IMMUNOSORBA COLUMN 9797200

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a 01,05 report with the FDA on 2006-02-06 for IMMUNOSORBA COLUMN 9797200 manufactured by Fresenius Hemocare.

Event Text Entries

[16824524] A pt with morbus wegener (medical condition) and resulting renal failure received 10 immunosorba (ia) treatments for three months in 2002 with one pair of ia columns. Pt responded well to treatment but developed elevated mercury, 305 ug/l after 9th treatment with symptoms of tremor, weakness, unclear speech, poor memory, dyspnea, dizziness and aggressiveness. The pt was admitted to a "detoxification center. " his hg level at discharge was 20 ug/l. Adverse event occurred outside the united states.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3033270-2006-00003
MDR Report Key671424
Report Source01,05
Date Received2006-02-06
Date of Report2006-02-03
Date of Event2002-05-07
Report Date2006-02-03
Date Mfgr Received2003-03-31
Date Added to Maude2006-02-07
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactJOSHUA LASKER
Manufacturer Street14715 NE 95TH ST, STE 100
Manufacturer CityREDMOND WA 98052
Manufacturer CountryUS
Manufacturer Postal98052
Manufacturer Phone4252422154
Manufacturer G1*
Manufacturer Street*
Manufacturer City*
Manufacturer Country*
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameIMMUNOSORBA COLUMN
Generic NameIMMUNOADSORPTION COLUMN
Product CodeLQQ
Date Received2006-02-06
Model Number9797200
Catalog Number9797200
Lot NumberC1051-3-4
ID NumberNA
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device AgeUNK
Device Eval'ed by MfgrN
Implant FlagN
Date RemovedA
Device Sequence No1
Device Event Key660746
ManufacturerFRESENIUS HEMOCARE
Manufacturer Address* REDMOND WA * US
Baseline Brand NameIMMUNOSORBA COLUMN
Baseline Generic NameIMMUNOADSORPTION SYSTEM
Baseline Catalog No9797200
Baseline Device FamilyIMMUNOADSORPTION COLUMN
Baseline Shelf Life ContainedY
Baseline Shelf Life [Months]12
Baseline PMA FlagN
Baseline 510K PMNN
Baseline PreamendmentN
Baseline TransitionalN
510k ExemptN


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2006-02-06

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.