims that "every once in a while, there is bleeding post biopsy".
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number1037905-2017-00338
MDR Report Key6608460
Date Received2017-06-02
Date of Report2017-06-08
Date Mfgr Received2017-05-30
Date Added to Maude2017-06-02
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. SCOTTIE FARIOLE
Manufacturer Street4900 BETHANIA STATION RD
Manufacturer CityWINSTON-SALEM NC 27105
Manufacturer CountryUS
Manufacturer Postal27105
Manufacturer Phone3367440157
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameUNKNOWN
Product CodeNON
Date Received2017-06-02
Catalog NumberUNKNOWN
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device AgeDA
Device Eval'ed by Mfgr*
Device Sequence No1
Device Event Key0
ManufacturerCOOK ENDOSCOPY
Manufacturer Address4900 BETHANIA STATION RD WINSTON-SALEM NC 27105 US 27105


Patients

Patient NumberTreatmentOutcomeDate
10 2017-06-02

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.