MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a foreign,health professional,u report with the FDA on 2017-08-18 for COBAS 6000 E 601 MODULE E601 04745922001 manufactured by Roche Diagnostics.
[83749868]
Unique identifier (udi)#: (b)(4). This event occurred in (b)(6).
Patient Sequence No: 1, Text Type: N, H10
[83749869]
The customer received questionable low elecsys total psa immunoassay and free psa results for one patient sample. The initial total psa result was 0. 681 ug/l and free psa result was 0. 311 ug/l. The same sample was repeated on (b)(6) 2017. The total psa result was 9. 91 ug/l with a data flag and the free psa result was 0. 600 ug/l. A new sample was drawn from the patient and the total psa result was 10. 59 ug/l and free psa result was 0. 671 ug/l. The erroneous result was not reported outside the laboratory. There was no allegation of an adverse event. The total psa reagent lot number was 19942201 and free psa reagent lot number was 209877. The expiration dates were requested but were not provided. A specific root cause could not be determined. A typical cause for low result is a sample pipetting issue. Review of the provided analyzer alarm trace found a few sample pipetting alarms. The field service representative checked the analyzer and preanalytics.
Patient Sequence No: 1, Text Type: D, B5
Report Number | 1823260-2017-01745 |
MDR Report Key | 6803075 |
Report Source | FOREIGN,HEALTH PROFESSIONAL,U |
Date Received | 2017-08-18 |
Date of Report | 2017-10-09 |
Date of Event | 2017-06-29 |
Date Mfgr Received | 2017-07-30 |
Date Added to Maude | 2017-08-18 |
Event Key | 0 |
Report Source Code | Manufacturer report |
Manufacturer Link | Y |
Number of Patients in Event | 0 |
Adverse Event Flag | 0 |
Product Problem Flag | 3 |
Reprocessed and Reused Flag | 3 |
Health Professional | 3 |
Initial Report to FDA | 3 |
Report to FDA | 3 |
Event Location | 3 |
Manufacturer Contact | NA MICHAEL LESLIE |
Manufacturer Street | 9115 HAGUE ROAD NA |
Manufacturer City | INDIANAPOLIS IN 46250 |
Manufacturer Country | US |
Manufacturer Postal | 46250 |
Manufacturer Phone | 3175214343 |
Manufacturer G1 | HITACHI HIGH TECH CORP. |
Manufacturer Street | 882 ICHIGE HITACHINAKA NA |
Manufacturer City | IBARAKI 312-8504 |
Manufacturer Country | JA |
Manufacturer Postal Code | 312-8504 |
Single Use | 3 |
Previous Use Code | 3 |
Removal Correction Number | NA |
Event Type | 3 |
Type of Report | 3 |
Brand Name | COBAS 6000 E 601 MODULE |
Generic Name | IMMUNOCHEMISTRY ANALYZER |
Product Code | LTJ |
Date Received | 2017-08-18 |
Model Number | E601 |
Catalog Number | 04745922001 |
Lot Number | NA |
ID Number | NA |
Operator | HEALTH PROFESSIONAL |
Device Availability | Y |
Device Age | DA |
Device Eval'ed by Mfgr | R |
Device Sequence No | 0 |
Device Event Key | 0 |
Manufacturer | ROCHE DIAGNOSTICS |
Manufacturer Address | 9115 HAGUE ROAD NA INDIANAPOLIS IN 462500457 US 462500457 |
Brand Name | COBAS 6000 E 601 MODULE |
Generic Name | IMMUNOCHEMISTRY ANALYZER |
Product Code | JJE |
Date Received | 2017-08-18 |
Model Number | E601 |
Catalog Number | 04745922001 |
Lot Number | NA |
ID Number | NA |
Operator | HEALTH PROFESSIONAL |
Device Availability | Y |
Device Age | DA |
Device Eval'ed by Mfgr | R |
Device Sequence No | 1 |
Device Event Key | 0 |
Manufacturer | ROCHE DIAGNOSTICS |
Manufacturer Address | 9115 HAGUE ROAD NA INDIANAPOLIS IN 462500457 US 462500457 |
Patient Number | Treatment | Outcome | Date |
---|---|---|---|
1 | 0 | 2017-08-18 |